{"product_id":"evf9327-cvv003-lenze-9300-vector-15-kw-frequency-inverter","title":"EVF9327-CVV003 Lenze 9300 Vector 15 kW Frequency Inverter","description":"\u003ch2\u003e\u003cstrong\u003eLenze EVF9327-CVV003 9300 Vector Frequency Inverter – 15 kW Cold-Plate Drive\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Lenze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eEVF9327-CVV003\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e 9300 vector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated motor power:\u003c\/strong\u003e 15.0 kW for a 4-pole asynchronous motor at 3 AC 400 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput current:\u003c\/strong\u003e 32.0 A nominal at 8 kHz chopper frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. output current:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e48.0 A for 60 s\u003c\/strong\u003e\u003c\/span\u003e with 150% overload capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput power:\u003c\/strong\u003e 22.2 kVA nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChopper frequency:\u003c\/strong\u003e adjustable to 2, 4, 8 or 16 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl modes:\u003c\/strong\u003e V\/f characteristic control and sensorless vector control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical and Frequency Range\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 3\/PE AC 320 to 528 V nominal, 45 to 65 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternative DC supply:\u003c\/strong\u003e 460 to 740 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput frequency at 16 kHz:\u003c\/strong\u003e 0 to 600 Hz maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput frequency at 8 kHz:\u003c\/strong\u003e 0 to 300 Hz maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput frequency at 2 kHz:\u003c\/strong\u003e 0 to 150 Hz maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput frequency at 4 kHz:\u003c\/strong\u003e 0 to 150 Hz for sizes 9321–9333\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower loss:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e430 W\u003c\/strong\u003e\u003c\/span\u003e heat dissipation per official rated data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and Expansion\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in ports:\u003c\/strong\u003e AIF automation interface (X1), system bus CAN (X4), incremental encoder input (X8)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN system bus:\u003c\/strong\u003e integrated for multi-drive coordination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFieldbus modules:\u003c\/strong\u003e pluggable via AIF interface, including LECOM-A\/B, PROFIBUS DP, CANopen, DeviceNet, INTERBUS and LON\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard configuration:\u003c\/strong\u003e no integrated fieldbus module; expansion depends on the selected plug-in module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Tolerance and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0 to +40 °C rated; +40 to +50 °C with 2.5% output current derating per K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -25 to +55 °C; transport range -25 to +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e average 85% RH without condensation, climatic class 3K3 per EN 50178\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection rating:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/span\u003e (NEMA 1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise immunity:\u003c\/strong\u003e designed for industrial electromagnetic environments per Lenze 9300 vector documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Dimensions and Mounting Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H×W×D):\u003c\/strong\u003e 350 × 234 × 171 mm for the cold-plate body\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 13 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting design:\u003c\/strong\u003e cold-plate push-through design without an integrated fan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling requirement:\u003c\/strong\u003e external cooler with thermal resistance per the official Lenze manual\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation note:\u003c\/strong\u003e mount the cold plate to a suitable heat sink and verify airflow or liquid cooling before commissioning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring note:\u003c\/strong\u003e connect supply, motor and encoder cables according to the 9300 vector terminal assignment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Lenze \u003cstrong\u003eEVF9327-CVV003\u003c\/strong\u003e frequency inverter\u003c\/li\u003e\n\u003cli\u003e1 × cold-plate mounting accessory set as supplied by Lenze\u003c\/li\u003e\n\u003cli\u003e1 × quick reference or terminal labeling document\u003c\/li\u003e\n\u003cli\u003ePackaging does not include certification documents or a 12-month warranty statement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCourier options:\u003c\/strong\u003e FedEx, UPS and DHL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch time:\u003c\/strong\u003e within 5 days after order confirmation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock status:\u003c\/strong\u003e brand-new original units available in stock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLifecycle and Migration Note\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus:\u003c\/strong\u003e legacy Lenze order code listed in official product information and previous-products documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMigration path:\u003c\/strong\u003e Lenze lists the 9300 series within the i950 migration set via the i950 PROFIBUS module and L_ICIP library\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement caution:\u003c\/strong\u003e no drop-in same-order-code replacement exists; verify compatibility before upgrading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudit status:\u003c\/strong\u003e OFFICIAL_VERIFIED, last verified 2026-10\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the overload capacity of the EVF9327-CVV003?\u003c\/strong\u003e\u003cbr\u003eA: It provides 150% rated torque for 60 s, with a maximum output current of 48.0 A for 60 s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this drive include an integrated cooling fan?\u003c\/strong\u003e\u003cbr\u003eA: No, the cold-plate design requires an external cooler with thermal resistance specified in the official Lenze manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which fieldbus protocols can I use with this inverter?\u003c\/strong\u003e\u003cbr\u003eA: You can add pluggable AIF modules for LECOM-A\/B, PROFIBUS DP, CANopen, DeviceNet, INTERBUS or LON.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What output frequency can I reach at 16 kHz chopper frequency?\u003c\/strong\u003e\u003cbr\u003eA: The output frequency range reaches 0 to 600 Hz maximum at 16 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range with derating?\u003c\/strong\u003e\u003cbr\u003eA: The rated range is 0 to +40 °C; from +40 to +50 °C you must derate output current by 2.5% per K.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the EVF9327-CVV003 available as a new original unit?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we offer brand-new original units, ship within 5 days and support 30-day returns.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":48779176018081,"sku":"EVF9327-CVV003","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/EVF9327-CVV003.jpg?v=1793783347","url":"https:\/\/www.autonexcontrol.com\/products\/evf9327-cvv003-lenze-9300-vector-15-kw-frequency-inverter","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}