{"product_id":"s30a-4111dp-s3000-safety-laser-scanner-sick","title":"S30A-4111DP S3000 Safety Laser Scanner - SICK","description":"\u003ch2\u003e\u003cstrong\u003eS30A-4111DP S3000 Safety Laser Scanner by SICK\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e SICK\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eS30A-4111DP\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e S3000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e 1045651\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective field range:\u003c\/strong\u003e 4 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum warning field range:\u003c\/strong\u003e 49 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistance measuring range:\u003c\/strong\u003e 49 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan angle:\u003c\/strong\u003e 190°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 30 mm, 40 mm, 50 mm, 70 mm, or 150 mm, configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 60 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of field sets:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of fields:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of monitoring cases:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety and Performance Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety integrity level:\u003c\/strong\u003e SIL2 (IEC 61508), SILCL2 (EN 62061)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Category 3 (EN ISO 13849)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerformance level:\u003c\/strong\u003e PL d (EN ISO 13849)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePFHd:\u003c\/strong\u003e 8.0 1E-08 (EN ISO 13849)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMission time:\u003c\/strong\u003e 20 a (EN ISO 13849)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Type 3 (IEC 61496)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of multiple samplings:\u003c\/strong\u003e Configurable 2 to 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLaser class:\u003c\/strong\u003e 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePROFINET and Network Properties\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort properties:\u003c\/strong\u003e Auto-negotiation, auto-crossover (MDIX), auto-polarity, 100Base-TX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice properties:\u003c\/strong\u003e GSDML according to GSDML specification V2.25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET IO device:\u003c\/strong\u003e 2-port real-time switch according to PROFINET specification V2.2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFIsafe profile:\u003c\/strong\u003e 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCycle time:\u003c\/strong\u003e 4, 8, 16, 32 ms, etc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformance:\u003c\/strong\u003e Conformance Class B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTopology support:\u003c\/strong\u003e SNMP, MIB-2, LLDP according to IEEE 802.1AB, MRP client support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch properties:\u003c\/strong\u003e Filtering Data Base according to IEEE 802.1D, 6 prioritization levels for IEEE 802.1Q\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 64 KB SRAM for caching telegrams, managed in 768-byte segments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelegram extension:\u003c\/strong\u003e Based on \"Cut-through\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort status:\u003c\/strong\u003e Disabled, Blocking, Forwarding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData transfer:\u003c\/strong\u003e Support for non-real-time and real-time data transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctions and Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous area protection (vertical):\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous area protection (horizontal):\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess protection (vertical):\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic protective field switching:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated configuration memory:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured data output:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal device monitoring (EDM):\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe SICK device communication via EFI\/SDL:\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpanded measured data output (CMS):\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic learning:\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulticast communication:\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupervisor AR:\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMAC-pause mechanism in full duplex:\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBack-pressure in half duplex:\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroadcast Storm Control:\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics and Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration and diagnostics interface:\u003c\/strong\u003e RS-232\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration and diagnostics using CDS:\u003c\/strong\u003e TCP port 9000 and UDP port 30718, RS-232\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReport system errors:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable diagnostics:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeighborhood alerts:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport for port statistics:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\u0026amp;M support:\u003c\/strong\u003e From I\u0026amp;M0 to I\u0026amp;M4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical connection:\u003c\/strong\u003e Copper conductor (2 female connectors for RJ-45 push-pull plug), system plug with or without connecting cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncremental encoder inputs:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the protective field range of the S30A-4111DP?\u003c\/strong\u003e\u003cbr\u003eA: The protective field range is 4 m, and the maximum warning field range is 49 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many protective fields can this scanner monitor at the same time?\u003c\/strong\u003e\u003cbr\u003eA: It monitors 2 protective fields simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What resolution options does this S3000 model support?\u003c\/strong\u003e\u003cbr\u003eA: You can configure 30 mm, 40 mm, 50 mm, 70 mm, or 150 mm resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the response time of the S30A-4111DP?\u003c\/strong\u003e\u003cbr\u003eA: The response time is 60 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What safety level does this scanner meet?\u003c\/strong\u003e\u003cbr\u003eA: It meets SIL2, SILCL2, Category 3, PL d, and Type 3 requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the ambient operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The ambient operating temperature range is -10 °C to +50 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the enclosure rating?\u003c\/strong\u003e\u003cbr\u003eA: The enclosure rating is IP 65.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many field sets and monitoring cases does it support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 8 field sets, 16 fields, and 16 monitoring cases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What network protocol does this scanner use?\u003c\/strong\u003e\u003cbr\u003eA: It uses PROFINET IO with PROFIsafe profile and 100Base-TX ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the mission time?\u003c\/strong\u003e\u003cbr\u003eA: The mission time is 20 years according to EN ISO 13849.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship by FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support 30-day returns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"SICK","offers":[{"title":"Default Title","offer_id":48065548124321,"sku":"S30A-4111DP","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/S30A-4111DP_1.jpg?v=1791883713","url":"https:\/\/www.autonexcontrol.com\/products\/s30a-4111dp-s3000-safety-laser-scanner-sick","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}