{"product_id":"v18347-2041150001-abb-tzidc-120-positioner","title":"V18347-2041150001 ABB TZIDC-120 Positioner","description":"\u003ch2\u003e\u003cstrong\u003eABB V18347-2041150001 TZIDC-120 Electro-Pneumatic Positioner for FOUNDATION Fieldbus\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eV18347-2041150001\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e TZIDC-120\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Electro-pneumatic positioner, intelligent, configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e FOUNDATION Fieldbus input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion protection:\u003c\/strong\u003e ATEX EEx ia IIC T6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput \/ safe position:\u003c\/strong\u003e Single acting, fail safe on electrical power failure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase:\u003c\/strong\u003e Varnished aluminium, mechanical position indicator, IP 65 \/ NEMA 4X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Linear actuator per DIN\/IEC 534\/NAMUR, or rotary actuator per VDI\/VDE 3845\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Cable thread M20 x 1.5, air pipe thread 1\/4-18 NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption module for shutdown:\u003c\/strong\u003e Without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical kit for digital position feedback:\u003c\/strong\u003e Without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e Standard varnish and coding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Capabilities and Operating Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature:\u003c\/strong\u003e -40 °C to +85 °C for operation, storage and transport\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature with proximity switches SJ2-S1N (NO):\u003c\/strong\u003e -25 °C to +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity, operational:\u003c\/strong\u003e 95 % annual average with closed housing and air supply on, condensation permissible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity, transport and storage:\u003c\/strong\u003e 75 % annual average, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase material and protection:\u003c\/strong\u003e Aluminium with IP 65 \/ NEMA 4X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface and colour:\u003c\/strong\u003e Electrostatic dipping varnish with epoxy resin, stove-hardened, black RAL 9005 matt case, Pantone 420 cap\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.7 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical and Pneumatic Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals:\u003c\/strong\u003e max. 1.0 mm² for options, max. 2.5 mm² for analog signal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotice:\u003c\/strong\u003e Do not expose the terminals to strain\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entry:\u003c\/strong\u003e 2 threads 1\/2-14 NPT or M20 x 1.5, 1 with cable gland and 1 with pipe plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePneumatic connections:\u003c\/strong\u003e Threads G 1\/4 or 1\/4-18 NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e \u003cspan style=\"color: #0b6e4f;\"\u003eThe fail-safe action helps protect the valve position when electrical power fails.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eV18347-2041150001\u003c\/strong\u003e to a linear actuator per DIN\/IEC 534\/NAMUR or to a rotary actuator per VDI\/VDE 3845.\u003c\/li\u003e\n\u003cli\u003eUse the mechanical position indicator to confirm the actuator stroke or angle during setup.\u003c\/li\u003e\n\u003cli\u003eConnect the air pipe with 1\/4-18 NPT thread and keep the supply air clean and dry.\u003c\/li\u003e\n\u003cli\u003eWire the FOUNDATION Fieldbus cable through the M20 x 1.5 entry and tighten the cable gland.\u003c\/li\u003e\n\u003cli\u003eKeep screw terminals free from strain and respect the maximum wire sizes shown above.\u003c\/li\u003e\n\u003cli\u003eCheck the IP 65 \/ NEMA 4X seal after mounting in outdoor or washdown areas.\u003c\/li\u003e\n\u003cli\u003eVerify the safe position after electrical power failure before placing the loop into service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement and Performance Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe TZIDC-120 series provides intelligent, configurable valve position control.\u003c\/li\u003e\n\u003cli\u003eThe positioner reads the valve position and compares it with the Fieldbus setpoint.\u003c\/li\u003e\n\u003cli\u003eThe unit then adjusts the pneumatic output to reduce position error.\u003c\/li\u003e\n\u003cli\u003eLinear and rotary motion both benefit from the mechanical position indicator.\u003c\/li\u003e\n\u003cli\u003eThe robust aluminium case resists vibration, dust and moisture in process plants.\u003c\/li\u003e\n\u003cli\u003eThe ATEX EEx ia IIC T6 rating supports use in hazardous gas atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB \u003cstrong\u003eV18347-2041150001\u003c\/strong\u003e TZIDC-120 positioner\u003c\/li\u003e\n\u003cli\u003e1 x cable gland\u003c\/li\u003e\n\u003cli\u003e1 x pipe plug\u003c\/li\u003e\n\u003cli\u003e1 x mechanical position indicator, pre-installed\u003c\/li\u003e\n\u003cli\u003e1 x mounting accessory set for NAMUR or VDI\/VDE 3845 mounting\u003c\/li\u003e\n\u003cli\u003e1 x quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship with FedEx, UPS and DHL to most international destinations.\u003c\/li\u003e\n\u003cli\u003eWe keep this item in stock and dispatch it within 5 days.\u003c\/li\u003e\n\u003cli\u003eWe offer 30-day returns for eligible orders.\u003c\/li\u003e\n\u003cli\u003eAll units are brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What communication protocol does the \u003cstrong\u003eV18347-2041150001\u003c\/strong\u003e use?\u003c\/strong\u003e\u003cbr\u003eA: It uses FOUNDATION Fieldbus for digital communication with the control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the ambient temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The standard range is -40 °C to +85 °C, and -25 °C to +85 °C with certain proximity switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the explosion protection rating?\u003c\/strong\u003e\u003cbr\u003eA: The unit carries ATEX EEx ia IIC T6 certification for hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the safe position on power failure?\u003c\/strong\u003e\u003cbr\u003eA: It is single acting and fail safe, so the valve moves to its safe position when electrical power fails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What are the pneumatic connection threads?\u003c\/strong\u003e\u003cbr\u003eA: The air pipe connection uses 1\/4-18 NPT thread, with G 1\/4 also listed for the series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How much does the positioner weigh?\u003c\/strong\u003e\u003cbr\u003eA: The unit weighs approximately 1.7 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have this item in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep it in stock and ship within 5 days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47169888125089,"sku":"V18347-2041150001","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/V18347-2041150001.jpg?v=1789022415","url":"https:\/\/www.autonexcontrol.com\/products\/v18347-2041150001-abb-tzidc-120-positioner","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}