{"product_id":"xnxr1ss-honeywell-hydrogen-chloride-sensor-cell","title":"XNXR1SS Honeywell Hydrogen Chloride Sensor Cell","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXR1SS Hydrogen Chloride Sensor Cell\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell, \u003cstrong\u003eXNXR1SS\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Gas:\u003c\/strong\u003e Hydrogen Chloride (HCl)\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 – 10 ppm (extendable to 20.0 ppm)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e 1.0 ppm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e Less than 60 seconds\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +50°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 15% – 90% RH (non-condensing)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 3.0 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility \u0026amp; Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eXNXR1SS\u003c\/strong\u003e is a drop-in replacement for XNX series transmitters\u003c\/li\u003e\n\u003cli\u003eIt connects directly to the transmitter's sensor interface without additional adapters\u003c\/li\u003e\n\u003cli\u003eEach cell undergoes factory calibration for immediate out-of-box use\u003c\/li\u003e\n\u003cli\u003eInstallation takes less than 5 minutes with standard tools\u003c\/li\u003e\n\u003cli\u003eAlways power down the transmitter before replacing the sensor cell\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrochemical technology ensures excellent linearity across the full range\u003c\/li\u003e\n\u003cli\u003eBuilt-in temperature compensation maintains accuracy in varying conditions\u003c\/li\u003e\n\u003cli\u003eThe sensor resists common interfering gases like CO₂ and methane\u003c\/li\u003e\n\u003cli\u003eLong-term stability reduces drift and extends calibration intervals\u003c\/li\u003e\n\u003cli\u003eTypical sensor life exceeds 24 months in normal operating conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHoneywell XNXR1SS\u003c\/strong\u003e replaceable sensor cell (factory-sealed)\u003c\/li\u003e\n\u003cli\u003eProtective shipping cap and desiccant bag\u003c\/li\u003e\n\u003cli\u003eInstallation instruction sheet\u003c\/li\u003e\n\u003cli\u003eCalibration certificate with test data\u003c\/li\u003e\n\u003cli\u003eSensor identification label\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship all orders via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, or \u003cstrong\u003eDHL\u003c\/strong\u003e express services\u003c\/li\u003e\n\u003cli\u003eOrders dispatch within 5 business days from our warehouse\u003c\/li\u003e\n\u003cli\u003eAll \u003cstrong\u003eXNXR1SS\u003c\/strong\u003e units are brand new and in stock\u003c\/li\u003e\n\u003cli\u003eTracking numbers provided within 24 hours of shipment\u003c\/li\u003e\n\u003cli\u003eInternational shipping available with full customs documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the \u003cstrong\u003eXNXR1SS\u003c\/strong\u003e compatible with all XNX transmitters?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this sensor cell fits every XNX series universal transmitter with the appropriate gas personality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum detectable concentration for HCl?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eXNXR1SS\u003c\/strong\u003e can reliably detect down to 0.5 ppm with stable readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How often should I calibrate this sensor?\u003c\/strong\u003e\u003cbr\u003eA: Honeywell recommends calibration every 3–6 months depending on application and exposure levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does temperature affect the HCl reading?\u003c\/strong\u003e\u003cbr\u003eA: The sensor includes active temperature compensation to maintain accuracy from -20°C to +50°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy for this item?\u003c\/strong\u003e\u003cbr\u003eA: We accept returns within 30 days for unused, unopened sensor cells in original packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner NexAuto Technology Limited :\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46910870159521,"sku":"XNXR1SS","price":243.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/XNXR1SS.jpg?v=1787291927","url":"https:\/\/www.autonexcontrol.com\/products\/xnxr1ss-honeywell-hydrogen-chloride-sensor-cell","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}