{"product_id":"is230sdiih1a-ge-mark-vie-contact-input-module-16-channel","title":"IS230SDIIH1A GE Mark VIe Contact Input Module 16-Channel","description":"\u003ch2\u003e\u003cstrong\u003eIS230SDIIH1A Simplex Contact Input Module from GE Energy\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIS230SDIIH1A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Simplex Contact Input with Point Isolation Terminal Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark VIe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 16 contact voltage input channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 14 to 32 V dc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Voltage Levels:\u003c\/strong\u003e 48 V dc, 125 V dc, 115 V ac rms, and 230 V ac rms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Lead Resistance:\u003c\/strong\u003e 15 Ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 24 V dc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN-rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnology:\u003c\/strong\u003e Surface mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Protection:\u003c\/strong\u003e Spray-based conformal coat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30 to 65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 15.9 cm high x 17.8 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 lbs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual:\u003c\/strong\u003e GEH-6721L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e In stock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module provides 16 point-isolated voltage detection circuits for contact sensing.\u003c\/li\u003e\n\u003cli\u003eIt senses voltages across relay contacts, fuses, switches, and other contact types.\u003c\/li\u003e\n\u003cli\u003eIt uses an IS200SDII terminal board plus a PDII I\/O pack.\u003c\/li\u003e\n\u003cli\u003eEach channel accepts 48 V dc, 125 V dc, 115 V ac rms, or 230 V ac rms.\u003c\/li\u003e\n\u003cli\u003eThree terminals exist for each contact input channel.\u003c\/li\u003e\n\u003cli\u003ePluggable Euro-style box-type terminal blocks simplify field wiring.\u003c\/li\u003e\n\u003cli\u003eA connector accepts different WDII option boards for system wetting.\u003c\/li\u003e\n\u003cli\u003eAll 16 channels stay point-isolated when you use PDII with SDII only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperation Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe sensing circuit converts voltage at the TB input into an isolated digital signal.\u003c\/li\u003e\n\u003cli\u003eFirmware calculates the voltage present at the TB input.\u003c\/li\u003e\n\u003cli\u003eIt declares the contact status as on or off based on voltage presence.\u003c\/li\u003e\n\u003cli\u003eEach input stays isolated from the others for reliable signal separation.\u003c\/li\u003e\n\u003cli\u003eAll inputs are point-isolated and system-isolated without an option board.\u003c\/li\u003e\n\u003cli\u003eWith WDIIH1, channels support system wetting at 24 V dc or AC rms levels.\u003c\/li\u003e\n\u003cli\u003eAC frequency range for 50 Hz and 60 Hz is ±3 Hz.\u003c\/li\u003e\n\u003cli\u003eRemoving the channel fuse allows use as a point-isolated signal path.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWDII Option Board Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWDIIH1:\u003c\/strong\u003e Supports system wetting with 24 V dc, 115 V ac rms, or 230 V ac rms across all 16 channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWDIIH2:\u003c\/strong\u003e Supports system wetting with 48 V dc across all 16 channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWDIIH3:\u003c\/strong\u003e Supports system wetting with 125 V dc only; all channels are group-isolated.\u003c\/li\u003e\n\u003cli\u003eEach channel can be individually configured as point-isolated on WDIIH1 and WDIIH2.\u003c\/li\u003e\n\u003cli\u003eA mix of point isolation and group isolation is possible on WDIIH1 and WDIIH2.\u003c\/li\u003e\n\u003cli\u003eWDII boards include an isolated voltage detector circuit to monitor wetting voltage.\u003c\/li\u003e\n\u003cli\u003eWDIIH boards offer field line fault monitoring with one or two field resistors.\u003c\/li\u003e\n\u003cli\u003ePDII can detect open field wiring or an open fuse on WDII with a parallel resistor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGroup Isolated Input Signals\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContact input channels receive wetting voltage through a WDII option board.\u003c\/li\u003e\n\u003cli\u003eWDIIH1A provides 115 V\/240 V ac rms, 50\/60 Hz, and 24 V dc wetting voltage.