{"product_id":"ge-fanuc-ic670alg330-output-module","title":"GE Fanuc IC670ALG330 Output Module","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc Field Control \u003cspan style=\"color: #2e86c1;\"\u003eIC670ALG330\u003c\/span\u003e Analog Current Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Manufacturer:\u003c\/strong\u003e GE Fanuc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries \u0026amp; Model:\u003c\/strong\u003e Field Control series, model \u003cstrong\u003e\u003cspan style=\"color: #2e86c1;\"\u003eIC670ALG330\u003c\/span\u003e\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 8-channel single-ended analog current-source output module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal \u0026amp; Range:\u003c\/strong\u003e \u003cspan style=\"color: #28b463;\"\u003e0-20 mA\u003c\/span\u003e standard, up to 0-20.48 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e High-fidelity \u003cspan style=\"color: #28b463;\"\u003e16-bit\u003c\/span\u003e Digital-to-Analog Converter (DAC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Resolution:\u003c\/strong\u003e Fine control at \u003cspan style=\"color: #28b463;\"\u003e0.3125 µA per count\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Time:\u003c\/strong\u003e Fast channel update of \u003cspan style=\"color: #28b463;\"\u003e1.5 milliseconds\u003c\/span\u003e, typical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e Excellent accuracy within \u003cspan style=\"color: #28b463;\"\u003e1 LSB (Least Significant Bit)\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e Eight (8) current source outputs in a single group.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Power Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e Requires \u003cspan style=\"color: #28b463;\"\u003e18-30 VDC\u003c\/span\u003e, 24 VDC nominal, with ≤10% ripple.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent from BIU:\u003c\/strong\u003e Draws a maximum of \u003cspan style=\"color: #28b463;\"\u003e85 mA\u003c\/span\u003e from the bus interface unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent from External Supply:\u003c\/strong\u003e Maximum \u003cspan style=\"color: #28b463;\"\u003e250 mA\u003c\/span\u003e (with all 8 outputs at 20mA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Load Limits:\u003c\/strong\u003e Max \u003cspan style=\"color: #28b463;\"\u003e2000 pF\u003c\/span\u003e capacitance and \u003cspan style=\"color: #28b463;\"\u003e0.5 H\u003c\/span\u003e inductance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Rating:\u003c\/strong\u003e High \u003cspan style=\"color: #28b463;\"\u003e1500 VAC for 1 minute\u003c\/span\u003e (ground to logic).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Isolation:\u003c\/strong\u003e Rated for \u003cspan style=\"color: #28b463;\"\u003e250 VAC continuous\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics \u0026amp; Functional Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Detection:\u003c\/strong\u003e Reports \u003cspan style=\"color: #28b463;\"\u003eunderrange, overrange, and open wire\u003c\/span\u003e conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Wire Threshold:\u003c\/strong\u003e Detects faults at \u003cspan style=\"color: #28b463;\"\u003e1.0 to 3.5 mA\u003c\/span\u003e output current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Hold State:\u003c\/strong\u003e Channels can be configured to hold the last value on fault (BIU reset, data timeout, power loss).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault State Resolution:\u003c\/strong\u003e Hold state resolution reduces from \u003cspan style=\"color: #28b463;\"\u003e16-bit to 14-bit\u003c\/span\u003e during power loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e User-calibratable; factory settings stored in onboard \u003cspan style=\"color: #28b463;\"\u003eflash memory\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Types:\u003c\/strong\u003e Supports \u003cspan style=\"color: #28b463;\"\u003ebit and word data types\u003c\/span\u003e for configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicator:\u003c\/strong\u003e Single LED shows status: Steady (OK), Flashing (Fault), Off (No Power\/Fatal Error).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many output channels does it have?\u003c\/strong\u003e\u003cbr\u003eA: It provides \u003cspan style=\"color: #28b463;\"\u003e8 independent 0-20 mA analog output channels\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is its output resolution and update speed?\u003c\/strong\u003e\u003cbr\u003eA: It features \u003cspan style=\"color: #28b463;\"\u003e16-bit resolution\u003c\/span\u003e and a fast \u003cspan style=\"color: #28b463;\"\u003e1.5 ms update time\u003c\/span\u003e per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it diagnose wiring problems?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Yes, it includes diagnostics for \u003cspan style=\"color: #28b463;\"\u003eopen wire detection\u003c\/span\u003e and output range faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What happens during a power or communication fault?\u003c\/strong\u003e\u003cbr\u003eA: Outputs can be set to \u003cspan style=\"color: #28b463;\"\u003ehold their last state\u003c\/span\u003e, though at a reduced 14-bit resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I recalibrate the module?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is user-calibratable, and calibration data is saved in non-volatile flash memory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What power supply is needed?\u003c\/strong\u003e\u003cbr\u003eA: An external \u003cspan style=\"color: #28b463;\"\u003e18-30 VDC, 24V nominal\u003c\/span\u003e supply with low ripple is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have stock and how do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We have limited legacy stock and \u003cstrong\u003eship within 5 days\u003c\/strong\u003e via \u003cstrong\u003eDHL, FedEx, or UPS\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We offer a \u003cstrong\u003e30-day return policy\u003c\/strong\u003e on all purchases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor sourcing the legacy \u003cstrong\u003eIC670ALG330\u003c\/strong\u003e module or technical support, please contact us. \u003cstrong\u003eContact:\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or call\/WhatsApp \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45477509562529,"sku":"IC670ALG330","price":219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC670ALG330.jpg?v=1764659399","url":"https:\/\/www.autonexcontrol.com\/th\/products\/ge-fanuc-ic670alg330-output-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}