{"product_id":"tc-odd321-honeywell-24-vdc-output-module","title":"TC-ODD321 Honeywell 24 VDC Output Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell TC-ODD321 24 VDC 32-Point Discrete Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eTC-ODD321\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Discrete Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e 32, arranged as 16 points per common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 10–31.2 VDC at 50°C with linear derating, 10–28 VDC at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer Point Current Rating:\u003c\/strong\u003e 0.5 A maximum at 50°C with linear derating, 0.35 A maximum at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer Module Current Rating:\u003c\/strong\u003e 16 A maximum at 50°C with linear derating, 10 A maximum at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current:\u003c\/strong\u003e 1 A for 10 ms each, repeatable every 2 seconds at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlash On Time:\u003c\/strong\u003e 100 µs target, 150 µs maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum On-State Load Current:\u003c\/strong\u003e 3.0 mA per output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum On-State Voltage Drop:\u003c\/strong\u003e 1 VDC at rated current per point, 3 VDC for IEC 1131-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Off-State Leakage Current:\u003c\/strong\u003e 0.5 mA per point, 1 mA per point for IEC 1131-2 at 0.25 A output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Fault States per Point:\u003c\/strong\u003e Hold Last State, ON, or OFF, with OFF as default\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable States in Program Mode per Point:\u003c\/strong\u003e Hold Last State, ON, or OFF, with OFF as default\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing:\u003c\/strong\u003e Not protected, fused IFM is recommended to protect outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Polarity Protection:\u003c\/strong\u003e None, incorrect wiring may damage outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Delay Time Off to On:\u003c\/strong\u003e 1.0 ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Delay Time On to Off:\u003c\/strong\u003e 1.0 ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 6.1 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e See Module Power Consumption Data, page 46\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage Group to Group:\u003c\/strong\u003e 100% tested at 2546 VDC for 1 second, 250 VAC maximum continuous voltage between groups\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage User to System:\u003c\/strong\u003e 100% tested at 2546 VDC for 1 second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Terminal Blocks:\u003c\/strong\u003e TC-TBCH, 36-position terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance and Thermal Derating\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module supports an output range from \u003cspan style=\"color: #c0392b;\"\u003e10 VDC to 31.2 VDC at 50°C\u003c\/span\u003e with linear derating.\u003c\/li\u003e\n\u003cli\u003eAt 60°C, the output range narrows to \u003cspan style=\"color: #c0392b;\"\u003e10 VDC to 28 VDC\u003c\/span\u003e for safe operation.\u003c\/li\u003e\n\u003cli\u003eEach point handles 0.5 A at 50°C with linear derating and 0.35 A at 60°C.\u003c\/li\u003e\n\u003cli\u003eThe full module handles 16 A at 50°C with linear derating and 10 A at 60°C.\u003c\/li\u003e\n\u003cli\u003eSurge current reaches 1 A for 10 ms, and it repeats every 2 seconds at 60°C.\u003c\/li\u003e\n\u003cli\u003eFlash on time targets 100 µs with a 150 µs maximum for fast switching.\u003c\/li\u003e\n\u003cli\u003eMinimum on-state load current stays at 3.0 mA per output.\u003c\/li\u003e\n\u003cli\u003eOff-state leakage remains below 0.5 mA per point for clean channel separation.\u003c\/li\u003e\n\u003cli\u003eGroup-to-group isolation holds 250 VAC maximum continuous voltage between groups.\u003c\/li\u003e\n\u003cli\u003eBoth group-to-group and user-to-system isolation pass 2546 VDC testing for 1 second.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eTC-ODD321\u003c\/strong\u003e in a compatible Honeywell I\/O rack or control panel slot.\u003c\/li\u003e\n\u003cli\u003eUse the TC-TBCH 36-position terminal block for field wiring connections.\u003c\/li\u003e\n\u003cli\u003eAdd a fused IFM to protect outputs because the module has no internal fusing.\u003c\/li\u003e\n\u003cli\u003eCheck wiring polarity carefully because the module lacks reverse polarity protection.\u003c\/li\u003e\n\u003cli\u003eApply linear derating for current and voltage when panel temperature exceeds 50°C.\u003c\/li\u003e\n\u003cli\u003eSet fault states and program mode states per point before system commissioning.\u003c\/li\u003e\n\u003cli\u003eConfirm the 1.0 ms delay times fit your control loop timing requirements.\u003c\/li\u003e\n\u003cli\u003eReview power dissipation of 6.1 W when planning panel thermal management.\u003c\/li\u003e\n\u003cli\u003eTest group-to-group and user-to-system isolation before applying full field power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Honeywell \u003cstrong\u003eTC-ODD321\u003c\/strong\u003e 32-Point Discrete Output Module\u003c\/li\u003e\n\u003cli\u003e1 x TC-TBCH 36-position terminal block\u003c\/li\u003e\n\u003cli\u003e1 x Protective packaging for safe transport\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship by FedEx, UPS, and DHL according to your delivery preference.\u003c\/li\u003e\n\u003cli\u003eWe keep this module in stock and dispatch orders within 5 days.\u003c\/li\u003e\n\u003cli\u003eWe offer a 30-day return policy for eligible purchases.\u003c\/li\u003e\n\u003cli\u003eWe supply new original units for industrial replacement and project use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the output voltage range of the Honeywell TC-ODD321?\u003c\/strong\u003e\u003cbr\u003eA: It supports 10–31.2 VDC at 50°C with linear derating and 10–28 VDC at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many outputs does the TC-ODD321 provide?\u003c\/strong\u003e\u003cbr\u003eA: It provides 32 discrete outputs, grouped as 16 points per common.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum current per point?\u003c\/strong\u003e\u003cbr\u003eA: Each point handles 0.5 A maximum at 50°C with linear derating and 0.35 A maximum at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum current per module?\u003c\/strong\u003e\u003cbr\u003eA: The module handles 16 A maximum at 50°C with linear derating and 10 A maximum at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the surge current rating?\u003c\/strong\u003e\u003cbr\u003eA: It delivers 1 A for 10 ms each, repeatable every 2 seconds at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the flash on time?\u003c\/strong\u003e\u003cbr\u003eA: The flash on time is 100 µs target with a 150 µs maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum on-state load current?\u003c\/strong\u003e\u003cbr\u003eA: The minimum on-state load current is 3.0 mA per output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum off-state leakage current?\u003c\/strong\u003e\u003cbr\u003eA: The maximum off-state leakage current is 0.5 mA per point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this module have internal fusing?\u003c\/strong\u003e\u003cbr\u003eA: No, it is not protected, and a fused IFM is recommended to protect outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this module have reverse polarity protection?\u003c\/strong\u003e\u003cbr\u003eA: No, incorrect wiring may damage the outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the output delay time?\u003c\/strong\u003e\u003cbr\u003eA: Both off-to-on and on-to-off delays are 1.0 ms maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the isolation voltage?\u003c\/strong\u003e\u003cbr\u003eA: Group-to-group and user-to-system isolation are 100% tested at 2546 VDC for 1 second.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What terminal block does this module use?\u003c\/strong\u003e\u003cbr\u003eA: It uses the TC-TBCH 36-position terminal block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How much power does the module dissipate?\u003c\/strong\u003e\u003cbr\u003eA: The module dissipates 6.1 W.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48075363156129,"sku":"TC-ODD321","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/TC-ODD321-1.jpg?v=1791964190","url":"https:\/\/www.autonexcontrol.com\/products\/tc-odd321-honeywell-24-vdc-output-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}