{"product_id":"tc-odk161-digital-output-module-honeywell","title":"TC-ODK161 Digital Output Module Honeywell","description":"\u003ch2\u003eHoneywell TC-ODK161 Rev G0 AC Digital Output Module\u003c\/h2\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eManufacturer:\u003c\/span\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eModel Number:\u003c\/span\u003e TC-ODK161 Rev G0\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eProduct Type:\u003c\/span\u003e Experion AC Digital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eOutput Channels:\u003c\/span\u003e 16 isolated AC output channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eOutput Voltage:\u003c\/span\u003e 120V AC nominal operating voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eVoltage Range:\u003c\/span\u003e 0-132V AC operating range\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eCurrent Rating:\u003c\/span\u003e 2A maximum per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eTotal Module Current:\u003c\/span\u003e 16A maximum combined load\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eFrequency Range:\u003c\/span\u003e 47-63 Hz AC frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eOutput Type:\u003c\/span\u003e Solid-state relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eResponse Time:\u003c\/span\u003e 20ms maximum update rate\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eOn-State Voltage Drop:\u003c\/span\u003e 1.6V maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eOff-State Leakage:\u003c\/span\u003e 5mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eIsolation Rating:\u003c\/span\u003e 1500V RMS channel-to-system isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eSurge Protection:\u003c\/span\u003e 1000V peak surge withstand\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003ePower Consumption:\u003c\/span\u003e 8W maximum power dissipation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eOperating Temperature:\u003c\/span\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eStorage Temperature:\u003c\/span\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eHumidity Rating:\u003c\/span\u003e 5-95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3366ff;\"\u003eHeat Dissipation:\u003c\/span\u003e 27 BTU\/hour maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in compatible Honeywell Experion C200\/C300 chassis\u003c\/li\u003e\n\u003cli\u003eUse appropriate 20-position terminal blocks for output wiring\u003c\/li\u003e\n\u003cli\u003eMaintain minimum 50mm clearance for proper heat dissipation\u003c\/li\u003e\n\u003cli\u003eFollow NEC wiring requirements for AC power circuits\u003c\/li\u003e\n\u003cli\u003eEnsure proper fusing and circuit protection for each channel\u003c\/li\u003e\n\u003cli\u003eVerify all load wiring meets local electrical codes\u003c\/li\u003e\n\u003cli\u003eTest each output channel functionality during commissioning\u003c\/li\u003e\n\u003cli\u003eCheck heat sink mounting for proper thermal transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eHoneywell TC-ODK161 Rev G0\u003c\/strong\u003e AC output module\u003c\/li\u003e\n\u003cli\u003eInstallation and configuration manual\u003c\/li\u003e\n\u003cli\u003eCertified calibration documentation\u003c\/li\u003e\n\u003cli\u003eSafety and compliance certificates\u003c\/li\u003e\n\u003cli\u003eMounting hardware and installation guide\u003c\/li\u003e\n\u003cli\u003eExpress shipping via DHL, FedEx, or UPS services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16-channel AC output control capability\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade 120V AC, 2A per channel rating\u003c\/li\u003e\n\u003cli\u003eRapid 20ms response time for real-time control\u003c\/li\u003e\n\u003cli\u003eSolid-state relay outputs for long service life\u003c\/li\u003e\n\u003cli\u003e1500V RMS isolation for safety and noise immunity\u003c\/li\u003e\n\u003cli\u003eBuilt-in surge protection for reliability\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range for harsh environments\u003c\/li\u003e\n\u003cli\u003eEfficient heat dissipation design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical specifications and purchasing information about the \u003cstrong\u003eHoneywell TC-ODK161 Rev G0\u003c\/strong\u003e, please contact: \u003cstrong\u003e\u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45232835395745,"sku":"TC-ODK161","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/TC-ODD321_2_4674ec73-2a84-4047-8caa-c6a488873e45.jpg?v=1761098060","url":"https:\/\/www.autonexcontrol.com\/th\/products\/tc-odk161-digital-output-module-honeywell","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}