{"product_id":"fc-tidi-1624-field-termination-module-honeywell","title":"FC-TIDI-1624 Field Termination Module Honeywell","description":"\u003ch2\u003e\u003cstrong\u003eReliable Signal Acquisition with the Honeywell FC-TIDI-1624 Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functions and System Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eTIDI-1624\u003c\/strong\u003e acts as the primary interface between field devices and system cables.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e86c1;\"\u003eIt provides sixteen isolated input channels for 24V DC signals.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe module connects to one or more SDI-1624 input modules via SICC-0001\/Lx cables.\u003c\/li\u003e\n\u003cli\u003eThis design supports redundant system configurations for higher availability.\u003c\/li\u003e\n\u003cli\u003eIt translates field wiring connections to the control system's interconnection standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eComplete Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Input Channels:\u003c\/strong\u003e 16 isolated channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e 24 Volts DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePick-up Voltage:\u003c\/strong\u003e 17.5V DC minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-out Voltage:\u003c\/strong\u003e 2.8V DC maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Voltage:\u003c\/strong\u003e 47.5 Volts DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical Input Current:\u003c\/strong\u003e 9 mA at 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Switching Frequency:\u003c\/strong\u003e 20 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Polarity Protection:\u003c\/strong\u003e Yes, via series diode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Reverse Voltage:\u003c\/strong\u003e 300 Volts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage (Input to Output\/Input):\u003c\/strong\u003e 1000V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Life:\u003c\/strong\u003e 1,000,000 operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Life:\u003c\/strong\u003e 10,000,000 operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TUV, UL, CSA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 265 × 70 × 48 mm (L × W × H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e TS32 \/ TS35 DIN rail (× 7.5)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals:\u003c\/strong\u003e Screw type, max 2.5 mm² (AWG 14) wire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Are these modules original Honeywell products?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we provide only \u003cspan style=\"color: #2e86c1;\"\u003eauthentic and new\u003c\/span\u003e Honeywell equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the isolation rating between channels?\u003c\/strong\u003e\u003cbr\u003eA: The module provides \u003cspan style=\"color: #2e86c1;\"\u003e1000V AC isolation\u003c\/span\u003e between input channels and to output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What wire size can I use for field connections?\u003c\/strong\u003e\u003cbr\u003eA: The screw terminals accept up to \u003cspan style=\"color: #2e86c1;\"\u003e2.5 mm² (AWG 14)\u003c\/span\u003e wire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can it handle voltage spikes or reverse polarity?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it has \u003cspan style=\"color: #2e86c1;\"\u003ereverse polarity protection and handles up to 300V reverse voltage\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your shipping and return policy?\u003c\/strong\u003e\u003cbr\u003eA: We ship in 5 days and offer a \u003cspan style=\"color: #2e86c1;\"\u003e30-day return\u003c\/span\u003e for unused items.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003cbr\u003ePartner \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45662905434273,"sku":"FC-TIDI-1624","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/FC-TIDI-1624.jpg?v=1781508620","url":"https:\/\/www.autonexcontrol.com\/products\/fc-tidi-1624-field-termination-module-honeywell","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}