{"product_id":"v18345-1010120001-abb-tzidc-positioner-4-20-ma","title":"V18345-1010120001 ABB TZIDC Positioner 4-20 mA","description":"\u003ch2\u003e\u003cstrong\u003eABB V18345-1010120001 TZIDC Electro-Pneumatic Positioner\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eV18345-1010120001\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e TZIDC Electro-Pneumatic Positioner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e V18345 TZIDC intelligent, configurable with indicator and operator panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase \/ mounting:\u003c\/strong\u003e Aluminium case, varnished, IP 65 (NEMA 4X), for linear actuators to DIN\/IEC 534 \/ NAMUR or rotary actuators to VDI\/VDE 3845, also ready for integral mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput \/ communication port:\u003c\/strong\u003e 4...20 mA, two-wire, with connector plug for LKS adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion protection:\u003c\/strong\u003e Without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput \/ safe position:\u003c\/strong\u003e Single acting, fail safe in case of electrical power failure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Cable thread 1\/2-14 NPT; air pipe thread 1\/4-18 NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption modules for analog or digital position feedback:\u003c\/strong\u003e Without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional mechanical kit for digital position feedback:\u003c\/strong\u003e Without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e Standard varnish \/ coding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput signal:\u003c\/strong\u003e Two-wire technology, nominal range 4...20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital input:\u003c\/strong\u003e Control voltage 0...5 V DC for logical state \"0\"; 11...30 V DC for logical state \"1\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital output:\u003c\/strong\u003e Control circuit to DIN 19234\/NAMUR; supply voltage 5...11 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply pressure:\u003c\/strong\u003e 1.4...6 bar (20...90 psi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir consumption:\u003c\/strong\u003e \u0026lt; 0.03 kg\/h \/ 0.015 scfm, independent of supply pressure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material \/ protection:\u003c\/strong\u003e Aluminium, IP 65 \/ NEMA 4X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface \/ color:\u003c\/strong\u003e Electrostatic dipping varnish with epoxy resin, stove-hardened; case varnished black RAL 9005 matte; housing cover Pantone 420\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePneumatic connections:\u003c\/strong\u003e Threads G 1\/4 or 1\/4-18 NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.7 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature for operation, storage and transport:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-40...85 °C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature with proximity switches SJ2-S1N (NO):\u003c\/strong\u003e -25...85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity operational:\u003c\/strong\u003e 95 % annual average with closed housing and air supply switched on; condensation permissible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity transport and storage:\u003c\/strong\u003e 75 % annual average, noncondensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material \/ protection:\u003c\/strong\u003e Aluminium, IP 65 \/ NEMA 4X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface \/ color:\u003c\/strong\u003e Electrostatic dipping varnish with epoxy resin, stove-hardened; case varnished black RAL 9005 matte; housing cover Pantone 420\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical and Pneumatic Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals:\u003c\/strong\u003e Max. 1.0 mm² for options; max. 2.5 mm² for analog signal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal note:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eDo not expose the terminals to strain.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entry:\u003c\/strong\u003e 2 tap holes 1\/2-14 NPT or M20 x 1.5 (1 x with cable gland and 1 x with pipe plug)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePneumatic connections:\u003c\/strong\u003e Threads G 1\/4 or 1\/4-18 NPT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal, Action and Characteristic Curve\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal:\u003c\/strong\u003e Min. 4 mA, max. 20 mA (0...100 %), freely selectable for split-range operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum range:\u003c\/strong\u003e 20 % (3.2 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended range:\u003c\/strong\u003e \u0026gt; 50 % (8.0 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAction increasing:\u003c\/strong\u003e Signal 4...20 mA = position 0...100 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAction increasing:\u003c\/strong\u003e Signal 20...4 mA = position 0...100 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharacteristic