{"product_id":"150-f135nbdd-allen-bradley-smc-flex-soft-starter","title":"150-F135NBDD Allen-Bradley Soft Starter SMC Flex","description":"\u003ch2\u003e\u003cstrong\u003eControlador de motor inteligente SMC Flex 150-F135NBDD - soft starter de 135 A da Allen-Bradley\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003ePrincipais especificações técnicas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarca:\u003c\/strong\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelo:\u003c\/strong\u003e \u003cstrong\u003e150-F135NBDD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSérie:\u003c\/strong\u003e SMC Flex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTipo de controlador:\u003c\/strong\u003e Soft starter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente nominal do controlador:\u003c\/strong\u003e 135 A, 25–100 Hp a 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensão de controle:\u003c\/strong\u003e 100…240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensão nominal de operação Ue:\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensão nominal de alimentação de controle:\u003c\/strong\u003e 100 V a 50 Hz e 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente de sobrecarga (conexão em linha):\u003c\/strong\u003e 34 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente de sobrecarga (conexão em delta):\u003c\/strong\u003e 59 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClasses de disparo:\u003c\/strong\u003e 10, 15, 20 e 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente nominal de disparo:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e117% da FLC do motor\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequência de operação:\u003c\/strong\u003e 50\/60 Hz para o circuito de potência\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente do motor conectado em linha:\u003c\/strong\u003e 34…135 A a 600\/Y\/690V AC, trifásico\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente do motor conectado em delta:\u003c\/strong\u003e 59…234 A a 500\/575V AC, trifásico\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotência máxima do motor conectado em linha:\u003c\/strong\u003e 90 kW a 500V AC a 50Hz, trifásico\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotência máxima do motor conectado em delta:\u003c\/strong\u003e 75 kW a 230V AC a 50Hz, trifásico\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensão de isolamento:\u003c\/strong\u003e Nominal de 500V conforme a IEC para o circuito de potência\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensão operacional nominal:\u003c\/strong\u003e 200…480V AC (-15%, +10%) conforme UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensão nominal de impulso:\u003c\/strong\u003e 6000V conforme a IEC para o circuito de potência\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuportabilidade dielétrica:\u003c\/strong\u003e 2500V conforme a IEC para o circuito de potência\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProteção DV\/DT:\u003c\/strong\u003e Rede de supressores RC para o circuito de potência\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensão inversa de pico repetitivo:\u003c\/strong\u003e 1400V conforme UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProteção contra transientes:\u003c\/strong\u003e Varistores de óxido metálico: 220 J (opcional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLista de dispositivos de proteção contra curto-circuito:\u003c\/strong\u003e Fusível padrão, disjuntor e fusível de alta capacidade com retardo das classes CC\/J\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente de falta disponível de alta capacidade, máx.:\u003c\/strong\u003e 70kA a 600V com fusível de 400 A com retardo da classe J ou classe L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente de falta disponível padrão, máx.:\u003c\/strong\u003e 70kA a 690V para a FLC máxima\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eRecursos de controle e monitoramento\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCom display:\u003c\/strong\u003e Sim\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTipo de tensão para acionamento:\u003c\/strong\u003e AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpções de controle:\u003c\/strong\u003e Controle de frenagem\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecurso padrão do controlador:\u003c\/strong\u003e Indicação de status para parado, partida, parada, em velocidade, alarme e falha\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecurso opcional do controlador:\u003c\/strong\u003e Controle inteligente de frenagem do motor SMB, com corrente de frenagem ajustável de 0…400% da FLC do motor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProteção integrada contra sobrecarga do motor:\u003c\/strong\u003e Sim\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTipo de desempenho do dispositivo de proteção contra curto-circuito (SCPD):\u003c\/strong\u003e Tipo 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNúmero máximo de sensores:\u003c\/strong\u003e 6 para entradas PTC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMódulo de controle da corrente de partida:\u003c\/strong\u003e 5A a 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensão nos terminais PTC (RPTC = aberto), máx.:\u003c\/strong\u003e 30V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMódulo de controle de potência transitória:\u003c\/strong\u003e 60 W a 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMódulo de controle de potência em regime permanente:\u003c\/strong\u003e 24 W a 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensão nos terminais PTC (RPTC = 4 kΩ), máx.:\u003c\/strong\u003e \u0026lt;7.