{"product_id":"xnx-utae-nnnnn-honeywell-gas-transmitter-electrochemical-interface","title":"XNX-UTAE-NNNNN Honeywell Gas Transmitter Electrochemical Interface","description":"\u003ch2\u003e\u003cstrong\u003eXNX-UTAE-NNNNN Universal Gas Transmitter by Honeywell\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNX-UTAE-NNNNN\u003c\/strong\u003e (XNX Universal Gas Transmitter).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval \u0026amp; Entry:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003eUL\/CSA certified\u003c\/span\u003e with ¾\" NPT cable entry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial \u0026amp; Personality:\u003c\/strong\u003e Aluminium housing; Electrochemical Cartridge interface with IS barrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Input:\u003c\/strong\u003e Designed for \u003cspan style=\"color: #cc0000;\"\u003eXNX toxic and oxygen electrochemical sensors\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 4-20mA with HART® (no Modbus, no local HART installed).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.8 Kg (compact and lightweight).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Interface:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003eElectrochemical Cartridge\u003c\/span\u003e with integrated IS barrier and adaptor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Sensors:\u003c\/strong\u003e XNX toxic gas sensors and oxygen sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20 mA with HART® protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Aluminium – lightweight with good thermal conductivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Entry:\u003c\/strong\u003e ¾\" NPT thread.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C (-40°F to +149°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 0-99% RH (non-condensing).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 90-110 kPa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions:\u003c\/strong\u003e -40°C to 75°C (-40°F to 167°F), 0-99% non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 16 cm x 19.7 cm x 11.4 cm (6.1\" x 7.8\" x 4.5\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What sensors work with the \u003cstrong\u003eXNX-UTAE-NNNNN\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eA: It supports XNX toxic gas sensors and oxygen sensors that use the electrochemical cartridge format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the purpose of the IS barrier?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cspan style=\"color: #cc0000;\"\u003eintrinsically safe barrier\u003c\/span\u003e limits energy to the sensor for safe operation in hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this model include a sensor?\u003c\/strong\u003e\u003cbr\u003eA: No, the sensor (NNN) is not included. You must order the compatible XNX electrochemical sensor separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What approvals does the \u003cstrong\u003eXNX-UTAE-NNNNN\u003c\/strong\u003e carry?\u003c\/strong\u003e\u003cbr\u003eA: It carries \u003cspan style=\"color: #cc0000;\"\u003eUL and CSA\u003c\/span\u003e certifications for North American markets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this transmitter with a 4-20mA sensor from another brand?\u003c\/strong\u003e\u003cbr\u003eA: This version is specifically designed for XNX electrochemical cartridges, not for generic 4-20mA inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What power supply does it require?\u003c\/strong\u003e\u003cbr\u003eA: It operates on 12-32 V DC (nominal 24 V DC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the \u003cstrong\u003eXNX-UTAE-NNNNN\u003c\/strong\u003e suitable for SIL applications?\u003c\/strong\u003e\u003cbr\u003eA: Please refer to the Honeywell safety manual for SIL certification details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003cbr\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46906062078113,"sku":"XNX-UTAE-NNNNN","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/XNX-UTAE-NNNNN.jpg?v=1787215895","url":"https:\/\/www.autonexcontrol.com\/products\/xnx-utae-nnnnn-honeywell-gas-transmitter-electrochemical-interface","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}