curve:\u003c\/strong\u003e Linear, equal percentage 1:25 or 1:50 or 25:1 or 50:1, or freely configurable with 20 reference points\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTravel Limit, Shut-Off and Travel Time Prolongation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTravel limit:\u003c\/strong\u003e The positioning travel, stroke or angle of rotation, can reduce as required within 0...100 %, provided that a minimum value of 20 % remains\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShut-off function:\u003c\/strong\u003e This parameter can set separately for each end position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShut-off action:\u003c\/strong\u003e When the configured limit value exceeds, the shut-off function causes immediate travel of the actuator until reaching the set end position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShut-off value \"0\":\u003c\/strong\u003e The position is further controlled, even in the respective end position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTravel time prolongation:\u003c\/strong\u003e This function can increase the max. travel time for full travel; this time parameter can set separately for each direction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the positioner to linear actuators according to DIN\/IEC 534 \/ NAMUR or to rotary actuators according to VDI\/VDE 3845\u003c\/li\u003e\n\u003cli\u003eUse the integral mounting option when the actuator provides a suitable interface\u003c\/li\u003e\n\u003cli\u003eConnect the 4...20 mA two-wire input with the connector plug for the LKS adapter\u003c\/li\u003e\n\u003cli\u003eUse cable thread 1\/2-14 NPT and air pipe thread 1\/4-18 NPT for the connection ports\u003c\/li\u003e\n\u003cli\u003eKeep supply pressure within 1.4...6 bar (20...90 psi)\u003c\/li\u003e\n\u003cli\u003eDo not expose the screw terminals to strain\u003c\/li\u003e\n\u003cli\u003eObserve ambient temperature limits of -40...85 °C for standard operation\u003c\/li\u003e\n\u003cli\u003eUse proximity switches SJ2-S1N (NO) only within -25...85 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB \u003cstrong\u003eV18345-1010120001\u003c\/strong\u003e TZIDC Electro-Pneumatic Positioner\u003c\/li\u003e\n\u003cli\u003e1 x Cable gland\u003c\/li\u003e\n\u003cli\u003e1 x Pipe plug\u003c\/li\u003e\n\u003cli\u003e1 x Mounting kit according to the selected actuator interface\u003c\/li\u003e\n\u003cli\u003e1 x Quick reference for wiring, air connection and setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock:\u003c\/strong\u003e We keep this item in stock for fast order processing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e We ship within 5 days after order confirmation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCourier:\u003c\/strong\u003e FedEx, UPS, DHL and other common express services\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReturn policy:\u003c\/strong\u003e We support return within 30 days\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new and original\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the input signal range of the ABB V18345-1010120001?\u003c\/strong\u003e The unit uses a 4...20 mA two-wire input with a nominal range of 4...20 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat supply pressure does this positioner require?\u003c\/strong\u003e It operates with 1.4...6 bar (20...90 psi) supply pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the ambient temperature range?\u003c\/strong\u003e Standard operation, storage and transport support -40...85 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this model include explosion protection?\u003c\/strong\u003e No, this version comes without explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the output action in case of power failure?\u003c\/strong\u003e It provides single-acting fail-safe output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat pneumatic connection threads does it use?\u003c\/strong\u003e It uses threads G 1\/4 or 1\/4-18 NPT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use split-range operation?\u003c\/strong\u003e Yes, the signal range is freely selectable for split-range operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the minimum travel limit?\u003c\/strong\u003e The travel limit can reduce within 0...100 %, but it must keep a minimum value of 20 %.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow much does the positioner weigh?\u003c\/strong\u003e The weight is 1.7 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the air consumption?\u003c\/strong\u003e Air consumption is below 0.03 kg\/h \/ 0.015 scfm, independent of supply pressure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e for quick support.\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47170285076641,"sku":"V18345-1010120001","price":208.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/V18345-1010120001.jpg?v=1789026424","url":"https:\/\/www.autonexcontrol.com\/products\/v18345-1010120001-abb-tzidc-positioner-4-20-ma","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}