{"product_id":"is230pcaah1a-ge-mark-vie-core-analog-module","title":"IS230PCAAH1A GE Mark VIe Core Analog Module","description":"\u003ch2\u003e\u003cstrong\u003eIS230PCAAH1A Core Analog Module – GE Energy Mark VIe Series\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003eGE Energy\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIS230PCAAH1A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003eMark VIe\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Core Analog Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Core Analog Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Board:\u003c\/strong\u003e TCAS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Terminal Board:\u003c\/strong\u003e TCAT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Input and Output Signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 17.71 × 13.77 × 7.87 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-30 to +65°C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Strategy:\u003c\/strong\u003e Non DIN-Rail Modular\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation Hardware:\u003c\/strong\u003e Not Included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Manufacture:\u003c\/strong\u003e United States (USA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSupported I\/O Types\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermocouple inputs for high-temperature measurement\u003c\/li\u003e\n\u003cli\u003eAnalog 4-20 mA current loop inputs and outputs\u003c\/li\u003e\n\u003cli\u003eSeismic inputs for vibration monitoring\u003c\/li\u003e\n\u003cli\u003eLVDT excitation and inputs for position sensing\u003c\/li\u003e\n\u003cli\u003ePulse rate inputs for speed and frequency measurement\u003c\/li\u003e\n\u003cli\u003eServo coil driver outputs for actuator control\u003c\/li\u003e\n\u003cli\u003e+\/- 12 V power output for compatible field devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Modes:\u003c\/strong\u003e The module supports simplex, dual, and TMR (Triple Modular Redundant) configurations. A single TCAT terminal board distributes signal inputs to one, two, or three PCAA modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower and Grounding Extensions:\u003c\/strong\u003e An adjacent JGPA board's shield ground and 24 V field power terminals supplement the terminals on the PCAA and TCAT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Board Architecture:\u003c\/strong\u003e The module includes a BPPB processor board, two application I\/O boards, and a TCAS terminal board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eServiceability:\u003c\/strong\u003e The entire module is the least replaceable unit (LRU). No support is provided to diagnose or replace individual internal boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e The module uses a 28 V dc power connector, two RJ45 Ethernet connectors, and 120 Euro-style box terminals for field device I\/O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower to JGPA:\u003c\/strong\u003e Power reaches a JGPA board through connector P4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTCAT Connection:\u003c\/strong\u003e Two 68-pin cables on connectors P1 and P2 connect the module to the TCAT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Routing:\u003c\/strong\u003e PCAA signals divide into two groups. The TCAT routes signal inputs that can fan from a single input into a single, dual, or TMR PCAA module. Signals dedicated to one PCAA module wire directly to terminals. PCAA can operate without TCAT when fanned inputs are not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProcessor Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo fully independent 10\/100 Ethernet ports with connectors\u003c\/li\u003e\n\u003cli\u003eHardware watchdog timer and reset circuit\u003c\/li\u003e\n\u003cli\u003eInternal temperature sensor for thermal monitoring\u003c\/li\u003e\n\u003cli\u003eStatus-indicating LEDs for quick diagnostics\u003c\/li\u003e\n\u003cli\u003eElectronic ID and the ability to read IDs on other boards\u003c\/li\u003e\n\u003cli\u003eSoft start and current limiter on the input power connector\u003c\/li\u003e\n\u003cli\u003eLocal power supplies with sequencing and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Control:\u003c\/strong\u003e The 28 V input circuit includes power management. A soft start function controls current inrush during power application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisturbance Prevention:\u003c\/strong\u003e After power application, a fast current limit function prevents a power disturbance from propagating back onto the 28 V power system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePWR Indicator:\u003c\/strong\u003e The green PWR indicator illuminates when power is present and functioning properly. If the current limit function is enabled, the indicator stays illuminated until the problem is resolved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the model number of this GE Energy module?\u003c\/strong\u003e\u003cbr\u003eA: The model number is \u003cstrong\u003eIS230PCAAH1A\u003c\/strong\u003e, and it belongs to the Mark VIe series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does this module do in a Mark VIe system?\u003c\/strong\u003e\u003cbr\u003eA: It provides a large portion of the analog signal I\/O required to operate a gas turbine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What I\/O types does the module support?\u003c\/strong\u003e\u003cbr\u003eA: It supports thermocouples, 4-20 mA current loops, seismic inputs, LVDT excitation and inputs, pulse rate inputs, and servo coil outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which system modes can use this module?\u003c\/strong\u003e\u003cbr\u003eA: The module supports simplex, dual, and TMR (Triple Modular Redundant) system configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The module operates from \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-30 to +65°C\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What terminal board does this module use?\u003c\/strong\u003e\u003cbr\u003eA: It uses a TCAS terminal board and supports optional TCAT terminal boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many terminals does the PCAA module have?\u003c\/strong\u003e\u003cbr\u003eA: The module features 120 Euro-style pluggable box terminals for field device I\/O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How does the module connect to the TCAT board?\u003c\/strong\u003e\u003cbr\u003eA: Two 68-pin cables on connectors P1 and P2 connect the module to the TCAT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does the green PWR indicator mean?\u003c\/strong\u003e\u003cbr\u003eA: The green PWR indicator illuminates when power is present and functioning properly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What are the dimensions of this module?\u003c\/strong\u003e\u003cbr\u003eA: The module measures 17.71 × 13.77 × 7.87 cm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is DIN rail installation hardware included?\u003c\/strong\u003e\u003cbr\u003eA: No, DIN rail installation hardware is not included with this module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this item in stock, and how fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep it in stock and ship within 5 days using FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47899538292897,"sku":"IS230PCAAH1A","price":203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IS230PCAAH1A-1.jpg?v=1789978312","url":"https:\/\/www.autonexcontrol.com\/products\/is230pcaah1a-ge-mark-vie-core-analog-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}