{"product_id":"ds200ptctg1baa-general-electric-mark-v-pt-ct-signal-conditioner-board","title":"DS200PTCTG1BAA General Electric Mark V PT CT Signal Conditioner Board","description":"\u003ch2\u003e\u003cstrong\u003eDS200PTCTG1BAA Potential Transformer Current Transformer – General Electric Mark V Signal Conditioner Board\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003eGeneral Electric\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eDS200PTCTG1BAA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003eMark V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e PT and CT Signal Conditioner Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Acronym:\u003c\/strong\u003e PTCT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Description:\u003c\/strong\u003e Signal Conditioner Card\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e +5 V dc, 6 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 120 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Voltage:\u003c\/strong\u003e 24 V dc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower System Frequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Relay Channels:\u003c\/strong\u003e 12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN-rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnology:\u003c\/strong\u003e Surface mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-30 to +65°C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 15.9 cm high x 17.8 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Coating:\u003c\/strong\u003e Normal Coating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevision Quantity:\u003c\/strong\u003e 3 Revisions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Type:\u003c\/strong\u003e Normal Assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMark V Series Grouping:\u003c\/strong\u003e Group 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Functions and Signal Conditioning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Isolation:\u003c\/strong\u003e The board provides galvanic isolation between high voltage circuits and low voltage control circuits. This design protects sensitive equipment and personnel from dangerous electrical exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Protection:\u003c\/strong\u003e The \u003cstrong\u003eDS200PTCTG1BAA\u003c\/strong\u003e safeguards itself and downstream devices from transient overvoltages. This protection supports stable operation in demanding turbine control environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmplification:\u003c\/strong\u003e It raises incoming signal levels to an optimal range for A\/D converters and other processing hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiltering:\u003c\/strong\u003e The board removes noise and unwanted frequency components. This process delivers a clean and stable signal for control and measurement tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearization:\u003c\/strong\u003e The output signal remains directly proportional to the input signal across the specified operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog-to-Digital Conversion:\u003c\/strong\u003e It converts analog PT and CT signals into digital format for digital protection relays or data acquisition systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration and Adjustment:\u003c\/strong\u003e Built-in potentiometers or digital settings calibrate gain, offset, and other parameters. This feature ensures accurate signal processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware and Connector Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe TCCB Board plays a crucial role by accepting secondary isolation transformers through the attached JKK connector.\u003c\/li\u003e\n\u003cli\u003eThe assembly uses voltage-limiting components such as Mark V rectifiers, capacitors, diodes, and integrated circuits.\u003c\/li\u003e\n\u003cli\u003eThis signal conditioner board includes 1 terminal block with terminals for 72 signal wires.\u003c\/li\u003e\n\u003cli\u003eIt also contains 1 50-pin connector for system integration.\u003c\/li\u003e\n\u003cli\u003eTerminal block IDs include OUT2, OUT1, COM1, COM2, P15, SO21, and L23.\u003c\/li\u003e\n\u003cli\u003eThe board also provides terminal posts for 6 signal wires.\u003c\/li\u003e\n\u003cli\u003eThe original performance specifications and dimensions reflect a B-rated primary revision, an A-rated secondary revision, and an A-rated artwork revision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Interference Reduction Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePlan cable routing carefully before you install the drive and connect the board.\u003c\/li\u003e\n\u003cli\u003eRoute high-voltage power cables away from signal cables whenever possible.\u003c\/li\u003e\n\u003cli\u003eBundle power cables together and bundle signal cables together as separate groups.\u003c\/li\u003e\n\u003cli\u003eLimit the length where power and signal cables run in parallel.\u003c\/li\u003e\n\u003cli\u003eKeep signal and power cables further apart when parallel runs are longer.\u003c\/li\u003e\n\u003cli\u003eAllow closer spacing when parallel runs are shorter.\u003c\/li\u003e\n\u003cli\u003eRun signal and power cables at right angles to reduce signal exposure to interference.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables under some conditions to protect signal wires from interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance and Environmental Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e The board conditions PT and CT signals for voltage and current measurement in Mark V drive systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e It supports a 60 Hz power system frequency for compatible turbine control applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e The signal conditioner adapts low-level PT and CT signals for accurate processing by control hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e The output remains proportional to the input over the specified operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e Analog-to-digital conversion prepares signals for digital relays and data acquisition systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e The board operates reliably from \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-30 to +65°C\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Normal PCB coating helps the board resist common industrial operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-Interference Ability:\u003c\/strong\u003e Proper cable routing, bundling, right-angle crossing, and shielding reduce signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse DIN-rail mounting for secure placement inside the compatible Mark V drive assembly.\u003c\/li\u003e\n\u003cli\u003eConfirm the power requirements of +5 V dc, 6 A before you connect the board.\u003c\/li\u003e\n\u003cli\u003eVerify the 120 V AC input voltage and 24 V dc power supply voltage for proper system matching.\u003c\/li\u003e\n\u003cli\u003eCheck all terminal block connections for OUT2, OUT1, COM1, COM2, P15, SO21, and L23.\u003c\/li\u003e\n\u003cli\u003eInspect the 50-pin connector and JKK connector for secure attachment.\u003c\/li\u003e\n\u003cli\u003eFollow the original instructional manual for cable planning and interference control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eDS200PTCTG1BAA\u003c\/strong\u003e Potential Transformer Current Transformer board\u003c\/li\u003e\n\u003cli\u003e1 x Protective packaging for safe transit\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static wrapping for electronic component protection\u003c\/li\u003e\n\u003cli\u003e1 x Order documentation package without certificate information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe keep this item in stock and dispatch it within 5 days after order confirmation.\u003c\/li\u003e\n\u003cli\u003eWe ship by common express methods such as FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eWe support 30-day returns under our stated return policy.\u003c\/li\u003e\n\u003cli\u003eAll items are brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the model number of this General Electric board?\u003c\/strong\u003e\u003cbr\u003eA: The model number is \u003cstrong\u003eDS200PTCTG1BAA\u003c\/strong\u003e, and it belongs to the Mark V series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does this board do in a Mark V system?\u003c\/strong\u003e\u003cbr\u003eA: It scales and isolates PT and CT signals while providing auxiliary inputs and outputs for low voltage drive signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What are the power requirements?\u003c\/strong\u003e\u003cbr\u003eA: The board requires +5 V dc at 6 A, with a 24 V dc power supply voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the input voltage and frequency?\u003c\/strong\u003e\u003cbr\u003eA: The input voltage is 120 V AC, and the power system frequency is 60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The board operates from \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e-30 to +65°C\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many relay channels does it have?\u003c\/strong\u003e\u003cbr\u003eA: It has 12 relay channels for compatible control applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How does the board reduce signal interference?\u003c\/strong\u003e\u003cbr\u003eA: Proper cable routing, bundling, right-angle crossing, and shielded cables help reduce interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What connectors and terminals does it include?\u003c\/strong\u003e\u003cbr\u003eA: It includes 1 terminal block for 72 signal wires, 1 50-pin connector, and terminal posts for 6 signal wires.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the mounting type?\u003c\/strong\u003e\u003cbr\u003eA: The board uses DIN-rail mounting for installation in compatible Mark V assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this item in stock, and how fast do you ship?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep it in stock and ship within 5 days using FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information Inquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47899521581217,"sku":"DS200PTCTG1BAA","price":203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/DS200PTCTG1BAA.jpg?v=1789978058","url":"https:\/\/www.autonexcontrol.com\/products\/ds200ptctg1baa-general-electric-mark-v-pt-ct-signal-conditioner-board","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}