{"product_id":"900g04-0101-honeywell-universal-digital-input-module","title":"900G04-0101 Honeywell Universal Digital Input Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell 900G04-0101 Universal AC\/DC Digital Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #d35400;\"\u003e900G04-0101\u003c\/strong\u003e is a versatile 16-channel Digital Input module for the \u003cstrong\u003eHoneywell HC900\u003c\/strong\u003e controller. It accepts a wide range of AC or DC field voltages, providing maximum flexibility for industrial signal interfacing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong style=\"color: #d35400;\"\u003e900G04-0101\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital Input (DI) Module, Universal AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs per Module:\u003c\/strong\u003e 16 Channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Individual Channel-to-Channel \u0026amp; Channel-to-Chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e Euro Style 36-Terminal Block Required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Status Indicator:\u003c\/strong\u003e Green LED per Channel (ON when energized)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Status LED:\u003c\/strong\u003e Green Blinking (Active Scan), Red (Fault)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Inversion:\u003c\/strong\u003e Supported in Controller Software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Externally Powered by Field Voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C (Standard HC900 Range)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAC Input Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 80 VAC to 264 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Voltage Rating:\u003c\/strong\u003e 264 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Frequency Range:\u003c\/strong\u003e 47 Hz to 63 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON Voltage Level:\u003c\/strong\u003e 75 VAC Minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF Voltage Level:\u003c\/strong\u003e 20 VAC Maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 48 kΩ Nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current (@120V AC, 60Hz):\u003c\/strong\u003e 1 mA Nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current (@240V AC, 50Hz):\u003c\/strong\u003e 2 mA Nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum ON Current:\u003c\/strong\u003e 0.3 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum OFF Current:\u003c\/strong\u003e 0.2 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF to ON Response Time:\u003c\/strong\u003e 6 ms + 1.5 Line Cycles Max.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON to OFF Response Time:\u003c\/strong\u003e 6 ms + 2 Line Cycles Max.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDC Input Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 80 VDC to 125 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Voltage Rating:\u003c\/strong\u003e 150 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON Voltage Level:\u003c\/strong\u003e 75 VDC Minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF Voltage Level:\u003c\/strong\u003e 30 VDC Maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 48 kΩ Nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current (@125V DC):\u003c\/strong\u003e 2 mA Nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum ON Current:\u003c\/strong\u003e 0.3 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum OFF Current:\u003c\/strong\u003e 0.2 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF to ON Response Time:\u003c\/strong\u003e 6 ms + 2 Line Cycles Max.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON to OFF Response Time:\u003c\/strong\u003e 6 ms + 2 Line Cycles Max.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModule Features \u0026amp; Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTrue universal input accepts both AC (80-264V) and DC (80-125V) signals on the same terminals.\u003c\/li\u003e\n\u003cli\u003eEach of the 16 channels is individually isolated from each other and from chassis ground (350V AC max).\u003c\/li\u003e\n\u003cli\u003eHigh input impedance (48kΩ) minimizes loading on the sensed circuit.\u003c\/li\u003e\n\u003cli\u003eWide voltage ranges accommodate global power standards and various industrial control voltages.\u003c\/li\u003e\n\u003cli\u003eIndividual per-channel LEDs provide immediate visual confirmation of the input state.\u003c\/li\u003e\n\u003cli\u003eRequires an external Euro style 36-terminal block for field wiring connections.\u003c\/li\u003e\n\u003cli\u003eIdeal for mixed signal environments or applications where sensor voltage type may change.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in a compatible Honeywell HC900 rack. The module is externally powered by the field voltage.\u003c\/li\u003e\n\u003cli\u003eUse the specified Euro style 36-terminal block (not included) for all field connections.\u003c\/li\u003e\n\u003cli\u003eEach input requires two terminals: connect the field voltage across them (polarity sensitive for DC).\u003c\/li\u003e\n\u003cli\u003eEnsure the applied voltage (AC or DC) is within the specified ranges for reliable operation.\u003c\/li\u003e\n\u003cli\u003eFor AC signals, frequency must be between 47-63 Hz.\u003c\/li\u003e\n\u003cli\u003eFollow all local electrical codes for the voltage level being used. Use appropriate wire gauges.\u003c\/li\u003e\n\u003cli\u003eIndividual channel isolation allows mixing of different voltage sources on the same module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor terminal block details or to order the \u003cstrong\u003eHoneywell 900G04-0101\u003c\/strong\u003e, contact our sales team.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact:\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@nex-auto.com\"\u003e\u003cstrong\u003esales@nex-auto.com\u003c\/strong\u003e\u003c\/a\u003e or WhatsApp \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e\u003cstrong\u003e+86 153 9242 9628\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003e\u003cstrong\u003eNexAuto Technology Limited\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e© 2026 \u003ca href=\"https:\/\/www.autonexcontrol.com\/\"\u003e\u003cstrong\u003eAutoNex Controls Limited\u003c\/strong\u003e\u003c\/a\u003e. All rights reserved.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45621643903137,"sku":"900G04-0101","price":330.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/900G04-0101.jpg?v=1767599134","url":"https:\/\/www.autonexcontrol.com\/th\/products\/900g04-0101-honeywell-universal-digital-input-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}