{"product_id":"tm5sai2ph-schneider-analog-input-module-2-channel-pt100","title":"TM5SAI2PH Schneider Analog Input Module 2-Channel PT100","description":"\u003ch2\u003e\u003cstrong\u003eTM5SAI2PH Analog Input Module for Precise Temperature Measurement\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #0073aa;\"\u003e\u003cstrong\u003eSchneider Electric\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eTM5SAI2PH\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Analog input module for temperature probes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput channels:\u003c\/strong\u003e 2 channels for Pt 100 \/ Pt 1000 probes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement range:\u003c\/strong\u003e -200 to 850 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e \u003cspan style=\"color: #d63638;\"\u003e\u003cstrong\u003e16 bits\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement resolution:\u003c\/strong\u003e 0.1 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement error:\u003c\/strong\u003e Less than 0.037 % of full scale at 25 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature coefficient:\u003c\/strong\u003e 0.004 %FS\/°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-linearity:\u003c\/strong\u003e 0.00015 %FS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e \u003cspan style=\"color: #0073aa;\"\u003e\u003cstrong\u003e500 Vrms AC\u003c\/strong\u003e\u003c\/span\u003e between channel and bus; no insulation between channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon mode rejection:\u003c\/strong\u003e Greater than 95 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 24 V DC (-15 % to +20 %)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 2 mA at 5 V DC bus; 46 mA at 24 V DC input\/output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum power dissipation:\u003c\/strong\u003e 1.11 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal indicators:\u003c\/strong\u003e Green and red LEDs for power; green LEDs for input status\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable type:\u003c\/strong\u003e Shielded cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet weight:\u003c\/strong\u003e 0.025 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Tolerance and EMC Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e \u003cspan style=\"color: #0073aa;\"\u003e\u003cstrong\u003e0 to 55 °C\u003c\/strong\u003e\u003c\/span\u003e without derating (vertical mounting); 0 to 60 °C with derating; 0 to 50 °C (vertical mounting)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -25 to 70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5 to 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection degree:\u003c\/strong\u003e IP20 according to IEC 61131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2 according to IEC 60664\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 0 to 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage altitude:\u003c\/strong\u003e 0 to 3000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e 1 gn at 8.4 to 150 Hz; 3.5 mm at 5 to 8.4 Hz on DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock resistance:\u003c\/strong\u003e 15 gn for 11 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic discharge:\u003c\/strong\u003e \u003cspan style=\"color: #d63638;\"\u003e\u003cstrong\u003e4 kV contact \/ 8 kV air\u003c\/strong\u003e\u003c\/span\u003e per IEC 61000-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic field:\u003c\/strong\u003e 10 V\/m at 80 to 2000 MHz; 1 V\/m at 2 to 2.7 GHz per IEC 61000-4-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient immunity:\u003c\/strong\u003e 1 kV for I\/O and shielded cables; 2 kV for power lines per IEC 61000-4-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge tolerance:\u003c\/strong\u003e 0.5 kV differential mode; 1 kV common mode per IEC 61000-4-5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConducted disturbances:\u003c\/strong\u003e EN\/IEC 61000-4-6; CISPR 11 for radiated and conducted emissions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eTM5SAI2PH\u003c\/strong\u003e on a DIN rail inside a control cabinet with IP20 protection.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for all temperature probe connections to maintain EMC performance.\u003c\/li\u003e\n\u003cli\u003eKeep channel wiring away from power lines to reduce common mode noise.\u003c\/li\u003e\n\u003cli\u003eRespect the \u003cspan style=\"color: #0073aa;\"\u003e\u003cstrong\u003e0 to 55 °C\u003c\/strong\u003e\u003c\/span\u003e operating range for vertical mounting without derating.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 V DC supply stays within -15 % to +20 % of nominal voltage.\u003c\/li\u003e\n\u003cli\u003eConnect Pt 100 or Pt 1000 probes according to the wiring diagram for 2-channel input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eTM5SAI2PH\u003c\/strong\u003e analog input module\u003c\/li\u003e\n\u003cli\u003e1 x protective packaging (40 g total package weight)\u003c\/li\u003e\n\u003cli\u003ePackage dimensions: 2.0 cm height x 6.0 cm width x 10.5 cm length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship worldwide via \u003cspan style=\"color: #0073aa;\"\u003e\u003cstrong\u003eFedEx, UPS, and DHL\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eWe dispatch orders within 5 business days.\u003c\/li\u003e\n\u003cli\u003eWe support 30-day returns on this product.\u003c\/li\u003e\n\u003cli\u003eContact our sales team for stock availability and lead time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What temperature probes does the TM5SAI2PH support?\u003c\/strong\u003e\u003cbr\u003eA: It supports Pt 100 and Pt 1000 temperature probes over -200 to 850 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the resolution of this module?\u003c\/strong\u003e\u003cbr\u003eA: The module provides 16-bit resolution with a measurement resolution of 0.1 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the module isolate the two input channels?\u003c\/strong\u003e\u003cbr\u003eA: It provides 500 Vrms AC isolation between channel and bus, with no insulation between channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which controllers work with the TM5SAI2PH?\u003c\/strong\u003e\u003cbr\u003eA: It works with Modicon M258 and LMC058 logic controllers, as well as motion controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The module operates from 0 to 55 °C without derating when mounted vertically.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this product new and in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we offer brand new original units and keep stock available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days using DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We accept returns within 30 days of delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48567831593121,"sku":"TM5SAI2PH","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/TM5SAI2PH.jpg?v=1793607586","url":"https:\/\/www.autonexcontrol.com\/products\/tm5sai2ph-schneider-analog-input-module-2-channel-pt100","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}