{"product_id":"nu-en8n-keyence-e-con-input-unit-8-input-nu-series-module","title":"NU-EN8N Keyence e-CON Input Unit 8-Input NU Series Module","description":"\u003ch2\u003e\n\u003cstrong\u003eNU-EN8N Keyence e-CON Input Unit – 8-Input Module for NU Series\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Keyence | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eNU-EN8N\u003c\/strong\u003e | \u003cstrong\u003eSeries:\u003c\/strong\u003e NU\u003c\/li\u003e\n\u003cli\u003eEight input channels use e-CON 4-pin connectors for quick wiring\u003c\/li\u003e\n\u003cli\u003eInput type covers NPN open-collector or contact signals\u003c\/li\u003e\n\u003cli\u003eResponse time stays at \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e20 µs or less\u003c\/strong\u003e\u003c\/span\u003e for fast signal capture\u003c\/li\u003e\n\u003cli\u003eInput resistance measures 2.4 kOhm across each channel\u003c\/li\u003e\n\u003cli\u003eMinimum ON voltage reaches 6 V for reliable switching\u003c\/li\u003e\n\u003cli\u003eMaximum OFF current stays at 0.9 mA per input\u003c\/li\u003e\n\u003cli\u003eSupply current stays at 520 mA or less across eight ports\u003c\/li\u003e\n\u003cli\u003eSensor connection supports up to 16 N-bus compatible amplifier units\u003c\/li\u003e\n\u003cli\u003eTotal passing current stays at 1,200 mA or less across connected sensors\u003c\/li\u003e\n\u003cli\u003eSupply voltage covers 12 to 24 VDC ±10% from the connected unit\u003c\/li\u003e\n\u003cli\u003eOperating temperature spans \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-20 to +55 °C\u003c\/strong\u003e\u003c\/span\u003e with no freezing allowed\u003c\/li\u003e\n\u003cli\u003eRelative humidity range covers 35 to 85% RH without condensation\u003c\/li\u003e\n\u003cli\u003eWeight measures approximately 0.055 kg including the tag\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eNU-EN8N\u003c\/strong\u003e beside your NU series communication unit\u003c\/li\u003e\n\u003cli\u003eWire each input through the e-CON 4-pin connectors\u003c\/li\u003e\n\u003cli\u003eUse NPN open-collector or contact signals for each channel\u003c\/li\u003e\n\u003cli\u003eKeep each input voltage above \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e6 V\u003c\/strong\u003e\u003c\/span\u003e for a stable ON state\u003c\/li\u003e\n\u003cli\u003eAttach N-bus sensor amplifiers using the wiring-saving connector\u003c\/li\u003e\n\u003cli\u003eKeep total sensor current below \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e1,200 mA\u003c\/strong\u003e\u003c\/span\u003e to protect the unit\u003c\/li\u003e\n\u003cli\u003eConfirm the 12 to 24 VDC supply comes from the communication unit\u003c\/li\u003e\n\u003cli\u003eCheck ambient temperature stays within \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-20 to +55 °C\u003c\/strong\u003e\u003c\/span\u003e during operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eNU-EN8N\u003c\/strong\u003e e-CON input unit\u003c\/li\u003e\n\u003cli\u003eN-bus wiring-saving connector\u003c\/li\u003e\n\u003cli\u003eQuick installation reference sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship orders via FedEx, UPS, and DHL for global delivery\u003c\/li\u003e\n\u003cli\u003eMost orders leave our warehouse within 5 business days\u003c\/li\u003e\n\u003cli\u003eWe keep this unit in stock for immediate fulfillment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many input channels does this unit provide?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eNU-EN8N\u003c\/strong\u003e provides eight inputs through e-CON 4-pin connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What input type does this unit accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts NPN open-collector or contact signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the response time?\u003c\/strong\u003e\u003cbr\u003eA: Response time stays at \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e20 µs or less\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the input resistance?\u003c\/strong\u003e\u003cbr\u003eA: Each channel has an input resistance of 2.4 kOhm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum ON voltage?\u003c\/strong\u003e\u003cbr\u003eA: The minimum ON voltage reaches 6 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What supply voltage does this unit require?\u003c\/strong\u003e\u003cbr\u003eA: It needs 12 to 24 VDC ±10% from the connected communication unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How much supply current does it draw?\u003c\/strong\u003e\u003cbr\u003eA: Supply current stays at 520 mA or less across eight ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The unit works from \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-20 to +55 °C\u003c\/strong\u003e\u003c\/span\u003e without freezing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the unit in stock and how fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we have it in stock and ship within 5 days via DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We accept returns within 30 days. All units are brand new and original.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How much does the unit weigh?\u003c\/strong\u003e\u003cbr\u003eA: It weighs approximately 0.055 kg including the tag.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Keyence","offers":[{"title":"Default Title","offer_id":48892954837153,"sku":"NU-EN8N","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/NU-EN8N-2.jpg?v=1793951658","url":"https:\/\/www.autonexcontrol.com\/products\/nu-en8n-keyence-e-con-input-unit-8-input-nu-series-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}