{"product_id":"is200tbtch1b-ge-mark-vi-thermocouple-terminal-board","title":"IS200TBTCH1B GE Mark VI Thermocouple Terminal Board","description":"\u003ch2\u003e\n\u003cstrong\u003eIS200TBTCH1B Thermocouple Terminal Board – GE Mark VI Speedtronic\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: \u003cstrong\u003eGeneral Electric\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003eIS200TBTCH1B\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct Type: Thermocouple Input Terminal Board\u003c\/li\u003e\n\u003cli\u003eNumber of Channels: \u003cspan style=\"color: #0b6e99;\"\u003e\u003cstrong\u003e24 channels\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermocouple Types: E, J, K, S, T\u003c\/li\u003e\n\u003cli\u003eAdditional Types: B, N, R with PTCCH2 in Mark VIe systems\u003c\/li\u003e\n\u003cli\u003eSpan: \u003cspan style=\"color: #0b6e99;\"\u003e\u003cstrong\u003e-8 mV to +45 mV\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: \u003cspan style=\"color: #0b6e99;\"\u003e\u003cstrong\u003e0 to +45°C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSize: 15.9 cm high x 17.8 cm\u003c\/li\u003e\n\u003cli\u003eAvailability: In Stock\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: United States\u003c\/li\u003e\n\u003cli\u003eNoise Suppression: High-frequency noise suppression\u003c\/li\u003e\n\u003cli\u003eReference: Two cold junction reference devices\u003c\/li\u003e\n\u003cli\u003eSignal Processing: Analog-to-digital conversion and linearization by I\/O processor\u003c\/li\u003e\n\u003cli\u003eInput Distance: Up to 300 meters (984 feet) from turbine control panel\u003c\/li\u003e\n\u003cli\u003eMaximum Two-Way Cable Resistance: \u003cspan style=\"color: #0b6e99;\"\u003e\u003cstrong\u003e450 Ω\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIS200TBTCH1B\u003c\/strong\u003e serves Mark VI and Mark VIe turbine control systems.\u003c\/li\u003e\n\u003cli\u003eIt natively accepts 24 type E, J, K, S, or T thermocouple inputs.\u003c\/li\u003e\n\u003cli\u003eIt supports additional B, N, and R types only with PTCCH2 in Mark VIe systems.\u003c\/li\u003e\n\u003cli\u003eThermocouple inputs connect to two barrier-type terminal blocks.\u003c\/li\u003e\n\u003cli\u003eThe board communicates with the I\/O processor through DC-type connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTBTCH1C\u003c\/strong\u003e suits simplex applications and uses two DC-type connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTBTCH1B\u003c\/strong\u003e suits TMR applications and uses six DC-type connectors.\u003c\/li\u003e\n\u003cli\u003eIn Mark VI systems, TBTC works with the VTCC processor.\u003c\/li\u003e\n\u003cli\u003eA single TBTCH1C connects to one VTCC using two cables.\u003c\/li\u003e\n\u003cli\u003eA TBTCH1B connects to three VTCC boards using six cables.\u003c\/li\u003e\n\u003cli\u003eMark VI systems handle 24 inputs, while Mark VIe systems handle 12 inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect thermocouple wires directly to the two I\/O terminal blocks.\u003c\/li\u003e\n\u003cli\u003eThese removable blocks mount on the terminal board and secure with two screws.\u003c\/li\u003e\n\u003cli\u003eEach block contains 24 terminals that accept up to #12 AWG wires.\u003c\/li\u003e\n\u003cli\u003eA shield terminal strip connects to chassis ground on the left side of each block.\u003c\/li\u003e\n\u003cli\u003eFor Mark VI systems, cable the TBTC J-type connectors to I\/O processors in the VME rack.\u003c\/li\u003e\n\u003cli\u003eKeep thermocouple inputs within 300 meters of the turbine control panel.\u003c\/li\u003e\n\u003cli\u003eMaintain two-way cable resistance below 450 Ω for reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperation Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 24 thermocouple inputs can be grounded or ungrounded.\u003c\/li\u003e\n\u003cli\u003eThe board provides high-frequency noise suppression for stable readings.\u003c\/li\u003e\n\u003cli\u003eTwo cold junction reference devices support accurate temperature measurement.\u003c\/li\u003e\n\u003cli\u003eThe I\/O processor manages analog-to-digital conversion and linearization.\u003c\/li\u003e\n\u003cli\u003eMark VI simplex systems use TBTCH1C with one VTCC processor.\u003c\/li\u003e\n\u003cli\u003eMark VIe simplex systems use two PTCC packs plugged into the TBTC.\u003c\/li\u003e\n\u003cli\u003eTMR systems use TBTCH1B, where thermocouple signals fan out to three J-connectors.\u003c\/li\u003e\n\u003cli\u003eThe TBTC board supports all thermocouple spans documented for its I\/O processor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eIS200TBTCH1B\u003c\/strong\u003e Thermocouple Terminal Board\u003c\/li\u003e\n\u003cli\u003e2 x Removable I\/O terminal blocks\u003c\/li\u003e\n\u003cli\u003e2 x Mounting screws for each terminal block\u003c\/li\u003e\n\u003cli\u003e1 x Shield terminal strip attached to chassis ground\u003c\/li\u003e\n\u003cli\u003eShipping methods: FedEx, UPS, DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the condition of the IS200TBTCH1B?\u003c\/strong\u003e\u003cbr\u003eA: We provide brand new original products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have the IS200TBTCH1B in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep it in stock for immediate order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship the IS200TBTCH1B?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days after order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which logistics carriers do you use?\u003c\/strong\u003e\u003cbr\u003eA: We use common carriers such as DHL, FedEx, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the IS200TBTCH1B?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support returns within 30 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many thermocouple channels does the IS200TBTCH1B support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 24 thermocouple input channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which thermocouple types can the IS200TBTCH1B accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts E, J, K, S, and T types natively.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the input span of the IS200TBTCH1B?\u003c\/strong\u003e\u003cbr\u003eA: The span is -8 mV to +45 mV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The operating temperature range is 0 to +45°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How far can thermocouples be from the control panel?\u003c\/strong\u003e\u003cbr\u003eA: They can be up to 300 meters away.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum two-way cable resistance?\u003c\/strong\u003e\u003cbr\u003eA: The maximum allowable two-way cable resistance is 450 Ω.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the IS200TBTCH1B support TMR applications?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports TMR applications with six DC-type connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which processor works with the TBTC in Mark VI systems?\u003c\/strong\u003e\u003cbr\u003eA: The VTCC processor works with the TBTC in Mark VI systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhone \/ WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47390222516385,"sku":"IS200TBTCH1B","price":254.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IS200TBTCH1B.jpg?v=1789453981","url":"https:\/\/www.autonexcontrol.com\/products\/is200tbtch1b-ge-mark-vi-thermocouple-terminal-board","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}