{"product_id":"v18345-1010551001-abb-tzidc-120-valve-positioner","title":"V18345-1010551001 ABB TZIDC-120 Valve Positioner","description":"\u003ch2\u003e\u003cstrong\u003eABB V18345-1010551001 TZIDC-120 Intelligent Valve Positioner\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eV18345-1010551001\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e TZIDC-120 Intelligent Positioner, series V18345\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput signal:\u003c\/strong\u003e Two-wire technology, nominal range 4…20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit range:\u003c\/strong\u003e Configurable between \u003cspan style=\"color: #c0392b;\"\u003e20% and 100%\u003c\/span\u003e of the nominal range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. input:\u003c\/strong\u003e 25 mA \/ 30 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMin. input:\u003c\/strong\u003e 3.4 mA without analog position feedback; 3.5 mA with analog position feedback\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart value:\u003c\/strong\u003e From 3.8 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad voltage at 20 mA:\u003c\/strong\u003e 8.7 V DC without explosion protection; 9.7 V DC for intrinsically safe device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance at 20 mA:\u003c\/strong\u003e 435 ohms without explosion protection; 485 ohms for intrinsically safe device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital input:\u003c\/strong\u003e Control voltage 24 V DC (12…30 V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogical “0”:\u003c\/strong\u003e 0…10 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogical “1”:\u003c\/strong\u003e 12…30 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital input current:\u003c\/strong\u003e Max. 4 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital output (DIN 19234\/NAMUR):\u003c\/strong\u003e Supply voltage 5…11 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogical “0” current:\u003c\/strong\u003e \u0026lt; 1.0 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogical “1” current:\u003c\/strong\u003e \u0026gt; 2.0 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEffective direction:\u003c\/strong\u003e Normally logical “0” or logical “1”, configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput range:\u003c\/strong\u003e 0…6 bar (0…90 psi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir capacity at 1.4 bar (20 psi):\u003c\/strong\u003e 5.0 kg\/h = 3.9 Nm3\/h = 2.3 scfm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir capacity at 6 bar (90 psi):\u003c\/strong\u003e 13 kg\/h = 10 Nm3\/h = 6.0 scfm (booster on request)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput function:\u003c\/strong\u003e For single or double acting actuators; air vents from actuator or actuator blocks on electrical power failure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShut-off values:\u003c\/strong\u003e End position 0% = 0…45%; end position 100% = 55…100%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e Aluminum, varnished, IP 65 \/ NEMA 4X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Cable thread M20 x 1.5; air pipe thread 1\/4-18 NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption modules:\u003c\/strong\u003e Plug-in analog position feedback (signal range 4…20 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional mechanical kit for digital position feedback:\u003c\/strong\u003e Without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion protection:\u003c\/strong\u003e Without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign (varnish \/ coding):\u003c\/strong\u003e Standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat input signal does the V18345-1010551001 accept?\u003c\/strong\u003e It accepts a 4…20 mA two-wire signal with a minimum start value of 3.8 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the output pressure range?\u003c\/strong\u003e The output range is 0…6 bar (0…90 psi) with air capacity up to 13 kg\/h at 6 bar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this model support fail-safe operation?\u003c\/strong\u003e Yes, it provides double-acting fail-freeze action on electrical power failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the pneumatic and cable connections?\u003c\/strong\u003e Cable thread is M20 x 1.5 and air pipe thread is 1\/4-18 NPT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I configure a split range?\u003c\/strong\u003e Yes, split range configuration works between 20% and 100% of the nominal range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the load voltage at 20 mA?\u003c\/strong\u003e It is 8.7 V DC without explosion protection and 9.7 V DC for intrinsically safe devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47169844641953,"sku":"V18345-1010551001","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/V18345-1010221001-6_99b2339e-2c42-4ce0-b3d1-a619ee06b8c1.jpg?v=1788946295","url":"https:\/\/www.autonexcontrol.com\/products\/v18345-1010551001-abb-tzidc-120-valve-positioner","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}