{"product_id":"xnxxse1ss-honeywell-eto-transmitter-0-50-ppm-modbus-rtu","title":"XNXXSE1SS Honeywell ETO Transmitter 0-50 ppm Modbus RTU","description":"\u003ch2\u003e\u003cstrong\u003eXNXXSE1SS Honeywell XNX ETO Transmitter – 0-50 ppm Modbus RTU\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell Analytics \u003cstrong\u003eXNXXSE1SS\u003c\/strong\u003e – ETO transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas \u0026amp; Range:\u003c\/strong\u003e ETO (Ethylene Oxide) with selectable 20.0 to 50.0 ppm full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Range:\u003c\/strong\u003e 25.0 ppm with step increments of 5.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy \u0026amp; LOD:\u003c\/strong\u003e ±0.3 ppm accuracy; lower detectable limit = 1.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Times:\u003c\/strong\u003e T50 \u0026lt; 40 sec, T90 \u0026lt; 125 sec for reliable alarm activation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus Output:\u003c\/strong\u003e Isolated RS485 with baud rates from 1200 to 19.2K.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol \u0026amp; Nodes:\u003c\/strong\u003e Modbus RTU, supports up to 254 \u003cstrong\u003eXNX\u003c\/strong\u003e transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Operates from -20°C (-4°F) up to 55°C (131°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Default cal gas = 10.0 ppm (30-70% of selected span).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Connectivity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe Modbus output module installs inside the display housing at the factory.\u003c\/li\u003e\n\u003cli\u003eA qualified service engineer can also perform field installation as needed.\u003c\/li\u003e\n\u003cli\u003eConnections use RS485+, RS485-, and Drain terminals for reliable data transfer.\u003c\/li\u003e\n\u003cli\u003eThis isolated physical layer ensures robust communication in industrial settings.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eXNXXSE1SS\u003c\/strong\u003e does not support relays or Foundation Fieldbus options simultaneously.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEach package includes one \u003cstrong\u003eXNXXSE1SS\u003c\/strong\u003e ETO transmitter with Modbus module.\u003c\/li\u003e\n\u003cli\u003eWe also include a quick-start guide and terminal block connectors.\u003c\/li\u003e\n\u003cli\u003eWe ship all orders via FedEx, UPS, or DHL for fast global delivery.\u003c\/li\u003e\n\u003cli\u003eWe hold stock and dispatch within 5 working days after order confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the XNXXSE1SS brand new?\u003c\/strong\u003e\u003cbr\u003eYes, we supply only brand new, factory-sealed units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you keep this ETO transmitter in stock?\u003c\/strong\u003e\u003cbr\u003eYes, we maintain stock for immediate shipping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do you ship the XNX transmitter?\u003c\/strong\u003e\u003cbr\u003eWe use FedEx, UPS, or DHL with tracking numbers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the return policy for this item?\u003c\/strong\u003e\u003cbr\u003eWe accept returns within 30 days of delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this sensor with a 3-wire RS485 network?\u003c\/strong\u003e\u003cbr\u003eYes, it uses RS485+, RS485-, and Drain connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the default calibration gas value?\u003c\/strong\u003e\u003cbr\u003eThe factory default cal point is 10.0 ppm ETO.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I adjust the full scale range?\u003c\/strong\u003e\u003cbr\u003eYes, you can select any range from 20.0 to 50.0 ppm in 5.0 ppm steps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the lower detectable limit?\u003c\/strong\u003e\u003cbr\u003eThe LOD is 1.0 ppm for reliable low-level ETO detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e ， \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner NexAuto Technology Limited:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46900308836513,"sku":"XNXXSE1SS","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/XNXXSE1SS.jpg?v=1787132835","url":"https:\/\/www.autonexcontrol.com\/products\/xnxxse1ss-honeywell-eto-transmitter-0-50-ppm-modbus-rtu","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}