{"product_id":"is400tcash1afd-ge-mark-vie-core-analog-i-o-terminal-board","title":"IS400TCASH1AFD GE Mark VIe Core Analog I\/O Terminal Board","description":"\u003ch2\u003e\u003cstrong\u003eIS400TCASH1AFD Core Analog I\/O Terminal Board – GE Energy Mark VIe Series\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003eGE Energy\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIS400TCASH1AFD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003eMark VIe\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Core Analog I\/O Terminal Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Core Analog (PCAA) Module Terminal Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Status:\u003c\/strong\u003e Mark VIe Terminal PCB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelated Mark VIe Offerings:\u003c\/strong\u003e IS230PCAAH1A, IS230PCAAH1B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Simplex applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation Hardware:\u003c\/strong\u003e Not Related\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Rarity:\u003c\/strong\u003e Rare\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-30 to +65°C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location Rating:\u003c\/strong\u003e Class 1, Division 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Routing:\u003c\/strong\u003e The board provides terminals and signal routing into the BCAA and BCAB processing boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e It accepts bulk 28 V control power using the P5 connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e The board provides power through the P4 connector to a JGPA board in the input cable shield termination location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTCAT Compatibility:\u003c\/strong\u003e The \u003cstrong\u003eIS400TCASH1AFD\u003c\/strong\u003e works with the TCAT board and provides the P1 and P2 68-pin connectors for TCAT terminal board cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e It connects with the PCAA I\/O pack but does not include a DIN-rail mount.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e The board is designed for simplex redundancy applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features and Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations:\u003c\/strong\u003e The CPUs, network switches, and I\/O components are authorized for Class 1, Division 2 locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e The Mark VIe platform functions without fans or external cooling from \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-30 to +65°C\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e These features help reduce downtime in demanding industrial operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Capabilities:\u003c\/strong\u003e The Mark VIe turbine control system includes Ethernet communication for direct sensor and actuator interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect I\/O Interface:\u003c\/strong\u003e The design communicates directly with turbine sensors and actuators and removes the need for interposing instrumentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProven Reliability:\u003c\/strong\u003e Mark series controllers have earned a strong reputation for outstanding running reliability in power generation and infrastructure systems worldwide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the terminal board in its designated panel position. DIN rail hardware does not apply to this board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect bulk 28 V control power to the P5 connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJGPA Connection:\u003c\/strong\u003e Route power through the P4 connector to the JGPA board at the input cable shield termination location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTCAT Cable Connection:\u003c\/strong\u003e Use the P1 and P2 68-pin connectors for the TCAT terminal board cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCAA Connection:\u003c\/strong\u003e Confirm proper connection between the terminal board and the PCAA I\/O pack before power up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Termination:\u003c\/strong\u003e Verify that the input cable shield termination point is properly grounded.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinal Check:\u003c\/strong\u003e Inspect all connections and verify signal routing into the BCAA and BCAB processing boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWiring Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eP5 Connector:\u003c\/strong\u003e Accepts bulk 28 V control power for the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP4 Connector:\u003c\/strong\u003e Provides power to a JGPA board at the input cable shield termination location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP1 and P2 Connectors:\u003c\/strong\u003e 68-pin connectors for TCAT terminal board cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBCAA and BCAB Boards:\u003c\/strong\u003e Receive routed signals from the terminal board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance and Environmental Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e The board supports Core Analog PCAA signal routing for gas turbine control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e It supports the Mark VIe Ethernet-based distributed control architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e The terminal board routes low-level analog signals from turbine sensors and actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e Signal routing remains consistent across the specified operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e The board supports PCAA analog I\/O resolution for control and measurement tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e It operates reliably from \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-30 to +65°C\u003c\/strong\u003e\u003c\/span\u003e without fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e The platform suits harsh industrial environments and holds Class 1, Division 2 approval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-Interference Ability:\u003c\/strong\u003e Proper shield termination and cable routing reduce signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eIS400TCASH1AFD\u003c\/strong\u003e Core Analog I\/O Terminal Board\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static protective wrapping\u003c\/li\u003e\n\u003cli\u003e1 x Protective shipping packaging\u003c\/li\u003e\n\u003cli\u003e1 x Order documentation package without certificate information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe keep this item in stock and dispatch it within 5 days after order confirmation.\u003c\/li\u003e\n\u003cli\u003eWe ship by common express methods such as FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eWe support 30-day returns under our stated return policy.\u003c\/li\u003e\n\u003cli\u003eAll items are brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the model number of this GE terminal board?\u003c\/strong\u003e\u003cbr\u003eA: The model number is \u003cstrong\u003eIS400TCASH1AFD\u003c\/strong\u003e, and it belongs to the Mark VIe series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does this terminal board do?\u003c\/strong\u003e\u003cbr\u003eA: It provides terminals and signal routing into the BCAA and BCAB processing boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which I\/O pack does this board connect with?\u003c\/strong\u003e\u003cbr\u003eA: It connects with the PCAA I\/O pack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What related Mark VIe offerings work with this board?\u003c\/strong\u003e\u003cbr\u003eA: Related offerings include IS230PCAAH1A and IS230PCAAH1B.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this board include a DIN-rail mount?\u003c\/strong\u003e\u003cbr\u003eA: No, DIN rail installation hardware does not apply to this board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What redundancy applications does it support?\u003c\/strong\u003e\u003cbr\u003eA: The board is designed for simplex redundancy applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How does the board receive power?\u003c\/strong\u003e\u003cbr\u003eA: It accepts bulk 28 V control power using the P5 connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How does the board connect to the TCAT?\u003c\/strong\u003e\u003cbr\u003eA: It provides the P1 and P2 68-pin connectors for TCAT terminal board cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The platform operates from \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-30 to +65°C\u003c\/strong\u003e\u003c\/span\u003e without fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this board approved for hazardous locations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the CPUs, network switches, and I\/O components are authorized for Class 1, Division 2 locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this item in stock, and how fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep it in stock and ship within 5 days using FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47899565850785,"sku":"IS400TCASH1AFD","price":203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IS400TCASH1AFD.jpg?v=1789978632","url":"https:\/\/www.autonexcontrol.com\/products\/is400tcash1afd-ge-mark-vie-core-analog-i-o-terminal-board","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}