{"product_id":"tc-odx161-honeywell-16-point-discrete-output-module","title":"TC-ODX161 Honeywell 16-Point Discrete Output Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell TC-ODX161 10-30 VDC 16-Point Diagnostic Discrete Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eTC-ODX161\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Diagnostic Discrete Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Points:\u003c\/strong\u003e 16, arranged as 8 points per common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Range:\u003c\/strong\u003e 19.2–30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer Point Current Rating:\u003c\/strong\u003e 2.0 A maximum at 30°C, 1.0 A maximum at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer Module Current Rating:\u003c\/strong\u003e 8.0 A maximum at 30°C, 4.0 A maximum at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current:\u003c\/strong\u003e 4 A for 10 ms each, repeatable every 1 second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum On-State Current:\u003c\/strong\u003e 1.0 mA per output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum On-State Voltage Drop:\u003c\/strong\u003e 1.2 VDC at 2.0 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Overload Short\/Trip:\u003c\/strong\u003e 6 A for 350 ms minimum, 8 A for 180 ms minimum, 10 A for 120 ms minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Load Detection:\u003c\/strong\u003e 5 VDC minimum at 3 mA minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Verification:\u003c\/strong\u003e 5 VDC minimum on detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Test:\u003c\/strong\u003e 1 ms or 2 ms user selectable pulse width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Off-State Leakage Current:\u003c\/strong\u003e 1.0 mA per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault State:\u003c\/strong\u003e User definable On or Off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal Delay Off to On:\u003c\/strong\u003e 1.0 ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal Delay On to Off:\u003c\/strong\u003e 5.0 ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 5.1 W maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e See Module Power Consumption Data, page 46\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 1500 VAC RMS output to backplane and between commons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Terminal Blocks:\u003c\/strong\u003e TC-TBCH, 36-position terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the on-state voltage range of the Honeywell TC-ODX161?\u003c\/strong\u003e\u003cbr\u003eA: The module supports 19.2–30 VDC for each output point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many outputs does the TC-ODX161 provide?\u003c\/strong\u003e\u003cbr\u003eA: It provides 16 diagnostic discrete output points, grouped as 8 points per common.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum current per point?\u003c\/strong\u003e\u003cbr\u003eA: Each point handles 2.0 A maximum at 30°C and 1.0 A maximum at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum current per module?\u003c\/strong\u003e\u003cbr\u003eA: The module handles 8.0 A maximum at 30°C and 4.0 A maximum at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What diagnostic functions does this module offer?\u003c\/strong\u003e\u003cbr\u003eA: It offers thermal overload short\/trip, no load, output verification, and pulse test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the surge current rating?\u003c\/strong\u003e\u003cbr\u003eA: It delivers 4 A for 10 ms each, repeatable every 1 second.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum on-state current?\u003c\/strong\u003e\u003cbr\u003eA: The minimum on-state current is 1.0 mA per output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum on-state voltage drop?\u003c\/strong\u003e\u003cbr\u003eA: The maximum on-state voltage drop is 1.2 VDC at 2.0 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum off-state leakage current?\u003c\/strong\u003e\u003cbr\u003eA: The maximum off-state leakage current is 1.0 mA per point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the output signal delay?\u003c\/strong\u003e\u003cbr\u003eA: Off to on is 1.0 ms maximum, and on to off is 5.0 ms maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the isolation voltage?\u003c\/strong\u003e\u003cbr\u003eA: The isolation voltage is 1500 VAC RMS output to backplane and between commons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What terminal block does this module use?\u003c\/strong\u003e\u003cbr\u003eA: It uses the TC-TBCH 36-position terminal block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How much power does the module dissipate?\u003c\/strong\u003e\u003cbr\u003eA: The module dissipates 5.1 W maximum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48075359617185,"sku":"TC-ODX161","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/TC-ODX161.jpg?v=1791964035","url":"https:\/\/www.autonexcontrol.com\/products\/tc-odx161-honeywell-16-point-discrete-output-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}