{"product_id":"v18345-1004210001-abb-electro-pneumatic-positioner","title":"V18345-1004210001 ABB Electro-Pneumatic Positioner","description":"\u003ch2\u003e\u003cstrong\u003eABB V18345-1004210001 Electro-Pneumatic Positioner with ATEX Zone 2 Protection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eV18345-1004210001\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Electro-Pneumatic Positioner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e Two-wire technology, nominal range 4...20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit Range:\u003c\/strong\u003e Configurable between 20% and 100% of nominal range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input:\u003c\/strong\u003e 25 mA \/ 30 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Input:\u003c\/strong\u003e 3.4 mA without analog position feedback, 3.5 mA with analog position feedback\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart Point:\u003c\/strong\u003e 3.8 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Voltage at 20 mA:\u003c\/strong\u003e 8.7 V DC without explosion protection, 9.7 V DC for intrinsically safe device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance at 20 mA:\u003c\/strong\u003e 435 ohms without explosion protection, 485 ohms for intrinsically safe device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Input:\u003c\/strong\u003e Control voltage 24 V DC (12...30 V DC), logical \"0\" at 0...10 V DC, logical \"1\" at 12...30 V DC, max current 4 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Output:\u003c\/strong\u003e Control circuit to DIN 19234\/NAMUR, supply voltage 5...11 V DC, current \u0026lt; 1.0 mA for logical \"0\", current \u0026gt; 2.0 mA for logical \"1\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Range:\u003c\/strong\u003e 0...6 bar (0...90 psi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Capacity at 1.4 bar:\u003c\/strong\u003e 5.0 kg\/h = 3.9 Nm3\/h = 2.3 scfm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Capacity at 6 bar:\u003c\/strong\u003e 13 kg\/h = 10 Nm3\/h = 6.0 scfm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Function:\u003c\/strong\u003e Single or double acting actuators, fail freeze on electrical power failure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShut-off Values:\u003c\/strong\u003e End position 0% = 0...45%, end position 100% = 55...100%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAngle of Rotation:\u003c\/strong\u003e 25...120° for rotary actuators, optional 270°; 25...60° for linear actuators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTravel Limit:\u003c\/strong\u003e Freely configurable within 0...100% of total travel, minimum range \u0026gt; 20%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTravel Time Prolongation:\u003c\/strong\u003e 0...200 seconds, separately for each direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositioning Time Limit:\u003c\/strong\u003e 0...200 seconds monitoring parameter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Pressure:\u003c\/strong\u003e 1.4...6 bar (20...90 psi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Consumption:\u003c\/strong\u003e \u0026lt; 0.03 kg\/h \/ 0.015 scfm, independent of supply pressure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharacteristic Curve:\u003c\/strong\u003e Linear, equal percentage 1:25 or 1:50 or 25:1 or 50:1, freely configurable with 20 reference points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharacteristic Deviation:\u003c\/strong\u003e ≤ 0.5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTolerance Band:\u003c\/strong\u003e 0.3...10%, adjustable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDead Band:\u003c\/strong\u003e 0.1...10%, adjustable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e \u0026gt; 4000 steps (A\/D conversion)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Rate:\u003c\/strong\u003e 20 msec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Temperature Influence:\u003c\/strong\u003e ≤ 0.5% for every 10 °C change\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Influence:\u003c\/strong\u003e ≤ ± 1% up to 10 g and 80 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeismic Requirements:\u003c\/strong\u003e Meets DIN\/IEC 68-3-3 Class III for strong and strongest earthquakes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation Influence:\u003c\/strong\u003e No effect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e -40...+85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e HART Protocol 5.1, local connector for LKS adapter, HART communication via 20 mA signal line with FSK modem\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e Aluminium, varnished, IP 65 (NEMA 4X)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Linear actuators per DIN\/IEC 534 \/ NAMUR, rotary actuators per VDI\/VDE 3845, integral mounting ready\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Cable thread 1\/2-14 NPT, air pipe thread 1\/4-18 NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption Module:\u003c\/strong\u003e Without analog or digital position feedback\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Kit:\u003c\/strong\u003e Without digital position feedback\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e Standard varnish and coding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.7 Kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion Protection:\u003c\/strong\u003e ATEX EEx n A II T6, Zone 2, TÜV 02 ATEX 1943 X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e ATEX, FM, CSA, IECEx, suitable for SIL2 safety loops\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirectives:\u003c\/strong\u003e EMC Directive 89\/336\/EEC, CE conformity marking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the input signal range of the V18345-1004210001?\u003c\/strong\u003e\u003cbr\u003eA: It uses a two-wire 4...20 mA nominal range with split range configuration from 20% to 100%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this positioner support HART communication?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes an FSK module for HART communication and supports HART Protocol 5.1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What explosion protection does this model carry?\u003c\/strong\u003e\u003cbr\u003eA: It carries ATEX EEx n A II T6 certification for Zone 2 hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the safe position on electrical power failure?\u003c\/strong\u003e\u003cbr\u003eA: This model provides fail freeze, which blocks the actuator in its last position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The positioner works from -40...+85 °C for operation, storage, and transport.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What air supply pressure does it require?\u003c\/strong\u003e\u003cbr\u003eA: It needs 1.4...6 bar (20...90 psi) and must not exceed the actuator maximum pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the resolution of the A\/D conversion?\u003c\/strong\u003e\u003cbr\u003eA: The resolution exceeds 4000 steps with a 20 msec sample rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this unit suitable for SIL2 safety loops?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it meets SIL2 requirements and holds ATEX, FM, CSA, and IECEx approvals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the air consumption?\u003c\/strong\u003e\u003cbr\u003eA: Air consumption stays below 0.03 kg\/h or 0.015 scfm, independent of supply pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the weight of the positioner?\u003c\/strong\u003e\u003cbr\u003eA: The unit weighs 1.7 Kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone \/ WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47170357723297,"sku":"V18345-1004210001","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/V18345-1004210001.jpg?v=1789027160","url":"https:\/\/www.autonexcontrol.com\/products\/v18345-1004210001-abb-electro-pneumatic-positioner","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}