{"product_id":"ds200shvmg1afe-ge-mark-v-scr-high-voltage-interface-board","title":"DS200SHVMG1AFE GE Mark V SCR High Voltage Interface Board","description":"\u003ch2\u003e\u003cstrong\u003eDS200SHVMG1AFE SCR High Voltage M-Frame Interface Board – GE Mark V Series\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e General Electric (GE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eDS200SHVMG1AFE\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e SCR High Voltage M-Frame Interface Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e General Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstruction Manual:\u003c\/strong\u003e GEI-100174A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Acronym:\u003c\/strong\u003e SHVM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Coating:\u003c\/strong\u003e Normal Coating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevision Quantity:\u003c\/strong\u003e 3 Revisions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMark V Series Grouping:\u003c\/strong\u003e Group 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e -500 mV to +500 mV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Frequency Range:\u003c\/strong\u003e 0 to 500 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Relay Channels:\u003c\/strong\u003e 12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Voltage:\u003c\/strong\u003e 28 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN-Rail Mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Attenuation:\u003c\/strong\u003e Jumper-Selectable 10:1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Line Voltage Attenuation Bypass:\u003c\/strong\u003e 240–600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnology:\u003c\/strong\u003e Surface Mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eACCT Secondary Current Rating:\u003c\/strong\u003e 144 mA Maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 15.9 cm High × 17.8 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Components and Signal Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Bridge Shunt Isolator Circuits:\u003c\/strong\u003e Floating VCO circuits convert shunt signals from -500 mV to +500 mV into 0–500 kHz outputs for the DCFB board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current Transformers (ACCTs):\u003c\/strong\u003e The board provides jumper-selectable 10:1 attenuation for phase A and phase C AC line currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eACCT Attenuation Rule:\u003c\/strong\u003e Select 10:1 attenuation when the main line ACCT secondary current exceeds 144 mA; bypass it when current stays below this rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Voltage Attenuators (L1, L2, L3):\u003c\/strong\u003e These attenuate AC line voltage based on generator field ratings and magnitude.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Voltage Bypass Rule:\u003c\/strong\u003e Bypass the attenuators for a 240–600 V main AC line and include them for a 601–1000 V main AC line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Bridge Voltages (P1 and P2):\u003c\/strong\u003e Resistor strings attenuate DC voltage based on field voltage ratings and scale the DC bus voltage feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage-Limiting Components:\u003c\/strong\u003e Diodes, resistors, and integrated circuits protect the board during operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eJumper Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe board includes \u003cstrong\u003e17 jumpers\u003c\/strong\u003e for attenuation and configuration settings.\u003c\/li\u003e\n\u003cli\u003eJumpers \u003cstrong\u003eJP1–JP8\u003c\/strong\u003e share the same function: they select or bypass 10:1 attenuation for phase A and phase C current transformers.\u003c\/li\u003e\n\u003cli\u003eSet JP1–JP8 to the same position for correct attenuation behavior.\u003c\/li\u003e\n\u003cli\u003eMost other jumpers select different line attenuation strings for the board configuration.\u003c\/li\u003e\n\u003cli\u003eRefer to the GEI-100174A manual for the exact placement and function of each jumper.\u003c\/li\u003e\n\u003cli\u003eThe board also features wiring plugs and stab connectors as part of its customization strategy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWait a few minutes after power removal for the capacitors to discharge before touching the board.\u003c\/li\u003e\n\u003cli\u003eMount the \u003cstrong\u003eDS200SHVMG1AFE\u003c\/strong\u003e board on a DIN rail inside the drive enclosure.\u003c\/li\u003e\n\u003cli\u003eSet the JP1–JP8 jumpers to match your ACCT secondary current and attenuation requirements.\u003c\/li\u003e\n\u003cli\u003eConfigure the line voltage and DC bridge voltage jumpers based on your main AC line rating.\u003c\/li\u003e\n\u003cli\u003eConnect the signal wires between the SCR bridge, the power supply board, and the power connect card.\u003c\/li\u003e\n\u003cli\u003eVerify all jumper settings against the GEI-100174A manual before powering up the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003eDS200SHVMG1AFE\u003c\/strong\u003e SCR High Voltage M-Frame Interface Board\u003c\/li\u003e\n\u003cli\u003e1 × Static-sensitive packaging bag\u003c\/li\u003e\n\u003cli\u003e1 × Protective foam packaging\u003c\/li\u003e\n\u003cli\u003e1 × Cardboard shipping box\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship via FedEx, UPS, and DHL to worldwide destinations.\u003c\/li\u003e\n\u003cli\u003eWe dispatch orders within 5 business days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003eWe accept returns within 30 days of delivery under our return policy.\u003c\/li\u003e\n\u003cli\u003eAll units are brand new and original.\u003c\/li\u003e\n\u003cli\u003eOur stock is available for immediate order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the input voltage range of the DS200SHVMG1AFE?\u003c\/strong\u003e\u003cbr\u003eA: The board converts shunt signals ranging from -500 mV to +500 mV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What output frequency does the board produce?\u003c\/strong\u003e\u003cbr\u003eA: It produces differential frequency outputs from 0 to 500 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: When should I select the 10:1 current attenuation?\u003c\/strong\u003e\u003cbr\u003eA: Select it when the main line ACCT secondary current exceeds 144 mA; otherwise bypass it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The board operates reliably from -30°C to +65°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many jumpers does the board have?\u003c\/strong\u003e\u003cbr\u003eA: It has 17 jumpers, with JP1–JP8 controlling phase A and phase C attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the power supply voltage?\u003c\/strong\u003e\u003cbr\u003eA: The board uses a 28 V DC power supply voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the DS200SHVMG1AFE in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we have this item in stock and ready to ship.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does shipping take?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 business days via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support returns within 30 days of delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: NexAuto Technology Limited – \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48151782293665,"sku":"DS200SHVMG1AFE","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/DS200SHVMG1AFE.jpg?v=1792485601","url":"https:\/\/www.autonexcontrol.com\/products\/ds200shvmg1afe-ge-mark-v-scr-high-voltage-interface-board","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}