{"product_id":"lenze-emb9352-c-inverter-braking-module","title":"Lenze EMB9352-C Inverter Braking Module","description":"\u003ch2\u003e\u003cstrong\u003eProduct Introduction: Lenze EMB9352-C Inverter Braking Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eEMB9352-C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e Series 9300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e270 to 775 Volts DC\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Braking Power:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e25 kW at 765V DC\u003c\/strong\u003e\u003c\/span\u003e (12 kW at 375V, 23 kW at 725V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Braking Power:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e11 kW at 765V DC\u003c\/strong\u003e\u003c\/span\u003e (5 kW at 375V, 10 kW at 725V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e32 Amperes\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Thresholds:\u003c\/strong\u003e 375V DC, 725V DC, 726V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBraking Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e47 ohms minimum\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Tolerance \u0026amp; Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 40°C (full power), -40 to 50°C (with derating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -25 to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Tolerance:\u003c\/strong\u003e Up to \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e85% relative humidity\u003c\/strong\u003e\u003c\/span\u003e, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e Up to \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e0.7G\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20 (against touch and solid objects)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LED status indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the main function of the Lenze EMB9352-C?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It is a braking module that safely dissipates excess regenerative energy from a motor drive, protecting the inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum DC voltage required for it to operate?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module starts functioning at \u003cstrong\u003e270 Volts DC\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use a single braking resistor with this module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, you must connect an external resistor with a \u003cstrong\u003eminimum of 47 ohms\u003c\/strong\u003e resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How is the module installed?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Installation is simple using the integrated \u003cstrong\u003eDIN rail mount\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What do the different power ratings (peak vs. continuous) mean?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e \u003cstrong\u003ePeak power\u003c\/strong\u003e (e.g., 25kW) is for short-term braking. \u003cstrong\u003eContinuous power\u003c\/strong\u003e (e.g., 11kW) is the safe level for prolonged operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information:\u003c\/strong\u003e\u003cbr\u003eFor product inquiries and pricing: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003eFor instant support: \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e (WhatsApp)\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":45664843268257,"sku":"EMB9352-C","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/EMB9352-C.jpg?v=1769154718","url":"https:\/\/www.autonexcontrol.com\/th\/products\/lenze-emb9352-c-inverter-braking-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}