{"product_id":"ds200pccag8acb-power-connect-card-ge-mark-v-g8","title":"DS200PCCAG8ACB Power Connect Card GE Mark V G8","description":"\u003ch2\u003e\u003cstrong\u003eDS200PCCAG8ACB Power Connect Card – GE Mark V Series\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e General Electric (GE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eDS200PCCAG8ACB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Power Connect Card\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e General Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstruction Manual:\u003c\/strong\u003e GEI-100161B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Acronym:\u003c\/strong\u003e PCCA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Coating:\u003c\/strong\u003e Normal Coating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Revision 1:\u003c\/strong\u003e A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Revision 2:\u003c\/strong\u003e C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArtwork Revision:\u003c\/strong\u003e B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup Number:\u003c\/strong\u003e Group 8 (G8)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Span:\u003c\/strong\u003e 1–5 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Current:\u003c\/strong\u003e 0–20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnology:\u003c\/strong\u003e Surface Mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30°C to 65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 26.41 cm High × 21.33 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBoard Groups and Voltage Scaling\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe PCCA board has \u003cstrong\u003eten group numbers\u003c\/strong\u003e determined by system voltage, frame size, and power conversion method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG1, G7, and G9:\u003c\/strong\u003e Regenerative systems rated at 240–630 volts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG2, G8, and G10:\u003c\/strong\u003e Non-regenerative systems rated at 240–700 volts.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eDS200PCCAG8ACB\u003c\/strong\u003e belongs to Group 8, which serves non-regenerative systems at 240–700 volts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eJumper Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe board contains \u003cstrong\u003efour wire jumpers\u003c\/strong\u003e: JP1, JP2, WP3, and WP4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJP1 and JP2\u003c\/strong\u003e connect to the correct stab terminals (P3 through P10) based on the card group number and system voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWP3\u003c\/strong\u003e links stab terminal P2A to P2B.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWP4\u003c\/strong\u003e links stab terminal P1A to P1B.\u003c\/li\u003e\n\u003cli\u003eWP3 and WP4 determine whether the snubber capacitors connect to the same point on the power bridge as the voltage feedback channel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Components and Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Transformers:\u003c\/strong\u003e These supply gate drives to the SCR bridge for reliable switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSnubber Circuits:\u003c\/strong\u003e Low-to-medium horsepower controllers include snubber circuits to manage spikes across AC lines, the DC bus, and gate drivers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage-Limiting Components:\u003c\/strong\u003e Capacitors, resistors, transistors, and specialized integrated circuits handle voltage suppression and limitation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrum-Style Capacitors:\u003c\/strong\u003e Large silver drum-style capacitors stack across the bottom of the base circuit board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Interface:\u003c\/strong\u003e The board receives and transmits signals to the power supply board, the SCR bridge, and other drive components through multiple connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecord where the wires and cables connect on the defective board before removal.\u003c\/li\u003e\n\u003cli\u003eLabel the wires and connectors and photograph the board before removing any cables.\u003c\/li\u003e\n\u003cli\u003eNote that newer board versions may have rearranged connectors or different component colors and shapes.\u003c\/li\u003e\n\u003cli\u003eInstall the new board with confidence because compatibility is verified before delivery.\u003c\/li\u003e\n\u003cli\u003eNever pull a ribbon cable out by the ribbon itself; hold the connector on the board with one hand.\u003c\/li\u003e\n\u003cli\u003eHold the connector on the end of the ribbon cable tightly with the other hand and pull them apart.\u003c\/li\u003e\n\u003cli\u003eConfirm that all ribbon cable signals transmit and receive correctly to avoid operational reliability issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003eDS200PCCAG8ACB\u003c\/strong\u003e Power Connect Card\u003c\/li\u003e\n\u003cli\u003e1 × Anti-static protective bag\u003c\/li\u003e\n\u003cli\u003e1 × Protective foam packaging\u003c\/li\u003e\n\u003cli\u003e1 × Cardboard shipping box\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship via FedEx, UPS, and DHL to worldwide destinations.\u003c\/li\u003e\n\u003cli\u003eWe dispatch orders within 5 business days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003eWe accept returns within 30 days of delivery under our return policy.\u003c\/li\u003e\n\u003cli\u003eAll units are brand new and original.\u003c\/li\u003e\n\u003cli\u003eOur stock is available for immediate order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the main function of the DS200PCCAG8ACB?\u003c\/strong\u003e\u003cbr\u003eA: It connects the drive control circuitry to the SCR power bridge and supplies gate drives through pulse transformers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What group number does this board belong to?\u003c\/strong\u003e\u003cbr\u003eA: It belongs to Group 8, which serves non-regenerative systems rated at 240–700 volts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many wire jumpers does the board have?\u003c\/strong\u003e\u003cbr\u003eA: The board has four wire jumpers: JP1, JP2, WP3, and WP4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the input span and output voltage?\u003c\/strong\u003e\u003cbr\u003eA: The input span is 1–5 V DC and the outputs are 24 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The board operates reliably from -30°C to 65°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many channels does the board support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 6 channels with an analog output current of 0–20 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the DS200PCCAG8ACB in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we have this item in stock and ready to ship.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does shipping take?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 business days via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the return policy?\u003c\/strong\u003e\u003cbr\u003eA: We support returns within 30 days of delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: NexAuto Technology Limited – \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48151835312289,"sku":"DS200PCCAG8ACB","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/DS200PCCAG8ACB.jpg?v=1792486029","url":"https:\/\/www.autonexcontrol.com\/products\/ds200pccag8acb-power-connect-card-ge-mark-v-g8","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}