{"product_id":"tc-oda161-honeywell-120-220-vac-output-module","title":"TC-ODA161 Honeywell 120\/220 VAC Output Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell TC-ODA161 16-Point Discrete Output Module for 120\/220 VAC Systems\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eTC-ODA161\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Discrete Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e 16 points, arranged as 4 points per common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 74–265 VAC, 47–63 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer Point Current Rating:\u003c\/strong\u003e 2 A maximum at 30°C, 1 A maximum at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer Module Current Rating:\u003c\/strong\u003e 5 A maximum at 30°C, 4 A maximum at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current:\u003c\/strong\u003e 20 A for 43 ms each, repeatable every 2 seconds at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Load Current:\u003c\/strong\u003e 10 mA per output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum On-State Voltage Drop:\u003c\/strong\u003e 1.5 V peak at 2 A, 6 V peak at load current below 50 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Off-State Leakage Current:\u003c\/strong\u003e 3 mA per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Delay Time:\u003c\/strong\u003e Off to on and on to off both 1 ms plus 1\/2 cycle maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Fault States per Point:\u003c\/strong\u003e Hold Last State, ON, or OFF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable States in Program Mode per Point:\u003c\/strong\u003e Hold Last State, ON, or OFF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e See Module Power Consumption Data, page 46\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 6.5 watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e Channel to channel and user to system both 100% tested at 2546 VDC for 1 second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Inhibit Voltage:\u003c\/strong\u003e Zero crossing 60 V peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Terminal Blocks:\u003c\/strong\u003e TC-TBNH, 20-position terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance and Environmental Durability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module supports a wide AC voltage range from \u003cspan style=\"color: #c0392b;\"\u003e74 VAC to 265 VAC\u003c\/span\u003e for global industrial power systems.\u003c\/li\u003e\n\u003cli\u003eIts frequency response covers \u003cspan style=\"color: #c0392b;\"\u003e47 Hz to 63 Hz\u003c\/span\u003e, matching standard AC supply networks.\u003c\/li\u003e\n\u003cli\u003eEach output handles up to 2 A at 30°C, which suits many solenoid, relay, and indicator loads.\u003c\/li\u003e\n\u003cli\u003eThe surge rating reaches 20 A for 43 ms, and it repeats every 2 seconds at 60°C.\u003c\/li\u003e\n\u003cli\u003eMinimum load current stays at 10 mA per output for stable switching behavior.\u003c\/li\u003e\n\u003cli\u003eOff-state leakage remains below 3 mA per point to reduce false triggering.\u003c\/li\u003e\n\u003cli\u003eIsolation testing at 2546 VDC for 1 second protects operators and connected equipment.\u003c\/li\u003e\n\u003cli\u003eThe zero crossing inhibit voltage reaches 60 V peak for noise-sensitive installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eTC-ODA161\u003c\/strong\u003e in a compatible Honeywell I\/O rack or control panel slot.\u003c\/li\u003e\n\u003cli\u003eUse the TC-TBNH 20-position terminal block for field wiring connections.\u003c\/li\u003e\n\u003cli\u003eKeep AC output wiring separated from low-level signal cables to reduce electrical noise.\u003c\/li\u003e\n\u003cli\u003eConfirm the load current stays within 2 A per point at 30°C or 1 A per point at 60°C.\u003c\/li\u003e\n\u003cli\u003eCheck the backplane power budget using the Module Power Consumption Data on page 46.\u003c\/li\u003e\n\u003cli\u003eSet fault states and program mode states per point before system commissioning.\u003c\/li\u003e\n\u003cli\u003eVerify the output delay time fits your control loop timing requirements.\u003c\/li\u003e\n\u003cli\u003eTest channel-to-channel and user-to-system isolation before applying full field power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Honeywell \u003cstrong\u003eTC-ODA161\u003c\/strong\u003e 16-Point Discrete Output Module\u003c\/li\u003e\n\u003cli\u003e1 x TC-TBNH 20-position terminal block\u003c\/li\u003e\n\u003cli\u003e1 x Protective packaging for safe transport\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship by FedEx, UPS, and DHL according to your delivery preference.\u003c\/li\u003e\n\u003cli\u003eWe keep this module in stock and dispatch orders within 5 days.\u003c\/li\u003e\n\u003cli\u003eWe offer a 30-day return policy for eligible purchases.\u003c\/li\u003e\n\u003cli\u003eWe supply new original units for industrial replacement and project use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the output voltage range of the Honeywell TC-ODA161?\u003c\/strong\u003e\u003cbr\u003eA: The module supports 74–265 VAC at 47–63 Hz for each output point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many outputs does the TC-ODA161 provide?\u003c\/strong\u003e\u003cbr\u003eA: It provides 16 discrete outputs, grouped as 4 points per common.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum current per output point?\u003c\/strong\u003e\u003cbr\u003eA: Each point handles 2 A maximum at 30°C and 1 A maximum at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum current per module?\u003c\/strong\u003e\u003cbr\u003eA: The module handles 5 A maximum at 30°C and 4 A maximum at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the surge current rating?\u003c\/strong\u003e\u003cbr\u003eA: It delivers 20 A for 43 ms each, repeatable every 2 seconds at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum load current?\u003c\/strong\u003e\u003cbr\u003eA: The minimum load current is 10 mA per output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum off-state leakage current?\u003c\/strong\u003e\u003cbr\u003eA: The maximum off-state leakage current is 3 mA per point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the output delay time?\u003c\/strong\u003e\u003cbr\u003eA: Both off-to-on and on-to-off delays are 1 ms plus 1\/2 cycle maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What terminal block does this module use?\u003c\/strong\u003e\u003cbr\u003eA: It uses the TC-TBNH 20-position terminal block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How much power does the module dissipate?\u003c\/strong\u003e\u003cbr\u003eA: The module dissipates 6.5 watts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48075334516897,"sku":"TC-ODA161","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/TC-ODA161.jpg?v=1791963274","url":"https:\/\/www.autonexcontrol.com\/products\/tc-oda161-honeywell-120-220-vac-output-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}