{"product_id":"safe-analog-output-module-2-channel-4-20ma-fc-sao-0220m","title":"Safe Analog Output Module | 2-Channel 4-20mA FC-SAO-0220M","description":"\u003ch2\u003eSAO-0220m Safe Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSAO-0220m\u003c\/strong\u003e delivers reliable two-channel analog output control for safety-critical applications. This module provides \u003cspan style=\"color: #ff0000;\"\u003egalvanic isolation\u003c\/span\u003e and comprehensive diagnostic testing for maximum system integrity.\u003c\/p\u003e\n\u003ch3\u003eKey Safety and Diagnostic Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Output Channels:\u003c\/strong\u003e Two independent 0(4)-20mA analog outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Complete isolation from 24VDC and 5VDC supplies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSMOD Protection:\u003c\/strong\u003e Secondary means of de-energizing for each output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Testing:\u003c\/strong\u003e Continuous monitoring of output values and crosstalk\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Approvals:\u003c\/strong\u003e CE, TUV, UL, CSA, FM certified for global use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWatchdog Function:\u003c\/strong\u003e Independent output deactivation capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e 4 TE, 3 HE space-saving form factor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegular Self-Testing:\u003c\/strong\u003e Automated verification of output accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Numbers:\u003c\/strong\u003e \u003cstrong\u003eFS-SAO-0220m\u003c\/strong\u003e, \u003cstrong\u003eFC-SAO-0220m\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 2 isolated analog current outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Range:\u003c\/strong\u003e 0-20mA or 4-20mA selectable operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e \u003cspan style=\"color: #ff0000;\"\u003e12-bit D\/A converter\u003c\/span\u003e for precise control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Current:\u003c\/strong\u003e \u0026lt; 0.05mA when de-energized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 30mA at 5VDC, 65mA at 24VDC base\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Load:\u003c\/strong\u003e +30mA at 24VDC per active output channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWatchdog Current:\u003c\/strong\u003e 0.5mA input for monitoring function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance and Environmental Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive Operation:\u003c\/strong\u003e 600Ω maximum loop resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 30VDC maximum for loop powering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassive Operation:\u003c\/strong\u003e 40VDC maximum external supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e ≤ 7.5V minimum for proper operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Capacitance:\u003c\/strong\u003e 100nF maximum for stable performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C industrial range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 10ms per channel for responsive control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% of full scale at 25°C ambient\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Mounting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount in standard control cabinet using 4 TE space requirement\u003c\/li\u003e\n\u003cli\u003eEnsure proper clearance for ventilation and maintenance access\u003c\/li\u003e\n\u003cli\u003eFollow local electrical codes for safety system installations\u003c\/li\u003e\n\u003cli\u003eUse appropriate wire gauges for current carrying capacity\u003c\/li\u003e\n\u003cli\u003eVerify all connections before applying system power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging and Shipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes one \u003cstrong\u003eSAO-0220m\u003c\/strong\u003e safe analog output module\u003c\/li\u003e\n\u003cli\u003eComplete mounting hardware and installation manual included\u003c\/li\u003e\n\u003cli\u003eStatic-protective packaging ensures component protection\u003c\/li\u003e\n\u003cli\u003eWorldwide shipping via FedEx, UPS, and DHL available\u003c\/li\u003e\n\u003cli\u003eProfessional packaging guarantees secure delivery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the difference between active and passive operation? Active mode provides loop power while passive uses external supply\u003c\/li\u003e\n\u003cli\u003eCan this module operate in hazardous locations? Yes, it carries FM and other certifications for hazardous areas\u003c\/li\u003e\n\u003cli\u003eWhat is the resolution of the analog output? The 12-bit D\/A converter provides high precision control\u003c\/li\u003e\n\u003cli\u003eHow does the SMOD feature enhance safety? It allows independent output de-energizing beyond normal controls\u003c\/li\u003e\n\u003cli\u003eWhat is the maximum update rate for output changes? The module updates each channel within 10 milliseconds typically\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AutoNex Controls Limited ","offers":[{"title":"Default Title","offer_id":45286130221217,"sku":"FC-SAO-0220M","price":247.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/FC-SAO-0220M.jpg?v=1761793015","url":"https:\/\/www.autonexcontrol.com\/sk\/products\/safe-analog-output-module-2-channel-4-20ma-fc-sao-0220m","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}