{"product_id":"s30a-7111dp-sick-s3000-profinet-safety-laser-scanner-7m-range","title":"S30A-7111DP SICK S3000 PROFINET Safety Laser Scanner 7m Range","description":"\u003ch2\u003e\u003cstrong\u003eS30A-7111DP SICK S3000 PROFINET IO Safety Laser Scanner – 7 m Protective Field, 190° Scan Angle\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e SICK Sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eS30A-7111DP\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e S3000 PROFINET IO Professional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective field range:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e7 m\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarning field range:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e49 m\u003c\/span\u003e (20 m at 20% reflectivity)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistance measuring range:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e49 m\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScanning angle:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e190°\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution (configurable):\u003c\/strong\u003e 30 mm, 40 mm, 50 mm, 70 mm, 150 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAngular resolution:\u003c\/strong\u003e 0.5°, 0.25° (depending on range and resolution)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e60 ms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective field supplement:\u003c\/strong\u003e 100 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of field sets:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of fields:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of monitoring cases:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of simultaneously monitored protective fields:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of field set:\u003c\/strong\u003e Dual field sets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple samplings:\u003c\/strong\u003e 2 to 16, configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelay of automatic reset:\u003c\/strong\u003e 120 ms to 4,920 ms, configurable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety-Related Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Type 3 (IEC 61496)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety integrity level:\u003c\/strong\u003e SIL 2 (IEC 61508)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Category 3 (EN ISO 13849)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerformance level:\u003c\/strong\u003e PL d (EN ISO 13849)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePFHD:\u003c\/strong\u003e 8.0 x 10\u003csup\u003e-8\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMission time (TM):\u003c\/strong\u003e 20 years (EN ISO 13849)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe state in the event of a fault:\u003c\/strong\u003e The safety-related data is logic 0.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctions \u0026amp; Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestart interlock:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple sampling:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring case switching:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimultaneous monitoring:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic protective field switching:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContour as a reference:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated configuration memory:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured data output:\u003c\/strong\u003e Via RS-422\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus connection:\u003c\/strong\u003e Copper conductor (2 female connectors for RJ-45 push-pull plug)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply connection:\u003c\/strong\u003e System plug with or without connecting cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration and diagnostics interface:\u003c\/strong\u003e RS-232\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission rate:\u003c\/strong\u003e 9.6 kBaud, 19.2 kBaud, 38.4 kBaud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFieldbus:\u003c\/strong\u003e PROFINET PROFIsafe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformance:\u003c\/strong\u003e Conformance Class B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCycle time:\u003c\/strong\u003e 4, 8, 16, 32 ms, etc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 155 mm x 185 mm x 160 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.3 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Aluminum die cast\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing color:\u003c\/strong\u003e RAL 1021 (yellow)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront screen material:\u003c\/strong\u003e Polycarbonate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront screen surface finish:\u003c\/strong\u003e Outside with scratch-resistant coating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure rating:\u003c\/strong\u003e IP65 (EN 60529)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient operating temperature:\u003c\/strong\u003e –10 °C to +50 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e –25 °C to +50 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock resistance:\u003c\/strong\u003e IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous shock:\u003c\/strong\u003e 50 m\/s², 11 ms; 100 m\/s², 16 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the scanner indoors on a stable surface using the aluminum die cast housing.\u003c\/li\u003e\n\u003cli\u003eConnect the device only within a network that has a corresponding PROFINET controller.\u003c\/li\u003e\n\u003cli\u003eUse the system plug with or without connecting cable for the supply connection.\u003c\/li\u003e\n\u003cli\u003eAlign the scanning plane to cover the hazardous area up to 7 m.\u003c\/li\u003e\n\u003cli\u003eConfigure resolution, multiple samplings, and monitoring cases before operation.\u003c\/li\u003e\n\u003cli\u003eEnsure the IP65 rating by sealing all connections properly.\u003c\/li\u003e\n\u003cli\u003eVerify the ambient operating temperature stays between –10 °C and +50 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x SICK \u003cstrong\u003eS30A-7111DP\u003c\/strong\u003e Safety Laser Scanner\u003c\/li\u003e\n\u003cli\u003e1 x Sensor head without system plug\u003c\/li\u003e\n\u003cli\u003e1 x Quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Returns\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eWe dispatch your order within 5 days.\u003c\/li\u003e\n\u003cli\u003eWe offer a 30-day return policy.\u003c\/li\u003e\n\u003cli\u003eAll items are brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the protective field range of this SICK S3000 scanner?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eS30A-7111DP\u003c\/strong\u003e offers a protective field range of 7 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the warning field range?\u003c\/strong\u003e\u003cbr\u003eA: The warning field range is 49 m (20 m at 20% reflectivity).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the scanning angle?\u003c\/strong\u003e\u003cbr\u003eA: The scanning angle is 190°.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What resolution options does this scanner provide?\u003c\/strong\u003e\u003cbr\u003eA: You can configure 30 mm, 40 mm, 50 mm, 70 mm, or 150 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the response time?\u003c\/strong\u003e\u003cbr\u003eA: The response time is 60 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What safety integrity level does it meet?\u003c\/strong\u003e\u003cbr\u003eA: It meets SIL 2 (IEC 61508) and PL d (EN ISO 13849).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the enclosure rating?\u003c\/strong\u003e\u003cbr\u003eA: It has an IP65 rating (EN 60529).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The ambient operating temperature range is –10 °C to +50 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this scanner have local inputs or outputs?\u003c\/strong\u003e\u003cbr\u003eA: No, it operates only in a network with a corresponding controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What fieldbus does it use?\u003c\/strong\u003e\u003cbr\u003eA: It uses PROFINET PROFIsafe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support 30-day returns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"SICK","offers":[{"title":"Default Title","offer_id":48108200460449,"sku":"S30A-7111DP","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/S30A-7111DP_1.jpg?v=1792143713","url":"https:\/\/www.autonexcontrol.com\/products\/s30a-7111dp-sick-s3000-profinet-safety-laser-scanner-7m-range","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}