{"product_id":"ge-fanuc-ic670alg240-analog-input-module","title":"GE Fanuc IC670ALG240 Analog Input Module","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc Field Control \u003cspan style=\"color: #2e86c1;\"\u003eIC670ALG240\u003c\/span\u003e 16-Channel Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Manufacturer:\u003c\/strong\u003e GE Fanuc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries \u0026amp; Model:\u003c\/strong\u003e Field Control series, model \u003cstrong\u003e\u003cspan style=\"color: #2e86c1;\"\u003eIC670ALG240\u003c\/span\u003e\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 16-channel single-ended analog current\/voltage source input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal \u0026amp; Range:\u003c\/strong\u003e Accepts standard \u003cspan style=\"color: #28b463;\"\u003e0-20 mA \/ 4-20 mA\u003c\/span\u003e, with an operational range up to 0-25 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Current:\u003c\/strong\u003e Handles up to \u003cspan style=\"color: #28b463;\"\u003e35 mA\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e High-precision \u003cspan style=\"color: #28b463;\"\u003e16-bit\u003c\/span\u003e Analog-to-Digital Converter (ADC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection (CMR):\u003c\/strong\u003e Excellent noise immunity at \u003cspan style=\"color: #28b463;\"\u003e86 dB\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Filter:\u003c\/strong\u003e Integrated \u003cspan style=\"color: #28b463;\"\u003e2nd order RC filter\u003c\/span\u003e for signal conditioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Grouping:\u003c\/strong\u003e All sixteen channels are in a \u003cspan style=\"color: #28b463;\"\u003esingle group\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent from BIU:\u003c\/strong\u003e Draws a maximum of \u003cspan style=\"color: #28b463;\"\u003e251 mA\u003c\/span\u003e from the bus interface unit power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Wiring Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Loop Power:\u003c\/strong\u003e Requires \u003cspan style=\"color: #28b463;\"\u003e20-28 VDC\u003c\/span\u003e, 24 VDC nominal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Ripple:\u003c\/strong\u003e Allows a maximum of \u003cspan style=\"color: #28b463;\"\u003e10%\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Wiring:\u003c\/strong\u003e Compatible with \u003cspan style=\"color: #28b463;\"\u003eANSI Type 2 (2-wire)\u003c\/span\u003e and \u003cspan style=\"color: #28b463;\"\u003eANSI Type 3 (3-wire)\u003c\/span\u003e transmitter configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Rating:\u003c\/strong\u003e High \u003cspan style=\"color: #28b463;\"\u003e1500 VAC for 1 minute\u003c\/span\u003e (ground to logic).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Isolation:\u003c\/strong\u003e Rated for \u003cspan style=\"color: #28b463;\"\u003e250 VAC continuous\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e Supports \u003cspan style=\"color: #28b463;\"\u003e50\/60 Hz\u003c\/span\u003e power systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental \u0026amp; Functional Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #28b463;\"\u003e0°C to 55°C\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics \u0026amp; Alarms:\u003c\/strong\u003e Comprehensive diagnostics include module calibration status, \u003cspan style=\"color: #28b463;\"\u003eover-range\/under-range\u003c\/span\u003e conditions, and channel-specific high\/low alarms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Module is user-calibratable, with calibration data stored in non-volatile flash memory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiltering Options:\u003c\/strong\u003e Offers configurable input, line, and averaging filters for signal stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Management:\u003c\/strong\u003e Includes a \u003cspan style=\"color: #28b463;\"\u003e\"Channel Active\" mode\u003c\/span\u003e to enable or disable individual channels as needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfacing with pressure, level, flow, and temperature transmitters.\u003c\/li\u003e\n\u003cli\u003eConnecting to panel meters, data loggers, and single-loop controllers.\u003c\/li\u003e\n\u003cli\u003eMonitoring analog outputs from Variable Frequency Drives (VFDs).\u003c\/li\u003e\n\u003cli\u003eIntegration with signal splitters, isolators, and other conditioning devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis module must be installed with a compatible GE Fanuc Bus Interface Unit (BIU) in an expansion rack.\u003c\/li\u003e\n\u003cli\u003eIt uses a \u003cspan style=\"color: #28b463;\"\u003ecommon power supply\u003c\/span\u003e for all 16 input loops.\u003c\/li\u003e\n\u003cli\u003eEnsure the external 24V DC power supply meets the ripple specification for accurate readings.\u003c\/li\u003e\n\u003cli\u003eUtilize the supported ANSI wiring standards for proper transmitter connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the condition of the \u003cstrong\u003eIC670ALG240\u003c\/strong\u003e module?\u003c\/strong\u003e\u003cbr\u003eA: We supply \u003cstrong\u003enew and original\u003c\/strong\u003e \u003cstrong\u003eIC670ALG240\u003c\/strong\u003e modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many input channels does it have?\u003c\/strong\u003e\u003cbr\u003eA: It is a high-density module with \u003cspan style=\"color: #28b463;\"\u003e16 single-ended analog input channels\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is its measurement resolution?\u003c\/strong\u003e\u003cbr\u003eA: It provides high-accuracy conversion with \u003cspan style=\"color: #28b463;\"\u003e16-bit resolution\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it support 2-wire and 3-wire transmitters?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports both \u003cspan style=\"color: #28b463;\"\u003eANSI Type 2 (2-wire)\u003c\/span\u003e and \u003cspan style=\"color: #28b463;\"\u003eType 3 (3-wire)\u003c\/span\u003e transmitter wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the common mode rejection capability?\u003c\/strong\u003e\u003cbr\u003eA: It features an excellent \u003cspan style=\"color: #28b463;\"\u003e86 dB common mode rejection ratio (CMRR)\u003c\/span\u003e for noise immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I disable individual channels?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cspan style=\"color: #28b463;\"\u003e\"Channel Active\" mode\u003c\/span\u003e allows you to individually enable or disable any channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is calibration data retained?\u003c\/strong\u003e\u003cbr\u003eA: Yes, calibration data is stored in the module's \u003cspan style=\"color: #28b463;\"\u003eflash memory\u003c\/span\u003e and is not lost during power cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have stock and how fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We have this module in stock and typically \u003cstrong\u003eship within 5 business days\u003c\/strong\u003e via \u003cstrong\u003eDHL, FedEx, or UPS\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We offer a \u003cstrong\u003e30-day return policy\u003c\/strong\u003e for your convenience, subject to standard terms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more information or to purchase the GE Fanuc \u003cstrong\u003eIC670ALG240\u003c\/strong\u003e module, please contact our sales team. \u003cstrong\u003eContact:\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or call\/WhatsApp \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45477500387489,"sku":"IC670ALG240","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC670ALG240.jpg?v=1764659076","url":"https:\/\/www.autonexcontrol.com\/th\/products\/ge-fanuc-ic670alg240-analog-input-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}