{"product_id":"innpm01-abb-network-processing-module-infi-net-controlway","title":"INNPM01 ABB Network Processing Module INFI-NET Controlway","description":"\u003ch2\u003e\u003cstrong\u003eINNPM01 ABB Network Processing Module – INFI-NET to Controlway Translator\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eINNPM01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Network Processing Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 256 kbytes ROM and 512 kbytes RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e +5 VDC at 2 A; 10 W nominal, 10 W max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Rates:\u003c\/strong\u003e \u003cspan style=\"color: #0b6e99;\"\u003e\u003cstrong\u003e1 Mbaud (Controlway)\u003c\/strong\u003e\u003c\/span\u003e and \u003cspan style=\"color: #0b6e99;\"\u003e\u003cstrong\u003e83.3 kbaud (module bus)\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Occupies one slot in a standard INFI 90 module mounting unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.45 Kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e P1 edge connector with 12 pins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eException Report Polling\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe NPM module polls control modules within the process control unit for exception reports.\u003c\/li\u003e\n\u003cli\u003eControl modules generate an exception report when a designated point changes by a significant amount.\u003c\/li\u003e\n\u003cli\u003eControl modules generate an exception report when the maximum time expires.\u003c\/li\u003e\n\u003cli\u003eControl modules generate an exception report when an alarm condition changes.\u003c\/li\u003e\n\u003cli\u003eThe poll rate comes from a dipswitch setting on the NPM circuit board.\u003c\/li\u003e\n\u003cli\u003eYou can select poll rates of one, two, four, or eight polls per second.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus LED and Controls\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus LED:\u003c\/strong\u003e Shows module power and operating state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStop\/Reset Pushbutton:\u003c\/strong\u003e Lets you stop or reset the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEight CPU LEDs:\u003c\/strong\u003e Display an error code when the status LED turns red.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff:\u003c\/strong\u003e No power reaches the NPM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid Green:\u003c\/strong\u003e The NPM is in execute mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid Red:\u003c\/strong\u003e The NPM diagnostics detect a hardware failure or configuration problem.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eP1 Edge Connector Pin Assignments\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 1:\u003c\/strong\u003e +5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 2:\u003c\/strong\u003e +5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 3:\u003c\/strong\u003e Power Supply Status\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 4:\u003c\/strong\u003e Controlway B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 5:\u003c\/strong\u003e Common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 6:\u003c\/strong\u003e Common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 7:\u003c\/strong\u003e Unused\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 8:\u003c\/strong\u003e Unused\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 9:\u003c\/strong\u003e Power Fail Interrupt\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 10:\u003c\/strong\u003e Unused\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 11:\u003c\/strong\u003e Controlway A \/ Module Bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 12:\u003c\/strong\u003e Unused\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eINNPM01\u003c\/strong\u003e in one slot of a standard INFI 90 module mounting unit.\u003c\/li\u003e\n\u003cli\u003eConfirm the +5 VDC power supply meets the 2 A and 10 W requirement.\u003c\/li\u003e\n\u003cli\u003eSet the dipswitch on the NPM circuit board to choose the poll rate.\u003c\/li\u003e\n\u003cli\u003eConnect the P1 edge connector to the backplane for power and communication.\u003c\/li\u003e\n\u003cli\u003eCheck the status LED after power-up to confirm green execute mode.\u003c\/li\u003e\n\u003cli\u003eReview the CPU LEDs if the status LED shows red for a fault code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB \u003cstrong\u003eINNPM01\u003c\/strong\u003e Network Processing Module\u003c\/li\u003e\n\u003cli\u003e1 x Protective shipping carton\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static bag\u003c\/li\u003e\n\u003cli\u003e1 x Quick reference packing slip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock:\u003c\/strong\u003e We keep this item in stock for fast order handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e We ship within 5 days after we confirm your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCouriers:\u003c\/strong\u003e We use FedEx, UPS, and DHL for global delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReturns:\u003c\/strong\u003e You can return the item within 30 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e The product is brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What communication rates does the ABB INNPM01 support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 1 Mbaud on the Controlway and 83.3 kbaud on the module bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How much memory does the INNPM01 module have?\u003c\/strong\u003e\u003cbr\u003eA: It carries 256 kbytes ROM and 512 kbytes RAM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What power does the INNPM01 need?\u003c\/strong\u003e\u003cbr\u003eA: It needs +5 VDC at 2 A, with 10 W nominal and 10 W maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does the INNPM01 do in the INFI 90 system?\u003c\/strong\u003e\u003cbr\u003eA: It translates between the INFI-NET loop and the Controlway and routes exception reports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many poll rates can I select on the NPM?\u003c\/strong\u003e\u003cbr\u003eA: You can choose one, two, four, or eight polls per second via dipswitch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does a solid red status LED mean?\u003c\/strong\u003e\u003cbr\u003eA: The NPM diagnostics detect a hardware failure or configuration problem.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What do the eight CPU LEDs show?\u003c\/strong\u003e\u003cbr\u003eA: They display an error code when the status LED turns red.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which pins carry +5 VDC on the P1 connector?\u003c\/strong\u003e\u003cbr\u003eA: Pins 1 and 2 carry +5 VDC, and pins 5 and 6 carry Common.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the weight of the INNPM01?\u003c\/strong\u003e\u003cbr\u003eA: The module weighs 0.45 Kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or \u003ca href=\"https:\/\/wa.me\/8615392429628\" rel=\"noopener\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47903978225825,"sku":"INNPM01","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/INNPM01-1.jpg?v=1790063475","url":"https:\/\/www.autonexcontrol.com\/products\/innpm01-abb-network-processing-module-infi-net-controlway","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}