{"product_id":"ge-fanuc-emerson-ic697bem731-bus-transmitter-module","title":"GE Fanuc Emerson IC697BEM731 Bus Transmitter Module","description":"\u003ch2\u003eGE Fanuc IC697BEM731 Genius I\/O Bus Controller Module\u003c\/h2\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: \u003cstrong\u003eGE Fanuc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003eIC697BEM731\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: \u003cspan style=\"color: green;\"\u003e5.0 VDC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eBackplane Current: \u003cspan style=\"color: green;\"\u003e1.3 Amps\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eCommunication Speed: \u003cspan style=\"color: green;\"\u003e153.5K, 76.8K, 38.4K Baud\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eBus Channels: \u003cspan style=\"color: green;\"\u003e1 Genius I\/O Port\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMonitor Port: \u003cspan style=\"color: green;\"\u003e1 HHM Port\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum Devices: \u003cspan style=\"color: green;\"\u003e30 nodes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eCable Type: Belden 9182 or GE IC660BLC001\/003\u003c\/li\u003e\n\u003cli\u003eCable Length: 2000 to 7500 feet (speed dependent)\u003c\/li\u003e\n\u003cli\u003eTermination: 75 or 150 Ohm resistors (IC660BLM506\/508)\u003c\/li\u003e\n\u003cli\u003ePhysical Size: Single slot design\u003c\/li\u003e\n\u003cli\u003eModule Weight: 2.0 pounds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree selectable baud rates for flexibility\u003c\/li\u003e\n\u003cli\u003eSupport for extensive device networks\u003c\/li\u003e\n\u003cli\u003eLong-distance communication capability\u003c\/li\u003e\n\u003cli\u003eStandard Genius I\/O protocol\u003c\/li\u003e\n\u003cli\u003eDedicated handheld monitor port\u003c\/li\u003e\n\u003cli\u003eRobust industrial communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in any available single slot\u003c\/li\u003e\n\u003cli\u003eUse recommended Belden 9182 cable\u003c\/li\u003e\n\u003cli\u003eProperly terminate bus with end resistors\u003c\/li\u003e\n\u003cli\u003eConfigure appropriate baud rate\u003c\/li\u003e\n\u003cli\u003eVerify maximum device count compliance\u003c\/li\u003e\n\u003cli\u003eCheck cable length for selected speed\u003c\/li\u003e\n\u003cli\u003eEnsure proper power supply capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelect baud rate based on application needs\u003c\/li\u003e\n\u003cli\u003eCalculate maximum cable length for speed\u003c\/li\u003e\n\u003cli\u003eChoose appropriate termination resistors\u003c\/li\u003e\n\u003cli\u003ePlan device layout within limits\u003c\/li\u003e\n\u003cli\u003eConfigure network addressing properly\u003c\/li\u003e\n\u003cli\u003eVerify communication with all devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Areas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFactory automation systems\u003c\/li\u003e\n\u003cli\u003eProcess control networks\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O systems\u003c\/li\u003e\n\u003cli\u003eMachine control applications\u003c\/li\u003e\n\u003cli\u003eIndustrial monitoring systems\u003c\/li\u003e\n\u003cli\u003ePlant-wide control networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eHow many devices can this controller support?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIC697BEM731\u003c\/strong\u003e supports up to \u003cspan style=\"color: green;\"\u003e30 devices\u003c\/span\u003e on the Genius I\/O bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat communication speeds are available?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIt offers \u003cspan style=\"color: green;\"\u003e153.5K, 76.8K, and 38.4K baud\u003c\/span\u003e rates for different applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat power does the module require?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIt operates on \u003cspan style=\"color: green;\"\u003e5.0 VDC\u003c\/span\u003e and draws \u003cspan style=\"color: green;\"\u003e1.3A\u003c\/span\u003e from the backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is the maximum cable length?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCable length ranges from 2000 to 7500 feet depending on selected baud rate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat termination is required?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse 75 or 150 Ohm end resistors (IC660BLM506\/508) for proper bus termination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat cable should I use?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended cable is Belden 9182 or equivalent GE IC660BLC001\/003.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHow much space does it need?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe module uses a single slot in the Series 90-70 rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact us for technical specifications and pricing: \u003cstrong\u003e\u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139252969633,"sku":"IC697BEM731","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC697BEM731-2.jpg?v=1761633763","url":"https:\/\/www.autonexcontrol.com\/th\/products\/ge-fanuc-emerson-ic697bem731-bus-transmitter-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}