{"product_id":"tc-fod161-honeywell-24vdc-digital-output-module-16-ch","title":"TC-FOD161 Honeywell 24Vdc Digital Output Module 16-Ch","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell TC-FOD161 Digital Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eTC-FOD161\u003c\/strong\u003e – 24 Vdc Source Digital Output (Protected).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Configuration:\u003c\/strong\u003e 16 channels in one non-isolated group. No isolation between individual channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage:\u003c\/strong\u003e 10 Vdc minimum, 24 Vdc nominal, 31.2 Vdc maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Current:\u003c\/strong\u003e 1 mA minimum per channel, 500 mA maximum per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Drop \u0026amp; Leakage:\u003c\/strong\u003e Maximum voltage drop 0.5 Vdc; leakage current ≤ 0.5 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current:\u003c\/strong\u003e 1.5 A for 50 ms, repeatable every 2 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Withstand:\u003c\/strong\u003e 100% tested at 850 Vdc for 1 second (user to system).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Delay Times:\u003c\/strong\u003e OFF to ON ≤ 0.5 ms; ON to OFF ≤ 1.0 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexbus Current:\u003c\/strong\u003e 80 mA maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Thermal:\u003c\/strong\u003e Dissipation 5W @ 31.2 Vdc; Thermal 17 BTU\/hr @ 31.2 Vdc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators:\u003c\/strong\u003e 16 yellow channel status LEDs for clear visual feedback.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Specifications \u0026amp; Power Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal DC Power:\u003c\/strong\u003e 19.2–31.2 Vdc (5% ac ripple), current 80 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (HxWxD):\u003c\/strong\u003e 69 mm x 94 mm x 80 mm (2.72 in x 3.7 in x 3.20 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Temperature:\u003c\/strong\u003e Operational 0 to 55 °C; Storage -40 to 85 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5 to 95% non-condensing relative humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock (Operating):\u003c\/strong\u003e 30g peak, 11 ms pulse; Non-operating: 50g peak.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 5g @ 10–500 Hz per IEC 68-2-6.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductors:\u003c\/strong\u003e 12 gauge (4 mm²) stranded max, insulation 3\/64 inch, 90°C min.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 4–7 inch-pounds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Certifications:\u003c\/strong\u003e Groups A, B, C, D; Class I Division 2; Class I Zone 2 Group IIC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the TC-FOD161 brand new?\u003c\/strong\u003e Yes, we supply only \u003cspan style=\"color: #cc0000;\"\u003e100% brand new original\u003c\/span\u003e Honeywell modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have stock?\u003c\/strong\u003e Yes, we keep the \u003cstrong\u003eTC-FOD161\u003c\/strong\u003e in stock and ready for immediate order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the lead time?\u003c\/strong\u003e We ship all orders within 5 business days after confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich carriers do you use?\u003c\/strong\u003e We ship via FedEx, UPS, or DHL – you can choose your preference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return the module?\u003c\/strong\u003e Yes, we support returns within 30 days of delivery (conditions apply).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it have channel-to-channel isolation?\u003c\/strong\u003e No, the 16 channels share a common group without isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum surge current?\u003c\/strong\u003e 1.5 A for 50 ms, repeating every 2 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the OFF-state leakage?\u003c\/strong\u003e Maximum leakage current is 0.5 mA per channel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 20px; font-size: 0.95rem;\"\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\" style=\"color: #0066cc; text-decoration: underline;\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\" style=\"color: #0066cc; text-decoration: underline;\"\u003e+86 153 9242 9628\u003c\/a\u003e \u003cbr\u003e\u003cstrong\u003ePartner NexAuto Technology Limited:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46924106137761,"sku":"TC-FOD161","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/TC-FOD161.jpg?v=1787628790","url":"https:\/\/www.autonexcontrol.com\/products\/tc-fod161-honeywell-24vdc-digital-output-module-16-ch","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}