{"product_id":"ds200upsag1agd-ge-mark-v-power-supply-board","title":"DS200UPSAG1AGD GE Mark V Power Supply Board","description":"\u003ch2\u003e\u003cstrong\u003eDS200UPSAG1AGD GE Mark V UC200 Power Supply Board – Product Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE General Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eDS200UPSAG1AGD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e UC200 Power Supply Board \/ LAN Circuit Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Acronym:\u003c\/strong\u003e UPSA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Type:\u003c\/strong\u003e Normal Assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Grouping:\u003c\/strong\u003e Group 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevision:\u003c\/strong\u003e A-rated functional product revision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacture Location:\u003c\/strong\u003e Domestic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 24 VDC nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e DC to 1 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12-bit analog-to-digital conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±0.1% full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e 10 mV per unit input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e High EMI\/RFI shielding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Hardware Components\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0000ff;\"\u003eOne reset button\u003c\/span\u003e for manual system recovery\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0000ff;\"\u003eThree fuses\u003c\/span\u003e protecting against over-current conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0000ff;\"\u003eOne LED indicator\u003c\/span\u003e for status monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0000ff;\"\u003eThree 9-pin connectors\u003c\/span\u003e for signal and power interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0000ff;\"\u003eMultiple capacitors\u003c\/span\u003e for high-voltage storage and release\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0000ff;\"\u003eTest points\u003c\/span\u003e for diagnostic measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCapacitor Safety and Handling\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe capacitors store high-voltage current during normal operation.\u003c\/li\u003e\n\u003cli\u003eOperators typically remain unaware of this charging cycle.\u003c\/li\u003e\n\u003cli\u003eThe high voltage poses no risk during standard use.\u003c\/li\u003e\n\u003cli\u003eA defective board may retain a dangerous charge after shutdown.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003eWait 30 seconds after power removal before touching the board.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe high-voltage current exits the capacitors within 30 seconds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFuse Protection and Replacement\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe three fuses protect board components from over-current damage.\u003c\/li\u003e\n\u003cli\u003eAn irregular current causes one or more fuses to blow.\u003c\/li\u003e\n\u003cli\u003eThe fuse shuts down the circuit it protects.\u003c\/li\u003e\n\u003cli\u003eChecking fuses is a simple visual task.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003eEach fuse connector requires a fuse with the proper rating.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eRefer to factory instructions for the correct fuse rating.\u003c\/li\u003e\n\u003cli\u003ePull the fuse out to remove it.\u003c\/li\u003e\n\u003cli\u003ePress the fuse into the connector to install it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower down the Mark V control system completely.\u003c\/li\u003e\n\u003cli\u003eWait 30 seconds for capacitor discharge.\u003c\/li\u003e\n\u003cli\u003eLabel all cables before disconnection.\u003c\/li\u003e\n\u003cli\u003eRemove the defective board from its rack.\u003c\/li\u003e\n\u003cli\u003eAlign the new \u003cstrong\u003eDS200UPSAG1AGD\u003c\/strong\u003e board with the slot guides.\u003c\/li\u003e\n\u003cli\u003eSecure the board with mounting screws.\u003c\/li\u003e\n\u003cli\u003eReconnect all three 9-pin connectors.\u003c\/li\u003e\n\u003cli\u003eVerify fuse ratings match factory specifications.\u003c\/li\u003e\n\u003cli\u003eRestore power and check the LED indicator.\u003c\/li\u003e\n\u003cli\u003ePress the reset button if the system requires initialization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x GE \u003cstrong\u003eDS200UPSAG1AGD\u003c\/strong\u003e UC200 Power Supply Board\u003c\/li\u003e\n\u003cli\u003e3 x Fuses (proper rating installed)\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static protective bag\u003c\/li\u003e\n\u003cli\u003e1 x Shock-absorbing foam packaging\u003c\/li\u003e\n\u003cli\u003e1 x Cardboard shipping box\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Methods\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx Express for urgent deliveries\u003c\/li\u003e\n\u003cli\u003eUPS Worldwide Saver for reliable transport\u003c\/li\u003e\n\u003cli\u003eDHL Express for international shipments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the condition of this product?\u003c\/strong\u003e\u003cbr\u003eA: We offer brand new original products only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have stock available?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep this item in stock for immediate order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: We dispatch orders within 5 days of payment confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping carriers do you use?\u003c\/strong\u003e\u003cbr\u003eA: We use DHL, FedEx, and UPS for all deliveries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support returns within 30 days of delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The board operates from -20°C to +70°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long should I wait before touching the board after power off?\u003c\/strong\u003e\u003cbr\u003eA: Wait at least 30 seconds for capacitor discharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I replace fuses myself?\u003c\/strong\u003e\u003cbr\u003eA: Yes, pull out the old fuse and press in a new one with the correct rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What connectors does this board use?\u003c\/strong\u003e\u003cbr\u003eA: It features three 9-pin connectors for interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the functional acronym for this board?\u003c\/strong\u003e\u003cbr\u003eA: The functional acronym is UPSA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47893054652577,"sku":"DS200UPSAG1AGD","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/DS200UPSAG1AGD.jpg?v=1789891705","url":"https:\/\/www.autonexcontrol.com\/products\/ds200upsag1agd-ge-mark-v-power-supply-board","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}