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempo de resposta:\u003c\/strong\u003e 800 ms para entradas PTC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMódulo de controle do tempo de partida:\u003c\/strong\u003e 250 ms a 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMódulo de controle do tempo transitório:\u003c\/strong\u003e 500 ms a 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistência a frio da cadeia de sensores PTC, máx.:\u003c\/strong\u003e 1500 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEntrada do tacômetro:\u003c\/strong\u003e 0…5V DC a 4.5V DC = 100% da velocidade\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMódulo de controle da fonte de alimentação Allen Bradley, mín.:\u003c\/strong\u003e 1606-XLP50E a 24V DC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistência de disparo por curto-circuito:\u003c\/strong\u003e 25 Ω ± 10 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistência de resposta:\u003c\/strong\u003e 3400 Ω ± 150 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistência de reset:\u003c\/strong\u003e 1600 Ω ± 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensão máxima no estado desligado da entrada:\u003c\/strong\u003e 50V AC a 10V DC\/12V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensão mínima no estado ligado da entrada:\u003c\/strong\u003e 85V AC a 19.2V DC\/20.4V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente no estado desligado da entrada:\u003c\/strong\u003e \u0026lt;10 mA AC, \u0026lt;3 mA DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente no estado ligado da entrada:\u003c\/strong\u003e 20mA a 120V AC\/40mA a 240V AC, 7.6mA a 24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContatos auxiliares e dados do relé\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNúmero de contatos:\u003c\/strong\u003e 1 para contatos auxiliares\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTipo de corrente:\u003c\/strong\u003e AC para contatos auxiliares\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente térmica convencional (Ith):\u003c\/strong\u003e AC\/DC: 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTipo de circuito de controle:\u003c\/strong\u003e Relé eletromagnético\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTipo de contatos:\u003c\/strong\u003e NA\/NF programáveis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente operacional nominal:\u003c\/strong\u003e 3A a 120V AC, 1.5A a 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTipo de contato:\u003c\/strong\u003e Contatos auxiliares 19\/20 (Aux #1), 29\/30 (Aux #2), 31\/32 (Aux #3) e 33\/34 (Aux #4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFechamento:\u003c\/strong\u003e 3600VA para contatos auxiliares\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbertura:\u003c\/strong\u003e 360VA para contatos auxiliares\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDados térmicos, ambientais e mecânicos\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDissipação de calor em regime permanente com alimentação de controle e ventilador:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e104 W\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperatura de armazenamento e transporte:\u003c\/strong\u003e -20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUmidade:\u003c\/strong\u003e 5…95% (sem condensação)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperatura de operação:\u003c\/strong\u003e Aberto: -5 a 50 °C (23 a 122 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProteção contra choque elétrico:\u003c\/strong\u003e IP2X (com tampas dos terminais) conforme a IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNíveis de emissão EMC:\u003c\/strong\u003e Emissão irradiada: Classe A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNíveis de imunidade EMC:\u003c\/strong\u003e Transiente de surto conforme EN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrau de poluição:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeso:\u003c\/strong\u003e 15 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoque:\u003c\/strong\u003e Operacional: 5.5 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibração:\u003c\/strong\u003e Operacional: pico de 1.0 G, deslocamento de 0.15 mm (0.006 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLargura:\u003c\/strong\u003e 196.4 mm (7.74 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfundidade:\u003c\/strong\u003e 212.2 mm (8.35 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltura:\u003c\/strong\u003e 443.7 mm (17.47 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eVisão geral da