{"product_id":"tc-fccr01-honeywell-controlnet-gateway-redundant","title":"TC-FCCR01 Honeywell ControlNet Gateway Redundant","description":"\u003ch2\u003e\u003cstrong\u003eTC-FCCR01 Honeywell ControlNet Gateway, Redundant Media\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: Honeywell\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003eTC-FCCR01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCategory: ControlNet Gateway\u003c\/li\u003e\n\u003cli\u003eI\/O Capacity: 8 modules\u003c\/li\u003e\n\u003cli\u003eCommunication Rate: 5M bit\/s\u003c\/li\u003e\n\u003cli\u003eSupports Redundant ControlNet Cabling: Yes\u003c\/li\u003e\n\u003cli\u003eConnector Screw Torque: 7-9 inch-pounds\u003c\/li\u003e\n\u003cli\u003eInput Voltage Rating: 24V dc nominal\u003c\/li\u003e\n\u003cli\u003eInput Voltage Range: 19.2V to 31.2V dc, includes 5% ac ripple\u003c\/li\u003e\n\u003cli\u003eFlexbus Output Current: 640mA maximum at 5V dc\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: 500V ac between user power and flexbus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower and Thermal Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply Requirement: Use a Safety Extra Low Voltage (SELV) or Protected Extra Low Voltage (PELV) supply to comply with CE Low Voltage Directives\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 400mA maximum from external 24V supply\u003c\/li\u003e\n\u003cli\u003ePower Dissipation: 4.6W maximum at 19.2V dc\u003c\/li\u003e\n\u003cli\u003eThermal Dissipation: 15.7 BTU\/hr at 19.2V dc\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndicators and Programming Ports\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComm A Indicator: Red and green for channel A\u003c\/li\u003e\n\u003cli\u003eComm B Indicator: Red and green for channel B\u003c\/li\u003e\n\u003cli\u003eI\/O Status Indicator: Red and green\u003c\/li\u003e\n\u003cli\u003eProgramming Ports: 1 RJ-45 Network Access Port (NAP) for use with ControlNet programming cable, such as 1786-CP cable\u003c\/li\u003e\n\u003cli\u003eProgramming Port Note: This port is not supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions HxWxD: 87mm x 94mm x 69mm (3.4in x 3.7in x 2.7in)\u003c\/li\u003e\n\u003cli\u003eOperational Temperature: 0 to 55℃ (32 to 131℉)\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40 to 85℃ (-40 to 185℉)\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5 to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003eShock, Operating: 30g peak acceleration, 11(±1)ms pulse width\u003c\/li\u003e\n\u003cli\u003eShock, Non-operating: 50g peak acceleration, 11(±1)ms pulse width\u003c\/li\u003e\n\u003cli\u003eVibration: Tested 5g at 10-500Hz per IEC 68-2-6\u003c\/li\u003e\n\u003cli\u003eControlNet Cable: Belden RG-6\/U Quad Shield\u003c\/li\u003e\n\u003cli\u003ePower Conductors Type: Copper, stranded or solid\u003c\/li\u003e\n\u003cli\u003eWire Size: 12 gauge (4mm2) stranded maximum, 3\/64 (1.2mm) inch insulation maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eTC-FCCR01\u003c\/strong\u003e in a panel that allows access to all connectors\u003c\/li\u003e\n\u003cli\u003eUse a SELV or PELV power supply to meet CE Low Voltage Directives\u003c\/li\u003e\n\u003cli\u003eConfirm the input voltage stays between 19.2V and 31.2V dc\u003c\/li\u003e\n\u003cli\u003eTighten connector screws to 7-9 inch-pounds for reliable contact\u003c\/li\u003e\n\u003cli\u003eUse Belden RG-6\/U Quad Shield cable for ControlNet wiring\u003c\/li\u003e\n\u003cli\u003eConnect both channel A and channel B for redundant media operation\u003c\/li\u003e\n\u003cli\u003eKeep the flexbus output current at or below 640mA at 5V dc\u003c\/li\u003e\n\u003cli\u003eCheck the Comm A, Comm B, and I\/O status indicators after power-up\u003c\/li\u003e\n\u003cli\u003eUse the RJ-45 NAP port only for supported programming tasks\u003c\/li\u003e\n\u003cli\u003eMaintain 5 to 95% non-condensing humidity around the module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Honeywell \u003cstrong\u003eTC-FCCR01\u003c\/strong\u003e ControlNet Gateway\u003c\/li\u003e\n\u003cli\u003e1 x Installation guide\u003c\/li\u003e\n\u003cli\u003e1 x Protective packing box\u003c\/li\u003e\n\u003cli\u003eShipping Methods: FedEx, UPS, and DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: What is the TC-FCCR01?