{"product_id":"reverse-mount-probe-330906-02-12-10-02-00-bently-nevada","title":"Reverse Mount Probe 330906-02-12-10-02-00 | Bently Nevada","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 3300 NSv Reverse Mount Proximity Probe\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Bently Nevada \u003cstrong\u003e3300 NSv\u003c\/strong\u003e Series Probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003e330906-02-12-10-02-00\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Range:\u003c\/strong\u003e \u003cspan style=\"color: #00008b;\"\u003e1.5 mm (60 mils)\u003c\/span\u003e for optimal signal linearity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e Operates from 0.25 to 1.75 mm (10 to 70 mils).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Gap:\u003c\/strong\u003e Set to \u003cspan style=\"color: #8b4513;\"\u003e1.0 mm (40 mils)\u003c\/span\u003e for standard operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #b22222;\"\u003e4.2 Ω ± 0.5 ohms\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e \u003cspan style=\"color: #006400;\"\u003e1.0 meter (39 inches)\u003c\/span\u003e with integrated cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Product Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOffers greater chemical resistance than the legacy 3300 RAM probe model.\u003c\/li\u003e\n\u003cli\u003eProvides a better side view than the older 3000-series 190 probe at identical gap settings.\u003c\/li\u003e\n\u003cli\u003eFeatures gold-plated ClickLoc connectors that lock securely to prevent disconnections.\u003c\/li\u003e\n\u003cli\u003eThe TipLoc manufacturing method creates an extremely strong bond between the tip and probe body.\u003c\/li\u003e\n\u003cli\u003eThis configuration has approvals marked as \u003cspan style=\"color: #8b0000;\"\u003e\"Not required\"\u003c\/span\u003e for general use applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Wiring Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Thread:\u003c\/strong\u003e Standard \u003cspan style=\"color: #003366;\"\u003e3\/8-24 UNF\u003c\/span\u003e thread.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e Miniature coaxial ClickLoc connector with standard cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Wire Size:\u003c\/strong\u003e \u003cspan style=\"color: #006400;\"\u003e0.2–1.5 mm² (16–24 AWG)\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith Ferrules:\u003c\/strong\u003e Use 0.25–0.75 mm² (18–23 AWG) wire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum System Cable Length:\u003c\/strong\u003e Up to \u003cspan style=\"color: #003366;\"\u003e305 meters (1000 feet)\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does \"approval not required\" mean for this probe?\u003c\/strong\u003e\u003cbr\u003eA: It indicates this specific part number is intended for general industrial use where specific agency certifications (like ATEX) are not mandated by the customer's site requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Why is the gold-plated connector important?\u003c\/strong\u003e\u003cbr\u003eA: Gold plating reduces contact resistance, minimizes corrosion, and ensures a stable electrical connection over the probe's lifetime, which is critical for accurate signal transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I cut and reterminate the 1.0-meter cable if it's too long?\u003c\/strong\u003e\u003cbr\u003eA: No, the cable is integrated and not designed for field termination. You must manage the excess length properly in the junction box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this probe compatible with all Bently Nevada 3300 monitor frames?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003e3300 NSv\u003c\/strong\u003e probe is designed to work seamlessly with standard Bently Nevada 3300 XL monitor systems when configured correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor in-depth electrical characteristics, temperature ratings, and installation drawings, please download the official documentation: \u003cstrong\u003e\u003ca href=\"https:\/\/ctrlnexus-auto.com\/wp-content\/uploads\/2025\/03\/3300-XL-NSv-Proximity-Transducer-System-Datasheet-147385-1.pdf\" target=\"_blank\"\u003e3300 XL NSv System Datasheet\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor Product Inquiries and Technical Support:\u003c\/strong\u003e\u003cbr\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eAuthorized Partner: \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45139286032545,"sku":"330906-02-12-10-02-00","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/330906-02-12-10-02-00.jpg?v=1767520046","url":"https:\/\/www.autonexcontrol.com\/sk\/products\/reverse-mount-probe-330906-02-12-10-02-00-bently-nevada","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}