{"product_id":"tc-odx081-honeywell-8-point-120-vac-discrete-output-module","title":"TC-ODX081 Honeywell 8-Point 120 VAC Discrete Output Module","description":"\u003ch2\u003e\u003cstrong\u003eTC-ODX081 Honeywell 120 VAC 8-Point Diagnostic Discrete Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eTC-ODX081\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Diagnostic Discrete Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs per Module:\u003c\/strong\u003e 8 points with 4 points per common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Range:\u003c\/strong\u003e 74 to 132 VAC at 47 to 63 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChange of State:\u003c\/strong\u003e Software configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current per Point:\u003c\/strong\u003e 1 A maximum at 30°C and 0.5 A maximum at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current per Module:\u003c\/strong\u003e 8 A maximum at 30°C and 4 A maximum at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current:\u003c\/strong\u003e 8 A for 50 ms each at 30°C, repeatable every 2 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current at 60°C:\u003c\/strong\u003e 5 A for 50 ms each, repeatable every 2 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Current Minimum:\u003c\/strong\u003e 10 mA per output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Drop Maximum:\u003c\/strong\u003e 2.5 V peak at 0.5 A and 3.0 V peak at 1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Inhibit Voltage:\u003c\/strong\u003e 25 V peak at zero crossing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Leakage Current Maximum:\u003c\/strong\u003e 3 mA per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 13.8 watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e Channel to channel and user to system both tested at 2546 VDC for 1 second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Terminal Blocks:\u003c\/strong\u003e TC-TBNH 20-position terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload\/Short Trip:\u003c\/strong\u003e Trips at 12 A for 500 µs minimum to protect the output circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Load Detection:\u003c\/strong\u003e Detects 74 to 132 VAC at 12 µA minimum on-state current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Verification:\u003c\/strong\u003e Confirms 74 to 132 VAC on detection at 12 µA minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Test:\u003c\/strong\u003e Offers 100 µs increment user selectable width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Test Delay:\u003c\/strong\u003e Provides 100 µs increment user selectable time delay from zero cross\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Signal Delay\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff to On Maximum:\u003c\/strong\u003e 9.3 ms at 60 Hz and 11 ms at 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn to Off Maximum:\u003c\/strong\u003e 9.3 ms at 60 Hz and 11 ms at 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e Refer to module power consumption data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module in a compatible Honeywell TC series backplane slot\u003c\/li\u003e\n\u003cli\u003eUse the TC-TBNH 20-position terminal block for all field wiring connections\u003c\/li\u003e\n\u003cli\u003eVerify load current stays within the per point and per module ratings\u003c\/li\u003e\n\u003cli\u003eCheck ambient temperature to confirm the correct current derating applies\u003c\/li\u003e\n\u003cli\u003eConfirm isolation voltage integrity before energizing the system\u003c\/li\u003e\n\u003cli\u003eConfigure change of state and pulse test settings through the software interface\u003c\/li\u003e\n\u003cli\u003eTest overload and no load diagnostics after commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Honeywell \u003cstrong\u003eTC-ODX081\u003c\/strong\u003e diagnostic discrete output module\u003c\/li\u003e\n\u003cli\u003eOne TC-TBNH 20-position terminal block\u003c\/li\u003e\n\u003cli\u003eInstallation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Methods\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx\u003c\/li\u003e\n\u003cli\u003eUPS\u003c\/li\u003e\n\u003cli\u003eDHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many outputs does the TC-ODX081 support?\u003c\/strong\u003e\u003cbr\u003eA: It provides 8 points with 4 points per common.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the on-state voltage range for this module?\u003c\/strong\u003e\u003cbr\u003eA: The module operates from 74 to 132 VAC at 47 to 63 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum output current per point?\u003c\/strong\u003e\u003cbr\u003eA: It handles 1 A at 30°C and 0.5 A at 60°C per point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What diagnostic functions does this module offer?\u003c\/strong\u003e\u003cbr\u003eA: It provides overload\/short trip, no load, output verification, and pulse test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the off-state leakage current?\u003c\/strong\u003e\u003cbr\u003eA: The off-state leakage current is 3 mA maximum per point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which terminal block works with this module?\u003c\/strong\u003e\u003cbr\u003eA: The TC-TBNH 20-position terminal block is the correct choice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply brand new original products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have stock available?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we have stock available for immediate order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days after order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping carriers do you use?\u003c\/strong\u003e\u003cbr\u003eA: We use common carriers such as DHL, FedEx, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support returns within 30 days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48075326226593,"sku":"TC-ODX081","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/TC-ODX081.jpg?v=1791963113","url":"https:\/\/www.autonexcontrol.com\/products\/tc-odx081-honeywell-8-point-120-vac-discrete-output-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}