\u003c\/li\u003e\n\u003cli\u003eA: It is a ControlNet gateway with redundant media support from Honeywell.\u003c\/li\u003e\n\u003cli\u003eQ: How many I\/O modules does it support?\u003c\/li\u003e\n\u003cli\u003eA: It supports up to 8 modules.\u003c\/li\u003e\n\u003cli\u003eQ: What is the communication rate?\u003c\/li\u003e\n\u003cli\u003eA: The communication rate is 5M bit\/s.\u003c\/li\u003e\n\u003cli\u003eQ: Does it support redundant ControlNet cabling?\u003c\/li\u003e\n\u003cli\u003eA: Yes, it supports redundant ControlNet cabling.\u003c\/li\u003e\n\u003cli\u003eQ: What is the input voltage rating?\u003c\/li\u003e\n\u003cli\u003eA: The input voltage rating is 24V dc nominal.\u003c\/li\u003e\n\u003cli\u003eQ: What is the input voltage range?\u003c\/li\u003e\n\u003cli\u003eA: The range is 19.2V to 31.2V dc, including 5% ac ripple.\u003c\/li\u003e\n\u003cli\u003eQ: What power supply should I use?\u003c\/li\u003e\n\u003cli\u003eA: Use a SELV or PELV supply to comply with CE Low Voltage Directives.\u003c\/li\u003e\n\u003cli\u003eQ: What is the power consumption?\u003c\/li\u003e\n\u003cli\u003eA: It draws 400mA maximum from an external 24V supply.\u003c\/li\u003e\n\u003cli\u003eQ: What is the power dissipation?\u003c\/li\u003e\n\u003cli\u003eA: Power dissipation is 4.6W maximum at 19.2V dc.\u003c\/li\u003e\n\u003cli\u003eQ: What is the thermal dissipation?\u003c\/li\u003e\n\u003cli\u003eA: Thermal dissipation is 15.7 BTU\/hr at 19.2V dc.\u003c\/li\u003e\n\u003cli\u003eQ: What indicators does it have?\u003c\/li\u003e\n\u003cli\u003eA: It has Comm A, Comm B, and I\/O status indicators, all red and green.\u003c\/li\u003e\n\u003cli\u003eQ: What programming port does it use?\u003c\/li\u003e\n\u003cli\u003eA: It has 1 RJ-45 Network Access Port for ControlNet programming cable, but it is not supported.\u003c\/li\u003e\n\u003cli\u003eQ: What are the dimensions?\u003c\/li\u003e\n\u003cli\u003eA: The dimensions are 87mm x 94mm x 69mm.\u003c\/li\u003e\n\u003cli\u003eQ: What is the operating temperature range?\u003c\/li\u003e\n\u003cli\u003eA: The operating temperature range is 0 to 55℃.\u003c\/li\u003e\n\u003cli\u003eQ: What is the storage temperature range?\u003c\/li\u003e\n\u003cli\u003eA: The storage temperature range is -40 to 85℃.\u003c\/li\u003e\n\u003cli\u003eQ: What is the relative humidity range?\u003c\/li\u003e\n\u003cli\u003eA: The range is 5 to 95% non-condensing.\u003c\/li\u003e\n\u003cli\u003eQ: What cable does ControlNet use?\u003c\/li\u003e\n\u003cli\u003eA: ControlNet uses Belden RG-6\/U Quad Shield cable.\u003c\/li\u003e\n\u003cli\u003eQ: What is the isolation voltage?\u003c\/li\u003e\n\u003cli\u003eA: Isolation is 500V ac between user power and flexbus.\u003c\/li\u003e\n\u003cli\u003eQ: What connector screw torque should I use?\u003c\/li\u003e\n\u003cli\u003eA: Tighten connector screws to 7-9 inch-pounds.\u003c\/li\u003e\n\u003cli\u003eQ: Is the product new and original?\u003c\/li\u003e\n\u003cli\u003eA: Yes, the product is brand new and original.\u003c\/li\u003e\n\u003cli\u003eQ: Do you have stock?\u003c\/li\u003e\n\u003cli\u003eA: Yes, we have stock available.\u003c\/li\u003e\n\u003cli\u003eQ: How fast do you ship?\u003c\/li\u003e\n\u003cli\u003eA: We ship within 5 days.\u003c\/li\u003e\n\u003cli\u003eQ: What shipping methods do you use?\u003c\/li\u003e\n\u003cli\u003eA: We commonly use DHL, FedEx, and UPS.\u003c\/li\u003e\n\u003cli\u003eQ: What is the return policy?\u003c\/li\u003e\n\u003cli\u003eA: We support returns within 30 days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor inquiries, please contact us at \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48107557453985,"sku":"TC-FCCR01","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/TC-FCCR01.jpg?v=1792141955","url":"https:\/\/www.autonexcontrol.com\/products\/tc-fccr01-honeywell-controlnet-gateway-redundant","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}