{"product_id":"ge-fanuc-ic693ptm101-power-transducer-module","title":"GE Fanuc IC693PTM101 Power Transducer Module","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC693PTM101 Power Transducer Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Manufacturer:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e \u003cstrong style=\"color: #d35400;\"\u003eIC693PTM101\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Series:\u003c\/strong\u003e Series 90-30 PLC Systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e10 to 120 V AC\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current Range:\u003c\/strong\u003e \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e0 to 7.5 A\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e35 to 70 Hz\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Resolution:\u003c\/strong\u003e High-accuracy \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e14-bit\u003c\/strong\u003e\u003c\/span\u003e conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Speed:\u003c\/strong\u003e \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e20 ms at 50 Hz\u003c\/strong\u003e\u003c\/span\u003e \/ \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e16.67 ms at 60 Hz\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Modes:\u003c\/strong\u003e Single-phase, Three-phase, and Synchro monitor modes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e1500 V\u003c\/strong\u003e\u003c\/span\u003e for safety and noise immunity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power:\u003c\/strong\u003e \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e5 V DC at 400 mA\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Power Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e4 Watts\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Interface Cable:\u003c\/strong\u003e \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003eIC693CBL340\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC Memory Allocation:\u003c\/strong\u003e %I (16 bits), %Q (16 bits), %AI (25 words), %AQ (2 words)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features and Measured Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure true RMS values for AC voltage and current with high precision.\u003c\/li\u003e\n\u003cli\u003eCalculate active power (kW), reactive power (kVAR), and apparent power (kVA).\u003c\/li\u003e\n\u003cli\u003eAccumulate energy totals for kilowatt-hours (kWH), kVARH, and kVAH.\u003c\/li\u003e\n\u003cli\u003eMonitor system power factor, line frequency, and phase relationships.\u003c\/li\u003e\n\u003cli\u003eSupport both Wye and Delta configurations for three-phase power systems.\u003c\/li\u003e\n\u003cli\u003eEnable critical load shedding and peak demand control strategies.\u003c\/li\u003e\n\u003cli\u003eProvide synchronization monitoring for generator-to-grid connections.\u003c\/li\u003e\n\u003cli\u003eIntegrate measurements directly into the Series \u003cstrong\u003e90-30\u003c\/strong\u003e CPU logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Wiring Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module installs directly into any compatible Series 90-30 PLC rack slot.\u003c\/li\u003e\n\u003cli\u003eYou must use the specified \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003eIC693CBL340\u003c\/strong\u003e\u003c\/span\u003e interface cable for signal connections.\u003c\/li\u003e\n\u003cli\u003eEnsure all power to the PLC rack and the measured circuit is turned off.\u003c\/li\u003e\n\u003cli\u003eConnect voltage and current inputs according to the selected system mode (single\/three-phase).\u003c\/li\u003e\n\u003cli\u003eAdhere to the \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e1500 V\u003c\/strong\u003e\u003c\/span\u003e isolation ratings and proper grounding practices.\u003c\/li\u003e\n\u003cli\u003eVerify that the input signals are within the rated voltage and current ranges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What electrical parameters can the IC693PTM101 measure?\u003c\/strong\u003e\u003cbr\u003eA: It measures voltage, current, kW, kVAR, kVA, energy, power factor, and frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the input voltage and current range?\u003c\/strong\u003e\u003cbr\u003eA: It accepts \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e10-120V AC\u003c\/strong\u003e\u003c\/span\u003e and \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003e0-7.5A\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which cable is required to connect this module?\u003c\/strong\u003e\u003cbr\u003eA: You need the \u003cspan style=\"color: #1a73e8;\"\u003e\u003cstrong\u003eIC693CBL340\u003c\/strong\u003e\u003c\/span\u003e interface cable for signal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can it monitor three-phase systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports three-phase monitoring for both Wye and Delta configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this a new, original GE Fanuc module?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply only \u003cstrong\u003enew, original\u003c\/strong\u003e GE Fanuc \u003cstrong\u003eIC693PTM101\u003c\/strong\u003e modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the shipping and return policy?\u003c\/strong\u003e\u003cbr\u003eA: We ship in 5 days via major carriers and offer a standard 30-day return window.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e For more details, email \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or message on \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003eWhatsApp: +86 153 9242 9628\u003c\/a\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139257262241,"sku":"IC693PTM101","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC693PTM101.jpg?v=1765442284","url":"https:\/\/www.autonexcontrol.com\/sk\/products\/ge-fanuc-ic693ptm101-power-transducer-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}