{"product_id":"tu830v1-abb-extended-termination-unit-16-channels","title":"TU830V1 ABB Extended Termination Unit 16 Channels","description":"\u003ch2\u003e\u003cstrong\u003eABB TU830V1 Extended Termination Unit – 16-Channel Fused I\/O Interface\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Extended Module Termination Unit (MTU).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB – a global leader in industrial automation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ Type Designation:\u003c\/strong\u003e \u003cstrong style=\"color: #cc0000;\"\u003eTU830V1\u003c\/strong\u003e (Order code: 3BSE013234R1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 I\/O channels, each rated at 50V and 2A maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFused Groups:\u003c\/strong\u003e Two isolated process voltage groups, each with a 6.3A fuse.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 50 V per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current per Channel:\u003c\/strong\u003e 2 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Connection Current:\u003c\/strong\u003e Up to 5 A per group.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Sizes (Solid):\u003c\/strong\u003e 0.2 – 4 mm².\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Sizes (Stranded):\u003c\/strong\u003e 0.2 – 2.5 mm² (24–12 AWG).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Torque:\u003c\/strong\u003e 0.5 – 0.6 Nm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStripping Length:\u003c\/strong\u003e 7 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Test Voltage:\u003c\/strong\u003e 500 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Horizontal or vertical (max 55 °C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20 (IEC 60529).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental \u0026amp; Certification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to +55 °C (+32 to +131 °F) – approvals from +5 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to +70 °C (-40 to +158 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5 to 95 % (non-condensing).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Protection:\u003c\/strong\u003e ISA-S71.04 G3 compliant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Yes – plus UL, ATEX Zone 2, and hazardous location approvals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Certificates:\u003c\/strong\u003e ABS, BV, DNV-GL, LR.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e EN 61000-6-4 and EN 61000-6-2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the TU830V1 a passive or active module?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eTU830V1\u003c\/strong\u003e is a passive termination unit – it does not require external power and simply routes signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the purpose of the two fuses?\u003c\/strong\u003e\u003cbr\u003eA: Each isolated process group has a 6.3A fuse to protect against overcurrent – replace with the same rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which I\/O modules are compatible with this MTU?\u003c\/strong\u003e\u003cbr\u003eA: It works with many ABB S800 modules including AI, AO, DI, DO, and DP series – see the list above.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between TU830V1 and TU814V1?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eTU830V1\u003c\/strong\u003e is the \"Extended\" version with fused groups and terminal block connections, while TU814V1 is \"Compact\" with crimp connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I mount this unit vertically?\u003c\/strong\u003e\u003cbr\u003eA: Yes – the maximum ambient temperature is 55 °C for both horizontal and vertical mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have this item in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep \u003cspan style=\"color: #cc0000;\"\u003estock available\u003c\/span\u003e for the \u003cstrong\u003eABB TU830V1\u003c\/strong\u003e (3BSE013234R1).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\" style=\"color: #cc0000;\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\" style=\"color: #cc0000;\"\u003e+86 153 9242 9628\u003c\/a\u003e (WhatsApp).\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\" style=\"color: #cc0000;\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46794689511585,"sku":"TU830V1","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/TU830V1-1.jpg?v=1785478200","url":"https:\/\/www.autonexcontrol.com\/products\/tu830v1-abb-extended-termination-unit-16-channels","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}