{"product_id":"ci873a-communication-interface-ac-800m-abb","title":"CI873A Communication Interface | AC 800M ABB","description":"\u003ch2\u003e\u003cstrong\u003eCI873A EtherNet\/IP Communication Interface\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eCI873A\u003c\/strong\u003e from ABB enables AC 800M controllers to communicate with industrial devices using EtherNet\/IP protocol. This versatile communication interface supports both EtherNet\/IP and DeviceNet protocols for flexible integration. It provides reliable connectivity for industrial automation and control systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProtocol and Communication Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplements \u003cspan style=\"color: #2c3e50;\"\u003eEtherNet\/IP protocol\u003c\/span\u003e for industrial Ethernet communication\u003c\/li\u003e\n\u003cli\u003eSupports DeviceNet protocol for additional connectivity options\u003c\/li\u003e\n\u003cli\u003eOperates as a master controller in industrial network applications\u003c\/li\u003e\n\u003cli\u003eUses CH1 Ethernet connector supporting 100 Mbps transmission speed\u003c\/li\u003e\n\u003cli\u003eEnables communication with various industrial Ethernet devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e CI873A (Article 3BSE092695R1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e EtherNet\/IP and DeviceNet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation Mode:\u003c\/strong\u003e Master controller functionality\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Speed:\u003c\/strong\u003e 10\/100 Mbit\/s auto-negotiating Ethernet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Connector:\u003c\/strong\u003e RJ-45 female (8-pin) on TP867 baseplate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum CEX Bus Units:\u003c\/strong\u003e 12 modules per controller system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 160 mA typical at 24V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Requirements and Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRequires System 800xA version 6.0.3.3, 6.1.1 or later\u003c\/li\u003e\n\u003cli\u003eCompatible with HI Controller systems for industrial applications\u003c\/li\u003e\n\u003cli\u003eTP867 baseplate provides two RJ45 connectors (CH1 used for communication)\u003c\/li\u003e\n\u003cli\u003eContains CEX-Bus logic, communication unit, and DC\/DC converter\u003c\/li\u003e\n\u003cli\u003ePowered by +24V supply through the CEX-Bus connection\u003c\/li\u003e\n\u003cli\u003eSupports up to 6 redundant pairs of CI873A modules from version 5.1 FP4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance and Reliability Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports \u003cspan style=\"color: #27ae60;\"\u003emodule redundancy\u003c\/span\u003e for high-availability applications\u003c\/li\u003e\n\u003cli\u003eEnables \u003cspan style=\"color: #27ae60;\"\u003ehot swap capability\u003c\/span\u003e for maintenance without system interruption\u003c\/li\u003e\n\u003cli\u003eProvides robust EtherNet\/IP master functionality\u003c\/li\u003e\n\u003cli\u003eAllows configuration of up to 6 redundant module pairs\u003c\/li\u003e\n\u003cli\u003eDesigned for reliable operation in demanding industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e +5 to +55 °C (+41 to +131 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to +70 °C (-40 to +158 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5 to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Altitude:\u003c\/strong\u003e 2000 meters according to IEC\/EN 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e Degree 2 per IEC\/EN 61131-2 standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20 according to EN60529, IEC 529\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Protection:\u003c\/strong\u003e G3 compliance to ISA 71.04\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE marked for European market compliance\u003c\/li\u003e\n\u003cli\u003eUL 61010-1 and UL 61010-2-201 for electrical safety\u003c\/li\u003e\n\u003cli\u003eHazardous location certification: UL 60079-15, cULus Class 1, Zone 2\u003c\/li\u003e\n\u003cli\u003eAEx nA IIC T4, ExnA IIC T4Gc X for explosive atmospheres\u003c\/li\u003e\n\u003cli\u003eMarine certificates: DNV-GL (with ABS, BV, LR pending)\u003c\/li\u003e\n\u003cli\u003eRoHS compliance: DIRECTIVE\/2011\/65\/EU (EN 50581:2012)\u003c\/li\u003e\n\u003cli\u003eWEEE compliance: DIRECTIVE\/2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 59 mm (2.3 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 185 mm (7.3 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 127.5 mm (5.0 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 700 g (1.5 pounds) including base unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module on TP867 baseplate in AC 800M controller rack\u003c\/li\u003e\n\u003cli\u003eConnect Ethernet cable from CH1 port to industrial network switch\u003c\/li\u003e\n\u003cli\u003eConfigure EtherNet\/IP parameters for master device operation\u003c\/li\u003e\n\u003cli\u003eSet up module redundancy pairs if required for critical applications\u003c\/li\u003e\n\u003cli\u003eVerify proper +24V power supply through CEX-Bus connection\u003c\/li\u003e\n\u003cli\u003eTest communication with EtherNet\/IP devices after installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat protocols does the CI873A support?\u003c\/strong\u003e It supports both EtherNet\/IP and DeviceNet protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many redundant pairs are supported?\u003c\/strong\u003e It supports up to 6 redundant pairs of CI873A modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating mode?\u003c\/strong\u003e It operates as a master controller in the network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat system software is required?\u003c\/strong\u003e It requires System 800xA version 6.0.3.3, 6.1.1 or later.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich Ethernet port is used?\u003c\/strong\u003e Only the CH1 port is used for EtherNet\/IP communication.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45280715374753,"sku":"CI873A","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/CI873A.jpg?v=1761642035","url":"https:\/\/www.autonexcontrol.com\/th\/products\/ci873a-communication-interface-ac-800m-abb","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}