construção e instalação\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstrução dos polos de potência:\u003c\/strong\u003e Projeto modular com tiristor em formato de pastilha tipo hockey puck e dissipador de calor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBypass interno:\u003c\/strong\u003e Sim\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunção:\u003c\/strong\u003e Uma direção\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdentificação dos terminais de potência:\u003c\/strong\u003e NEMA, CENELEC EN50 012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminais de controle:\u003c\/strong\u003e Conexão com garra de fixação, parafuso de fixação M3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminais de potência do lado da linha\/carga:\u003c\/strong\u003e Um furo de diâmetro M10 x 1.5 por polo de potência\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNúmero de polos:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGabinete:\u003c\/strong\u003e Tipo aberto\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstrução dos módulos de controle:\u003c\/strong\u003e Moldagens de termofixo e termoplástico\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstrução das peças metálicas:\u003c\/strong\u003e Latão niquelado, cobre ou aço pintado\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMódulo de controle do transformador:\u003c\/strong\u003e 75VA a 100…240V AC (-15%, +10%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotência nominal do ventilador do dissipador:\u003c\/strong\u003e 20VA a 110\/120V AC ou 220\/240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategoria de utilização:\u003c\/strong\u003e MG 1 conforme UL\/CSA\/NEMA para o circuito de potência\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente testada, estilo europeu, máx.:\u003c\/strong\u003e 6,9 gRB 73xxx400 6,6URD33xxx500 a 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente testada, estilo norte-americano, máx.:\u003c\/strong\u003e A070URD33xxx500 a 690V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConteúdo da embalagem\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Controlador de motor inteligente SMC Flex Allen-Bradley \u003cstrong\u003e150-F135NBDD\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e1 x Conjunto de tampas dos terminais para o circuito de potência\u003c\/li\u003e\n\u003cli\u003e1 x Documentação de instalação e uso\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvio e suporte\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnviamos para todo o mundo via FedEx, UPS e DHL.\u003c\/li\u003e\n\u003cli\u003eMantemos este modelo em estoque e o enviamos em até 5 dias.\u003c\/li\u003e\n\u003cli\u003eOferecemos devoluções em até 30 dias para pedidos elegíveis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eP: Qual é a corrente nominal do 150-F135NBDD?\u003c\/strong\u003e\u003cbr\u003eR: O \u003cstrong\u003e150-F135NBDD\u003c\/strong\u003e tem corrente nominal de 135 A e suporta 25–100 Hp a 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP: Este soft starter inclui proteção integrada contra sobrecarga do motor?\u003c\/strong\u003e\u003cbr\u003eR: Sim, ele inclui proteção integrada contra sobrecarga do motor e suporta as classes de disparo 10, 15, 20 e 30.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP: Qual tensão de controle este modelo aceita?\u003c\/strong\u003e\u003cbr\u003eR: Ele aceita tensão de controle de 100…240V AC e opera a 50\/60 Hz no circuito de potência.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP: Posso usar este controlador com motores conectados em delta?\u003c\/strong\u003e\u003cbr\u003eR: Sim, ele suporta corrente de motor conectado em delta de 59…234 A a 500\/575V AC, trifásico.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP: Qual é a faixa de temperatura de operação?\u003c\/strong\u003e\u003cbr\u003eR: A unidade de tipo aberto opera de -5 a 50 °C (23 a 122 °F), com umidade de 5…95% sem condensação.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP: Ele vem com display?\u003c\/strong\u003e\u003cbr\u003eR: Sim, este controlador SMC Flex inclui um display para indicação de status e monitoramento de falhas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP: Quais métodos de envio vocês utilizam?\u003c\/strong\u003e\u003cbr\u003eR: Enviamos via FedEx, UPS e DHL e geralmente despachamos em até 5 dias.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP: Qual é a política de devolução?\u003c\/strong\u003e\u003cbr\u003eR: Oferecemos devoluções em até 30 dias. O produto é novo e original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInformações de contato e consultas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eE-mail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eTelefone \/ WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eParceira NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47643994882209,"sku":"150-F135NBDD","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/150-F135NBDD.jpg?v=1789713389","url":"https:\/\/www.autonexcontrol.com\/pt\/products\/150-f135nbdd-allen-bradley-smc-flex-soft-starter","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}