{"product_id":"ic670alg620-ge-fanuc-input-module","title":"IC670ALG620 GE Fanuc Input Module","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc Field Control \u003cspan style=\"color: #2e86c1;\"\u003eIC670ALG620\u003c\/span\u003e RTD Temperature Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Manufacturer:\u003c\/strong\u003e GE Fanuc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries \u0026amp; Model:\u003c\/strong\u003e Field Control series, model \u003cstrong\u003e\u003cspan style=\"color: #2e86c1;\"\u003eIC670ALG620\u003c\/span\u003e\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 4-channel RTD (Resistance Temperature Detector) input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e Supports \u003cspan style=\"color: #28b463;\"\u003e3-wire and 4-wire\u003c\/span\u003e RTD sensors (Platinum, Nickel, Nickel\/Iron, Copper).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e Four (4) independent RTD input channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Resolution:\u003c\/strong\u003e High precision \u003cspan style=\"color: #28b463;\"\u003e15 bits plus sign\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance Measurement Ranges:\u003c\/strong\u003e User-selectable: \u003cspan style=\"color: #28b463;\"\u003e0 to 500 Ohms\u003c\/span\u003e or \u003cspan style=\"color: #28b463;\"\u003e0 to 3000 Ohms\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan Time:\u003c\/strong\u003e \u003cspan style=\"color: #28b463;\"\u003e210 ms at 60 Hz\u003c\/span\u003e \/ \u003cspan style=\"color: #28b463;\"\u003e230 ms at 50 Hz\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Mode Rejection:\u003c\/strong\u003e Excellent \u003cspan style=\"color: #28b463;\"\u003e60 dB at 50\/60 Hz\u003c\/span\u003e for noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Diagnostic Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Lead Resistance:\u003c\/strong\u003e Allows up to \u003cspan style=\"color: #28b463;\"\u003e5 Ohms per lead wire\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent from BIU:\u003c\/strong\u003e Draws a maximum of \u003cspan style=\"color: #28b463;\"\u003e190 mA\u003c\/span\u003e from the Bus Interface Unit power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Detection:\u003c\/strong\u003e Comprehensive diagnostics for \u003cspan style=\"color: #28b463;\"\u003eOpen RTD, Input Short, Under-range, Over-range, and High\/Low Alarms\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Sensitivity:\u003c\/strong\u003e \u003cspan style=\"color: #28b463;\"\u003e±0.004% of reading\u003c\/span\u003e \/ \u003cspan style=\"color: #28b463;\"\u003e±1.5mV per °C\u003c\/span\u003e (referred to input) from 0-60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indication:\u003c\/strong\u003e Single front-panel LED: On (Normal), Flashing (Fault), Off (No Power).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration \u0026amp; System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Method:\u003c\/strong\u003e Programmed via a handheld device connected to the main Bus Interface Unit (BIU).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Management:\u003c\/strong\u003e Unused channels can be set to \u003cspan style=\"color: #28b463;\"\u003e\"Inactive\"\u003c\/span\u003e status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Type Selection:\u003c\/strong\u003e Choose from pre-defined RTD tables stored in the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Architecture:\u003c\/strong\u003e Up to 8 Field Control modules (mix of types) can connect to a single BIU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Modules plug into an I\/O Terminal Block that connects to the BIU.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the condition of the \u003cstrong\u003eIC670ALG620\u003c\/strong\u003e module?\u003c\/strong\u003e\u003cbr\u003eA: We supply \u003cstrong\u003enew and original\u003c\/strong\u003e \u003cstrong\u003eIC670ALG620\u003c\/strong\u003e modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What types of RTD sensors does it support?\u003c\/strong\u003e\u003cbr\u003eA: It supports standard \u003cspan style=\"color: #28b463;\"\u003e3-wire and 4-wire\u003c\/span\u003e RTDs made of Platinum, Nickel, Copper, or Nickel\/Iron.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many temperature points can it monitor?\u003c\/strong\u003e\u003cbr\u003eA: It can monitor temperatures from \u003cspan style=\"color: #28b463;\"\u003efour independent RTD sensors\u003c\/span\u003e simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the measurement resolution?\u003c\/strong\u003e\u003cbr\u003eA: It provides high-resolution measurement with \u003cspan style=\"color: #28b463;\"\u003e15 bits plus sign\u003c\/span\u003e digital resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How does it handle electrical noise?\u003c\/strong\u003e\u003cbr\u003eA: It features excellent \u003cspan style=\"color: #28b463;\"\u003e60 dB Normal Mode Rejection\u003c\/span\u003e at 50\/60 Hz to filter out line noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What faults can it detect?\u003c\/strong\u003e\u003cbr\u003eA: It detects \u003cspan style=\"color: #28b463;\"\u003eopen sensor, short circuit, under\/over range, and configurable high\/low alarms\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How is it configured?\u003c\/strong\u003e\u003cbr\u003eA: Configuration is done via a \u003cspan style=\"color: #28b463;\"\u003ehandheld programmer\u003c\/span\u003e connected to the Bus Interface Unit (BIU).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have it in stock and how do you ship?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we have stock and \u003cstrong\u003eship within 5 business days\u003c\/strong\u003e via \u003cstrong\u003eDHL, FedEx, or UPS\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We offer a \u003cstrong\u003e30-day return policy\u003c\/strong\u003e for all products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical details or to order the GE Fanuc \u003cstrong\u003eIC670ALG620\u003c\/strong\u003e RTD module, please get in touch. \u003cstrong\u003eContact:\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or call\/WhatsApp \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45477528502433,"sku":"IC670ALG620","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC670ALG620.jpg?v=1764659722","url":"https:\/\/www.autonexcontrol.com\/sk\/products\/ic670alg620-ge-fanuc-input-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}