{"product_id":"mda90a-0020-503-x-s00-sew-eurodrive-single-axis-inverter-module","title":"MDA90A-0020-503-X-S00 SEW-EURODRIVE Single-Axis Inverter Module","description":"\u003ch2\u003e\u003cstrong\u003eMDA90A-0020-503-X-S00 SEW-EURODRIVE Single-Axis Inverter Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e SEW-EURODRIVE; \u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eMDA90A-0020-503-X-S00\u003c\/strong\u003e; \u003cstrong\u003eSeries:\u003c\/strong\u003e MOVIDRIVE® modular Single-Axis Module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output current:\u003c\/strong\u003e 2 A performance class, with \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e250% overload for up to 1 s\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC link rated voltage:\u003c\/strong\u003e DC 750–800 V (380–400 V line gives 750 V; 480–500 V gives 800 V).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput frequency:\u003c\/strong\u003e up to 599 Hz in U\/f mode, 250 Hz in VFCplus, 500 Hz in CFC, and 500 Hz in ELSM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e DC 24 V with -10%\/+20% tolerance; standby draw is 4.3 W for sizes 0020–0480.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy-saving standby:\u003c\/strong\u003e cuts standby consumption by up to \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e89%\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated motor power:\u003c\/strong\u003e 0.55 kW for a typical ASM, per the MOVIDRIVE modular motor assignment table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEncoder supply:\u003c\/strong\u003e peak 1000 mA at terminal X15.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e integrated STO per EN 61800-5-2 on the S00 variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Interference Resilience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0 to +45 °C with no derating needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -25 to +70 °C in non-condensing conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection rating:\u003c\/strong\u003e IP20, suited to clean control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e the manufacturer publishes no figure; keep the air non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterference resistance:\u003c\/strong\u003e the integrated STO function meets EN 61800-5-2 for safe torque isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and Expansion Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in system bus:\u003c\/strong\u003e backplane port X30 carries EtherCAT or SBusPLUS traffic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption card \/CES11A:\u003c\/strong\u003e adds multi-encoder support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption card \/CID21A:\u003c\/strong\u003e provides an encoder interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption card \/CIO21A:\u003c\/strong\u003e expands digital and analog I\/O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption card \/CS..A:\u003c\/strong\u003e adds a safety card for advanced safety tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption \/L:\u003c\/strong\u003e applies a conformal coated PCB for harsher surroundings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module inside an IP20 control cabinet and keep the DC link wiring short.\u003c\/li\u003e\n\u003cli\u003eFeed DC 24 V auxiliary power to terminal X5 before you start commissioning.\u003c\/li\u003e\n\u003cli\u003eConnect motor terminals U\/V\/W; sizes 1–2 use terminals, sizes 3–5 use X2 copper bars.\u003c\/li\u003e\n\u003cli\u003eWire the encoder to X15 and respect the 1000 mA peak supply limit.\u003c\/li\u003e\n\u003cli\u003eRoute the system bus through backplane port X30 for EtherCAT or SBusPLUS control.\u003c\/li\u003e\n\u003cli\u003eConfirm the STO circuit per EN 61800-5-2 before you enable motor operation.\u003c\/li\u003e\n\u003cli\u003eCheck that cabinet air stays between 0 and +45 °C during full-load runs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eMDA90A-0020-503-X-S00\u003c\/strong\u003e single-axis inverter module.\u003c\/li\u003e\n\u003cli\u003eTerminal covers and copper bars for the matching size.\u003c\/li\u003e\n\u003cli\u003ePrinted installation notes for the MOVIDRIVE® modular platform.\u003c\/li\u003e\n\u003cli\u003eProtective packaging rated for international courier transport.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe dispatch stock items within 5 days of order confirmation.\u003c\/li\u003e\n\u003cli\u003eWe ship worldwide through FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eYou receive a tracking number as soon as the courier scans the parcel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this module new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply the \u003cstrong\u003eMDA90A-0020-503-X-S00\u003c\/strong\u003e as a brand-new original unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you keep this item in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we hold this module in stock for immediate order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days using DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the module?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we accept returns within 30 days of delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What output current does this module deliver?\u003c\/strong\u003e\u003cbr\u003eA: It delivers 2 A rated current and handles 250% overload for 1 s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which DC link voltage does it accept?\u003c\/strong\u003e\u003cbr\u003eA: It works with a DC 750–800 V link from a matching supply module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it include a safety function?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the S00 variant includes integrated STO per EN 61800-5-2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The module runs from 0 to +45 °C without derating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SEW-EURODRIVE","offers":[{"title":"Default Title","offer_id":49269650161825,"sku":"MDA90A-0020-503-X-S00","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/MDA90A-0020-503-X-S00.jpg?v=1795677349","url":"https:\/\/www.autonexcontrol.com\/ru\/products\/mda90a-0020-503-x-s00-sew-eurodrive-single-axis-inverter-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}