{"product_id":"kv-n60dt-keyence-plc-kv-nano-series","title":"KV-N60DT Keyence PLC KV Nano Series","description":"\u003ch2\u003e\u003cstrong\u003eKV-N60DT Keyence KV Nano Series All-in-One PLC\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Keyence\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KV-N60DT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e KV Nano\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgram capacity:\u003c\/strong\u003e 16k steps for ladder and KV Script programs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExecution speed:\u003c\/strong\u003e Basic instructions reach 50 ns minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication speed:\u003c\/strong\u003e Application instructions reach 170 ns minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgram languages:\u003c\/strong\u003e Expanded ladder, KV Script and mnemonic code\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in I\/O:\u003c\/strong\u003e 36 input points and 24 output points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositioning:\u003c\/strong\u003e 3 pulse output axes at up to 100 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-speed counter:\u003c\/strong\u003e 2 points, 32-bit auto-reset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCounter frequency:\u003c\/strong\u003e 100 kHz single phase and 50 kHz phase difference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput type:\u003c\/strong\u003e MOSFET transistor, sink\/NPN wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput rating:\u003c\/strong\u003e 30 VDC, 0.5 A per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 24 VDC nominal, ±10% tolerance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput power supply:\u003c\/strong\u003e 24 VDC, ±10%, 0.6 A capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eExpansion and Communication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe base unit accepts up to 8 expansion units through the backplane.\u003c\/li\u003e\n\u003cli\u003eThe system reaches \u003cspan style=\"color: #0b6e4f;\"\u003e\u003cstrong\u003e256 I\/O points maximum\u003c\/strong\u003e\u003c\/span\u003e excluding the base unit.\u003c\/li\u003e\n\u003cli\u003eA built-in RS-232C modular connector handles serial links.\u003c\/li\u003e\n\u003cli\u003eThe port supports KV STUDIO and no-protocol serial modes.\u003c\/li\u003e\n\u003cli\u003eCommunication modules extend the system through the same backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Physical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature ranges from 0 to +55 °C without freezing.\u003c\/li\u003e\n\u003cli\u003eStorage temperature ranges from -25 to +75 °C.\u003c\/li\u003e\n\u003cli\u003eRelative humidity stays between 5 and 95% RH without condensation.\u003c\/li\u003e\n\u003cli\u003eThe unit weighs approximately 0.75 kg.\u003c\/li\u003e\n\u003cli\u003eKeyence does not publish a protection rating or exact dimensions for this model.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the base unit on a flat panel with clear ventilation space.\u003c\/li\u003e\n\u003cli\u003eConnect a stable 24 VDC supply within the ±10% tolerance window.\u003c\/li\u003e\n\u003cli\u003eWire inputs and outputs to the terminal block according to the sink\/NPN scheme.\u003c\/li\u003e\n\u003cli\u003eKeep output loads below \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e0.5 A per point\u003c\/strong\u003e\u003c\/span\u003e to protect the MOSFET circuits.\u003c\/li\u003e\n\u003cli\u003eAttach expansion units to the backplane before powering the system.\u003c\/li\u003e\n\u003cli\u003eRoute pulse output and counter cables away from high-current lines.\u003c\/li\u003e\n\u003cli\u003eConfigure programs and parameters through KV STUDIO over RS-232C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Keyence \u003cstrong\u003eKV-N60DT\u003c\/strong\u003e PLC base unit\u003c\/li\u003e\n\u003cli\u003e1 × Terminal block connector set\u003c\/li\u003e\n\u003cli\u003e1 × RS-232C modular connector cover\u003c\/li\u003e\n\u003cli\u003e1 × Quick start documentation set\u003c\/li\u003e\n\u003cli\u003eProtective packaging for safe transport\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship orders within 5 days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003eFedEx, UPS and DHL handle delivery worldwide.\u003c\/li\u003e\n\u003cli\u003eTracking numbers go to your email once the parcel leaves our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the KV-N60DT new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply new original units only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you keep stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we hold ready stock for this model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We dispatch within 5 days using DHL, FedEx or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we accept returns within 30 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many I\/O points does the base unit offer?\u003c\/strong\u003e\u003cbr\u003eA: The base unit provides 36 inputs and 24 outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many expansion units can I connect?\u003c\/strong\u003e\u003cbr\u003eA: You can connect up to 8 expansion units for 256 total points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What positioning speed does the PLC support?\u003c\/strong\u003e\u003cbr\u003eA: It drives 3 axes at up to 100 kHz pulse output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What counter frequency can I expect?\u003c\/strong\u003e\u003cbr\u003eA: The counters reach 100 kHz single phase and 50 kHz phase difference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What supply voltage does the unit need?\u003c\/strong\u003e\u003cbr\u003eA: It runs on 24 VDC with ±10% tolerance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which serial port does it include?\u003c\/strong\u003e\u003cbr\u003eA: It includes one RS-232C modular connector for KV STUDIO and no-protocol links.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Keyence","offers":[{"title":"Default Title","offer_id":48961309835425,"sku":"KV-N60DT","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/KV-N60DT.jpg?v=1794383601","url":"https:\/\/www.autonexcontrol.com\/products\/kv-n60dt-keyence-plc-kv-nano-series","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}