{"product_id":"imaso01-abb-infi-90-analog-output-slave-module-14-channel","title":"IMASO01 ABB Infi 90 Analog Output Slave Module - 14-Channel","description":"\u003ch2\u003e\u003cstrong\u003eIMASO01 ABB Infi 90 Analog Output Slave Module – 14-Channel Process Control Interface\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIMASO01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Infi 90 Analog Output Slave Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e Fourteen separate analog signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signals:\u003c\/strong\u003e \u003cspan style=\"color: #0b6e99;\"\u003e\u003cstrong\u003e4 to 20 mA or 1 to 5 VDC\u003c\/strong\u003e\u003c\/span\u003e, set by module configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Unit:\u003c\/strong\u003e NTDI01 with dipshunts for output configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e INFI 90 Process Management System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Role:\u003c\/strong\u003e Slave I\/O module; master modules handle control functions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e Front-panel LED for power, enable, and fault states\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus LED Indicators\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid Green:\u003c\/strong\u003e Module is enabled and communicating with the master module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff:\u003c\/strong\u003e No power is present, or the module is not enabled.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid Red:\u003c\/strong\u003e Bus fault timer error or time out has occurred.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Performance and Environmental Traits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Range:\u003c\/strong\u003e The module delivers 4 to 20 mA or 1 to 5 VDC for process control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution and Accuracy:\u003c\/strong\u003e Fourteen independent analog channels give fine control over field devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e The slave module responds to master module commands in real time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity and Signal Integrity:\u003c\/strong\u003e NTDI01 termination and dipshunts keep output signals stable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Install the module in a controlled cabinet that follows ABB INFI 90 guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-Interference Ability:\u003c\/strong\u003e Proper grounding and shielded field wiring reduce noise on analog outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRead the IMASO01 instruction manual before you install or operate the module.\u003c\/li\u003e\n\u003cli\u003eMount the module in a compatible INFI 90 module mounting unit slot.\u003c\/li\u003e\n\u003cli\u003eConnect the module to an NTDI01 termination unit for field wiring.\u003c\/li\u003e\n\u003cli\u003eSet the dipshunts on the NTDI01 to select 4 to 20 mA or 1 to 5 VDC output.\u003c\/li\u003e\n\u003cli\u003eWire the fourteen analog outputs to the correct process field devices.\u003c\/li\u003e\n\u003cli\u003eCheck the status LED after power-up to confirm green communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB \u003cstrong\u003eIMASO01\u003c\/strong\u003e Infi 90 Analog Output Slave Module\u003c\/li\u003e\n\u003cli\u003e1 x Protective shipping carton\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static bag\u003c\/li\u003e\n\u003cli\u003e1 x Quick reference packing slip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock:\u003c\/strong\u003e We keep this item in stock for fast order handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e We ship within 5 days after we confirm your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCouriers:\u003c\/strong\u003e We use FedEx, UPS, and DHL for global delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReturns:\u003c\/strong\u003e You can return the item within 30 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e The product is brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many analog outputs does the ABB IMASO01 provide?\u003c\/strong\u003e\u003cbr\u003eA: It provides fourteen separate analog output signals for process control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What output signals does the IMASO01 support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 4 to 20 mA or 1 to 5 VDC, depending on module configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which termination unit works with the IMASO01?\u003c\/strong\u003e\u003cbr\u003eA: The module uses an NTDI01 termination unit with dipshunts for output setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does a solid green LED mean on the IMASO01?\u003c\/strong\u003e\u003cbr\u003eA: The module is enabled and communicating with the master module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does a solid red LED indicate?\u003c\/strong\u003e\u003cbr\u003eA: A bus fault timer error or time out has occurred on the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does an off LED mean?\u003c\/strong\u003e\u003cbr\u003eA: The module has no power, or it is not enabled.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What role does the IMASO01 play in the INFI 90 system?\u003c\/strong\u003e\u003cbr\u003eA: It is a slave I\/O module that outputs analog signals while master modules control the process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I change the output type after installation?\u003c\/strong\u003e\u003cbr\u003eA: Yes, you can change the dipshunts on the NTDI01 to select the output type.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or \u003ca href=\"https:\/\/wa.me\/8615392429628\" rel=\"noopener\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":47903968624801,"sku":"IMASO01","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IMASO01_409309be-5521-4b84-9b92-f3dbe76d7fac.jpg?v=1790063234","url":"https:\/\/www.autonexcontrol.com\/products\/imaso01-abb-infi-90-analog-output-slave-module-14-channel","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}