{"product_id":"fs-tsfire-1624-honeywell-field-termination-assembly","title":"FS-TSFIRE-1624 Honeywell Field Termination Assembly","description":"\u003ch2\u003e\n\u003cstrong\u003eHoneywell FS-TSFIRE-1624 Safe Fire Detector Input FTA Module\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e FS-TSFIRE-1624\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TUV, UL, CSA, FM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 V DC external (+25% \/ -15%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e Max 570 mA (with EOL), Typical 70 mA (no load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 16 independent channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Voltage:\u003c\/strong\u003e Typically 20.5 V DC with EOL resistor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Resistance:\u003c\/strong\u003e 680 Ω ±5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Current:\u003c\/strong\u003e 35 mA at 24 V DC supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Specs:\u003c\/strong\u003e Operates from 17 – 39 V DC, ~8.5 mA at 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp Range:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Rating:\u003c\/strong\u003e Suitable for Groups A, B, C, D hazardous areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity:\u003c\/strong\u003e Meets industrial electromagnetic compatibility standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Specs (H₂ Areas):\u003c\/strong\u003e Max inductance 60 mH, Max capacitance 0.3 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Specs (Non-H₂):\u003c\/strong\u003e Max inductance 230 mH, Max capacitance 7 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wire Resistance:\u003c\/strong\u003e Recommended \u0026lt; 100 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd-of-Line Resistor:\u003c\/strong\u003e 4.7kΩ ±5% (0.25W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the FS-TSFIRE-1624 module brand new and genuine?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply every \u003cstrong\u003eHoneywell FS-TSFIRE-1624\u003c\/strong\u003e as \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003ebrand new and 100% genuine\u003c\/strong\u003e\u003c\/span\u003e in original packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What power supply is required for the module?\u003c\/strong\u003e\u003cbr\u003eA: It requires a \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e24 V DC power source\u003c\/strong\u003e\u003c\/span\u003e, with an operating range of 20.4V to 30V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this product in stock for immediate shipment?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we maintain \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003eregular stock\u003c\/strong\u003e\u003c\/span\u003e for fast order processing and shipping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What are the shipping time and carrier options?\u003c\/strong\u003e\u003cbr\u003eA: We typically \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003eship within 5 days\u003c\/strong\u003e\u003c\/span\u003e using DHL, FedEx, or UPS courier services.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the module support resetting multiple detectors at once?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it features a \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003eglobal reset function\u003c\/strong\u003e\u003c\/span\u003e for all connected fire detectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information for Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: \u003cstrong\u003eNexAuto Technology Limited\u003c\/strong\u003e : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45664887079073,"sku":"FS-TSFIRE-1624","price":223.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/FS-TSFIRE-1624.jpg?v=1782286025","url":"https:\/\/www.autonexcontrol.com\/products\/fs-tsfire-1624-honeywell-field-termination-assembly","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}