{"product_id":"innis01-abb-network-interface-slave-module","title":"INNIS01 ABB Network Interface Slave Module","description":"\u003ch2\u003e\u003cstrong\u003eINNIS01 ABB Network Interface Slave Module – Reliable Cnet Front-End for Symphony Systems\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eINNIS01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Network Interface Slave Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 208 kbytes RAM and 64 kbytes ROM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e +5 VDC at 900 mA, 4.50 W nominal; +15 VDC at 5 mA, 0.08 W nominal; -15 VDC at 200 mA, 3.00 W nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Capability:\u003c\/strong\u003e 62,500 nodes in the system and 250 nodes on a loop; any mix of PCU, MCS, OIS, or ICI interfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Rates:\u003c\/strong\u003e 10 Mbaud or 2 Mbaud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Occupies one slot in a standard INFI 90 OPEN module mounting unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.93 Kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Performance and Environmental Traits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution and Data Handling:\u003c\/strong\u003e The module uses 208 kbytes RAM and 64 kbytes ROM for stable communication tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response and Communication Speed:\u003c\/strong\u003e It supports \u003cspan style=\"color: #0b6e99;\"\u003e\u003cstrong\u003e10 Mbaud or 2 Mbaud\u003c\/strong\u003e\u003c\/span\u003e rates for flexible network traffic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity and Signal Integrity:\u003c\/strong\u003e Coaxial or twinaxial cables with NTCL01 termination units help maintain clean signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range and Environmental Tolerance:\u003c\/strong\u003e Install the module in a controlled cabinet that follows ABB INFI 90 OPEN guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-Interference Ability:\u003c\/strong\u003e The microprocessor-based circuitry and termination units reduce noise on Cnet links.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e The module covers node-to-node communication across 62,500 system nodes and 250 loop nodes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What communication rates does the ABB INNIS01 support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 10 Mbaud or 2 Mbaud rates for Cnet communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many nodes can the INNIS01 handle in a Symphony system?\u003c\/strong\u003e\u003cbr\u003eA: The system supports 62,500 nodes, and each loop supports 250 nodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What power inputs does this network interface slave module need?\u003c\/strong\u003e\u003cbr\u003eA: It needs +5 VDC at 900 mA, +15 VDC at 5 mA, and -15 VDC at 200 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which termination unit works with the INNIS01?\u003c\/strong\u003e\u003cbr\u003eA: It connects to Cnet through an NTCL01 termination unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What cable types connect the nodes to Cnet?\u003c\/strong\u003e\u003cbr\u003eA: Coaxial or twinaxial cables connect the termination units on each node.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How much memory does the INNIS01 module have?\u003c\/strong\u003e\u003cbr\u003eA: It has 208 kbytes RAM and 64 kbytes ROM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I mount the INNIS01?\u003c\/strong\u003e\u003cbr\u003eA: It occupies one slot in a standard INFI 90 OPEN module mounting unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the weight of the INNIS01?\u003c\/strong\u003e\u003cbr\u003eA: The module weighs 0.93 Kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or \u003ca href=\"https:\/\/wa.me\/8615392429628\" rel=\"noopener\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47903968559265,"sku":"INNIS01","price":216.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/INNIS01.jpg?v=1790062995","url":"https:\/\/www.autonexcontrol.com\/products\/innis01-abb-network-interface-slave-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}