{"product_id":"xnx-utse-nhnnn-honeywell-transmitter-stainless-steel-hart","title":"XNX-UTSE-NHNNN Honeywell Transmitter Stainless Steel HART","description":"\u003ch2\u003e\u003cstrong\u003eXNX-UTSE-NHNNN Universal Transmitter with Stainless Steel Enclosure\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Analytics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eXNX-UTSE-NHNNN\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Interface:\u003c\/strong\u003e Electrochemical cartridges (E) for toxic and oxygen sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Material:\u003c\/strong\u003e 316 stainless steel (S) for superior corrosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Entry:\u003c\/strong\u003e ¾\" NPT (T) for standard cable and conduit connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Interface:\u003c\/strong\u003e HART® (H) for on-site configuration and monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20mA analog with HART® digital communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C (-40°F to +149°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 0-99% RH (non-condensing).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 90-110 kPa for normal atmospheric conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +75°C (-40°F to +167°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Humidity:\u003c\/strong\u003e 0-99% RH non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e UL and CSA certified for safety and reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5 kg for robust and stable mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the \u003cstrong\u003eXNX-UTSE-NHNNN\u003c\/strong\u003e brand new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply only 100% genuine Honeywell transmitters with full factory warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What sensors does this model support?\u003c\/strong\u003e\u003cbr\u003eA: It supports Honeywell XNX toxic and oxygen electrochemical cartridges via the E interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this unit include a sensor?\u003c\/strong\u003e\u003cbr\u003eA: No, this version (NNN) comes without a sensor; you can order the appropriate cartridge separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have this transmitter in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we maintain stock of the \u003cstrong\u003eXNX-UTSE-NHNNN\u003c\/strong\u003e for quick dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does shipping take?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days; typical transit times are 2-5 business days with DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the unit if it does not fit my system?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we accept returns within 30 days of receiving the item.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the enclosure material?\u003c\/strong\u003e\u003cbr\u003eA: The housing is made of 316 stainless steel for excellent corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this support HART® communication?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes local HART® (H) for configuration and diagnostics via the 4-20mA loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What mounting options are available?\u003c\/strong\u003e\u003cbr\u003eA: You can surface mount via integral lugs, or use optional pipe (Ø100-150mm) or ceiling brackets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/861539249628?text=Inquiry%20about%20XNX-UTSE-NHNNN\"\u003e+86 153 9242 9628\u003c\/a\u003e .\u003cbr\u003e\u003cstrong\u003ePartner NexAuto Technology Limited:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46906126270625,"sku":"XNX-UTSE-NHNNN","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/XNX-UTSE-NHNNN.jpg?v=1787217417","url":"https:\/\/www.autonexcontrol.com\/products\/xnx-utse-nhnnn-honeywell-transmitter-stainless-steel-hart","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}