\u003c\/li\u003e\n\u003cli\u003eIndividual fuses exist in each supply line for protection.\u003c\/li\u003e\n\u003cli\u003eWetting voltage connects through JE1 or JE2 parallel connectors.\u003c\/li\u003e\n\u003cli\u003eConnect pin 1 of JE1 to the positive and pin 3 to the negative.\u003c\/li\u003e\n\u003cli\u003eDo not reverse polarity at JE1 or JE2.\u003c\/li\u003e\n\u003cli\u003eGroup isolation replaces point isolation when a WDII board connects.\u003c\/li\u003e\n\u003cli\u003eThe system wetting voltage then comes through the WDII board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eIS230SDIIH1A\u003c\/strong\u003e on a standard DIN rail.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring to the pluggable Euro-style box-type terminal blocks.\u003c\/li\u003e\n\u003cli\u003eUse three terminals per contact input channel for proper wiring.\u003c\/li\u003e\n\u003cli\u003eAttach the PDII I\/O pack to the IS200SDII terminal board.\u003c\/li\u003e\n\u003cli\u003eAdd a WDII option board when system wetting is required.\u003c\/li\u003e\n\u003cli\u003eVerify the channel fuse is present before enabling system wetting.\u003c\/li\u003e\n\u003cli\u003eCheck the JE1 or JE2 polarity before applying wetting voltage.\u003c\/li\u003e\n\u003cli\u003eConfirm the operating temperature stays within -30 to 65°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eIS230SDIIH1A\u003c\/strong\u003e Simplex Contact Input Module\u003c\/li\u003e\n\u003cli\u003eOne IS200SDII terminal board\u003c\/li\u003e\n\u003cli\u003eOne PDII I\/O pack\u003c\/li\u003e\n\u003cli\u003eAnti-static protective packaging\u003c\/li\u003e\n\u003cli\u003eProtective foam or cushioning material\u003c\/li\u003e\n\u003cli\u003eOuter shipping carton\u003c\/li\u003e\n\u003cli\u003eProduct label with model and series information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe keep this item in stock and ship it within 5 days.\u003c\/li\u003e\n\u003cli\u003eWe use common express methods such as FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eWe support returns within 30 days.\u003c\/li\u003e\n\u003cli\u003eThis item is brand new and original.\u003c\/li\u003e\n\u003cli\u003eContact us for technical questions or order support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the \u003cstrong\u003eIS230SDIIH1A\u003c\/strong\u003e used for?\u003c\/strong\u003e\u003cbr\u003eA: It senses voltages across relay contacts, switches, fuses, and other contacts in Mark VIe systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many channels does it provide?\u003c\/strong\u003e\u003cbr\u003eA: It provides 16 contact voltage input channels with point isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What voltage range does the module support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 14 to 32 V dc with channel levels of 48 V dc, 125 V dc, 115 V ac rms, and 230 V ac rms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum lead resistance?\u003c\/strong\u003e\u003cbr\u003eA: The maximum lead resistance is 15 Ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The operating temperature range is -30 to 65°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How does the module mount?\u003c\/strong\u003e\u003cbr\u003eA: It mounts on a DIN rail using surface mount technology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which option boards work with this module?\u003c\/strong\u003e\u003cbr\u003eA: The WDIIH1, WDIIH2, and WDIIH3 option boards work with the SDII system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I mix point isolation and group isolation?\u003c\/strong\u003e\u003cbr\u003eA: Yes, WDIIH1 and WDIIH2 allow a mix of point isolation and group isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the product condition?\u003c\/strong\u003e\u003cbr\u003eA: The product is brand new and original.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days after order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which shipping methods do you use?\u003c\/strong\u003e\u003cbr\u003eA: We use common express methods such as FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support returns within 30 days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone \/ WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47174366199969,"sku":"IS230SDIIH1A","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IS230SDIIH1A.jpg?v=1789110436","url":"https:\/\/www.autonexcontrol.com\/products\/is230sdiih1a-ge-mark-vie-contact-input-module-16-channel","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}