{"product_id":"144-202-000-136-vibro-meter-piezoelectric-accelerometer","title":"144-202-000-136 Vibro Meter | Piezoelectric Accelerometer","description":"\u003ch2\u003eVibro Meter 144-202-000-136 High-Performance Industrial Accelerometer\u003c\/h2\u003e\n\u003ch3\u003eCritical Performance Metrics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0.01 to 400 g peak\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003eOverload Protection:\u003c\/strong\u003e Withstands 500 g peak spikes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003eShock Survival:\u003c\/strong\u003e ≤1000 g peak (1 ms duration)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity Accuracy:\u003c\/strong\u003e ±1% in lower range, ±2% to 400 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransverse Sensitivity:\u003c\/strong\u003e ≤3% for precise directional measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e 10⁹ Ω minimum for signal integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Series:\u003c\/strong\u003e vibro meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Designation:\u003c\/strong\u003e \u003cstrong\u003e144-202-000-136\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity Rating:\u003c\/strong\u003e 100 pC\/g ±5% at 120 Hz reference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Coverage:\u003c\/strong\u003e 0.5 to 6000 Hz (±5% tolerance)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResonant Performance:\u003c\/strong\u003e \u0026gt;22 kHz nominal frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Operation:\u003c\/strong\u003e -55°C to +260°C continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Term Survival:\u003c\/strong\u003e -70°C to +280°C extreme limits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction \u0026amp; Durability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHermetically welded austenitic stainless-steel housing\u003c\/li\u003e\n\u003cli\u003eHeat-resistant stainless-steel protection hose system\u003c\/li\u003e\n\u003cli\u003eSymmetrical shear-mode polycrystalline sensing element\u003c\/li\u003e\n\u003cli\u003eInternal case insulation with differential output\u003c\/li\u003e\n\u003cli\u003eSealed assembly resistant to humidity and contaminants\u003c\/li\u003e\n\u003cli\u003eImpervious to oil, steam, and sea-salt atmospheres\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e None - self-generating sensing principle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Transmission:\u003c\/strong\u003e 2-pin insulated charge output system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Capacitance:\u003c\/strong\u003e 5000 pF pin to pin configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Capacitance:\u003c\/strong\u003e 105 pF\/m pin to pin characteristic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Electronics:\u003c\/strong\u003e IPC70x signal conditioner series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 10 pF pin to case ground capacitance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Austenitic stainless steel 1.4441\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Weight:\u003c\/strong\u003e 250 grams (sensor unit only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Specification:\u003c\/strong\u003e 135 g\/m with integral construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 20 meters continuous integral cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting System:\u003c\/strong\u003e Four M6 × 35 Allen screw points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Torque:\u003c\/strong\u003e 15 N•m nominal tightening specification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Flying leads for direct wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification Level:\u003c\/strong\u003e Ex version for explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Resistance:\u003c\/strong\u003e 100% RH impervious construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContaminant Protection:\u003c\/strong\u003e Dust, fungus, and sand resistant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Strain Sensitivity:\u003c\/strong\u003e 0.15 × 10−³ g\/µε at 250 µε\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Compensation:\u003c\/strong\u003e 0.25%\/°C to 0.1%\/°C gradient\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support \u0026amp; Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat industrial applications suit the 144-202-000-136?\u003c\/strong\u003e\u003cbr\u003eHeavy machinery monitoring, hazardous area vibration analysis, and extreme environment measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow does the 20-meter cable affect performance?\u003c\/strong\u003e\u003cbr\u003eThe integral low-noise cable maintains signal integrity over the full length with specified capacitance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat mounting accessories are required?\u003c\/strong\u003e\u003cbr\u003eFour M6 × 35 Allen screws and M4 spring-lock washers for secure installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the 144-202-000-136 handle high-temperature environments?\u003c\/strong\u003e\u003cbr\u003eYes, continuous operation to 260°C with short-term survival to 280°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat makes this Ex version different?\u003c\/strong\u003e\u003cbr\u003eCertified for potentially explosive atmospheres with enhanced safety features.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor detailed technical consultation contact:\u003c\/strong\u003e \u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/p\u003e","brand":"Vibro Meter","offers":[{"title":"Default Title","offer_id":45280440811681,"sku":"144-202-000-136","price":325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/444-281-000-111-1_4d4dff14-8a5a-4941-89f5-0a9b5c608449.jpg?v=1761552660","url":"https:\/\/www.autonexcontrol.com\/sk\/products\/144-202-000-136-vibro-meter-piezoelectric-accelerometer","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}