{"product_id":"honeywell-tc-ixl061-6-point-thermocouple-input-module","title":"Honeywell TC-IXL061 6-Point Thermocouple Input Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell TC-IXL061 Thermocouple Input Module — 6-Point Analog Input\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eTC-IXL061\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Thermocouple Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Notice:\u003c\/strong\u003e Replaced by TC\/TK-IXL062; terminal block rewiring required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Points:\u003c\/strong\u003e 6 channels plus 1 cold junction channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Voltage Ranges:\u003c\/strong\u003e -12 mV to +78 mV; -12 mV to +30 mV (high resolution)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Thermocouple Types:\u003c\/strong\u003e B, E, J, K, R, S, T, N, C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16 bits (1.4 µV typical); 0.70 µV on high resolution range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy (-12 mV to +78 mV Range):\u003c\/strong\u003e 0.1% FSR ±90 µV at 25℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy (-12 mV to +30 mV Range):\u003c\/strong\u003e 0.1% FSR ±42 µV at 25℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy (Cold Junction Sensor):\u003c\/strong\u003e Local CJ sensor error from ±0.3 to ±3.0℃ depending on channel; remote CJ sensor error ±0.3℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e 120 dB @ 60 Hz, 100 dB @ 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Update Rate for All Channels:\u003c\/strong\u003e 50 milliseconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSettling Time to 5% of Full Scale:\u003c\/strong\u003e Less than 80 milliseconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Circuit Detection:\u003c\/strong\u003e Open TC detection time 5 seconds typical; upscale reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Bandwidth:\u003c\/strong\u003e 0 to 15 Hz (-3 db)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Mode Noise Rejection:\u003c\/strong\u003e 60 dB @ 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRFI Immunity:\u003c\/strong\u003e Error of less than 2.0% of range at 10 V\/m, 27 to 1000 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Capability:\u003c\/strong\u003e 120 VAC\/VDC continuous at 25℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Offset Drift with Temperature:\u003c\/strong\u003e 0.5 µV\/℃ typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGain Drift with Temperature:\u003c\/strong\u003e 65 ppm\/℃ typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 4.3 W max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e See Module Power Consumption Data, page 46\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpare CJR Thermistor Model Number:\u003c\/strong\u003e TC-CJRT01 (part no. 51109433-100)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage — Channel to Channel:\u003c\/strong\u003e 100% tested at 2546 VDC for 1s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage — User to System:\u003c\/strong\u003e 100% tested at 2546 VDC for 1s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Terminal Blocks:\u003c\/strong\u003e TC-TBNH, 20-position terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance and Environmental Durability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module achieves \u003cspan style=\"color: #0b6e99;\"\u003e\u003cstrong\u003e0.1% FSR accuracy at 25℃\u003c\/strong\u003e\u003c\/span\u003e across both input voltage ranges.\u003c\/li\u003e\n\u003cli\u003eEach channel provides \u003cspan style=\"color: #0b6e99;\"\u003e\u003cstrong\u003egalvanic isolation tested at 2546 VDC for one second\u003c\/strong\u003e\u003c\/span\u003e between channel and system.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eTC-IXL061\u003c\/strong\u003e survives continuous 120 VAC\/VDC overvoltage at 25℃ without damage.\u003c\/li\u003e\n\u003cli\u003eCommon mode rejection reaches 120 dB at 60 Hz for stable readings in noisy plants.\u003c\/li\u003e\n\u003cli\u003eRFI immunity keeps error below 2.0% of range even at 10 V\/m from 27 to 1000 MHz.\u003c\/li\u003e\n\u003cli\u003eTypical input offset drift stays at 0.5 µV\/℃, while gain drift remains at 65 ppm\/℃.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module in a Honeywell I\/O rack that supports the TC-IXL061 thermocouple input series.\u003c\/li\u003e\n\u003cli\u003eUse the TC-TBNH 20-position terminal block for field wiring and secure each connection firmly.\u003c\/li\u003e\n\u003cli\u003eRewire the terminal block when replacing this module with the TC\/TK-IXL062 version.\u003c\/li\u003e\n\u003cli\u003eUse a new pre-wire cable when your system relies on an RTP (Remote Termination Panel).\u003c\/li\u003e\n\u003cli\u003ePlace the chassis inside a NEMA 4 or NEMA 12 enclosure to hold ±3℃ reference junction compensation.\u003c\/li\u003e\n\u003cli\u003eSize the enclosure at roughly 24 in. wide, 20 in. high, and 8 in. deep (610 mm × 508 mm × 203 mm).\u003c\/li\u003e\n\u003cli\u003eRoute thermocouple wiring away from high-voltage lines to preserve noise rejection and accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Honeywell TC-IXL061 Thermocouple Input Module\u003c\/li\u003e\n\u003cli\u003e1 × TC-TBNH 20-position terminal block\u003c\/li\u003e\n\u003cli\u003e1 × Anti-static protective bag\u003c\/li\u003e\n\u003cli\u003e1 × Protective foam packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship with FedEx, UPS, and DHL to most international destinations.\u003c\/li\u003e\n\u003cli\u003eOur team dispatches in-stock items within 5 days after order confirmation.\u003c\/li\u003e\n\u003cli\u003eYou may request a return within 30 days under our standard return policy.\u003c\/li\u003e\n\u003cli\u003eAll units are brand new and original from the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the replacement model for the TC-IXL061?\u003c\/strong\u003e\u003cbr\u003eA: Honeywell replaced it with the TC\/TK-IXL062, which needs terminal block rewiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which thermocouple types does this module support?\u003c\/strong\u003e\u003cbr\u003eA: It supports B, E, J, K, R, S, T, N, and C thermocouple types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What input voltage ranges does the TC-IXL061 offer?\u003c\/strong\u003e\u003cbr\u003eA: It provides -12 mV to +78 mV and a high resolution -12 mV to +30 mV range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What resolution does the module deliver?\u003c\/strong\u003e\u003cbr\u003eA: It offers 16 bits (1.4 µV typical) and 0.70 µV on the high resolution range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast does the module update all channels?\u003c\/strong\u003e\u003cbr\u003eA: The module updates all channels in 50 milliseconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the open thermocouple detection time?\u003c\/strong\u003e\u003cbr\u003eA: It detects an open thermocouple in 5 seconds typical with an upscale reading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which terminal block fits this module?\u003c\/strong\u003e\u003cbr\u003eA: The TC-TBNH 20-position terminal block connects directly to the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the overvoltage capability?\u003c\/strong\u003e\u003cbr\u003eA: It handles 120 VAC\/VDC continuous at 25℃.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What spare cold junction thermistor should I order?\u003c\/strong\u003e\u003cbr\u003eA: Order the TC-CJRT01 thermistor, part number 51109433-100.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48064174325921,"sku":"TC-IXL061","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/TC-IXL061.jpg?v=1791881193","url":"https:\/\/www.autonexcontrol.com\/products\/honeywell-tc-ixl061-6-point-thermocouple-input-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}