{"product_id":"iv-g15-keyence-sensor-amplifier-expansion-unit","title":"IV-G15 Keyence Sensor Amplifier Expansion Unit","description":"\u003ch2\u003e\u003cstrong\u003eIV-G15 Keyence Sensor Amplifier Expansion Unit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Keyence\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIV-G15\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e IV-G Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Sensor amplifier, expansion unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTools:\u003c\/strong\u003e Controlled via the connected \u003cstrong\u003eIV-G10\u003c\/strong\u003e main unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in ports:\u003c\/strong\u003e Provided through the connected \u003cstrong\u003eIV-G10\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e FTP client, EtherNet\/IP, PROFINET via the \u003cstrong\u003eIV-G10\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication expansion:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eSupplied from the IV-G10 main unit\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e Not available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput type:\u003c\/strong\u003e Open collector output via main unit, \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e20 mA when linked to IV-G15\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e0 to +50°C, no freezing\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 35 to 85% RH, no condensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection rating:\u003c\/strong\u003e Not available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Not available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Not available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower off the \u003cstrong\u003eIV-G10\u003c\/strong\u003e main unit before you attach the expansion module.\u003c\/li\u003e\n\u003cli\u003eConnect the \u003cstrong\u003eIV-G15\u003c\/strong\u003e to the main unit using the dedicated link connector.\u003c\/li\u003e\n\u003cli\u003eMount both units on a DIN rail or flat panel inside the control cabinet.\u003c\/li\u003e\n\u003cli\u003eKeep the assembly away from heat sources to hold the 0 to +50°C range.\u003c\/li\u003e\n\u003cli\u003eCheck that the main unit supplies power correctly after you link the module.\u003c\/li\u003e\n\u003cli\u003eConfirm output wiring and the 20 mA link current before you start production.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Keyence \u003cstrong\u003eIV-G15\u003c\/strong\u003e sensor amplifier expansion unit\u003c\/li\u003e\n\u003cli\u003e1x Instruction manual\u003c\/li\u003e\n\u003cli\u003e1x Link connector for the \u003cstrong\u003eIV-G10\u003c\/strong\u003e main unit\u003c\/li\u003e\n\u003cli\u003e1x DIN rail mounting bracket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship orders through FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eWe dispatch in-stock items within 5 business days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between the IV-G15 and the IV-G10?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eIV-G15\u003c\/strong\u003e is an expansion unit. The \u003cstrong\u003eIV-G10\u003c\/strong\u003e is the main amplifier that powers and controls it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the IV-G15 need its own power supply?\u003c\/strong\u003e\u003cbr\u003eA: No, the \u003cstrong\u003eIV-G10\u003c\/strong\u003e main unit supplies all power to the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can the IV-G15 work without an IV-G10?\u003c\/strong\u003e\u003cbr\u003eA: No, this module requires a connected \u003cstrong\u003eIV-G10\u003c\/strong\u003e main unit to operate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the link current when connected to the IV-G15?\u003c\/strong\u003e\u003cbr\u003eA: The open collector output runs at 20 mA when linked to the \u003cstrong\u003eIV-G15\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which protocols does the IV-G15 support?\u003c\/strong\u003e\u003cbr\u003eA: It uses FTP client, EtherNet\/IP, and PROFINET through the connected \u003cstrong\u003eIV-G10\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The unit operates from 0 to +50°C with no freezing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the IV-G15 still in production?\u003c\/strong\u003e\u003cbr\u003eA: No, Keyence marks this model as discontinued and recommends a replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We accept returns within 30 days. All units are brand new and original.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We keep stock on hand and ship within 5 days using DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Keyence","offers":[{"title":"Default Title","offer_id":49056979681441,"sku":"IV-G15","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IV-G15.jpg?v=1794901563","url":"https:\/\/www.autonexcontrol.com\/products\/iv-g15-keyence-sensor-amplifier-expansion-unit","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}